HomeMy WebLinkAboutAUTH-04-2023-194560.TIF � , CATAWBA COUNTY Case# AUTI1-04-2023-194560
ti f. . , Public Health Department Subdivision
d i Environmental Health Division PIN# 471003212178
PO Box 389,25 Government Drive,Newton,NC 28658 1,0"1'# 25
• • , v
Site Address: 1181 CATALINA CT, CATAWBA NC 28609
Name on Permit: DONALD STULL
Property Size: Acres 2.58
Directions: From HWY 150 E turn left onto Mt Pleasant Rd,turn Right on Sherrills Ford Rd,turn Left onto Molly's
Backbone Rd, Right on Monbo, Right on N. Saunders, Right on Aeromarine Blvd, Right on Catalina Ct
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 480 g.p.d.
Type of Facility: Primary Residence-
Basement? Yes Basement Plumbing? Yes Bedrooms: 4
Water Supply: Private Well Maximum Occupants: 8
Soil LIAR: 0.275 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 1,326sq ft Total Trench Length: 442 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 29 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not cut, drive, fill, or grade over septic or repair areas.
*Septic system must be 10 ft from property lines, 100 feet from wells, 15 ft from basement cuts, 5 ft from
building foundations and appurtenances, and out of right-of-ways and easements.
*The initial septic system is considered a saprolite system and must be 100 feet from wells, but the repair areas
did not have saprolite so repair can encroach to 50 ft from well.
*Install a 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface).
*Install 442 linear feet of 25%reduction system, proposed 5 lines total at 86 ft,86 ft, 90 ft, 90 ft, and 90 ft each
on contour.
*Final grade of septic area must shed surface water off and away from system.
*All gutter drains must be routed away from the septic system.
*Well should be 5 ft from property lines; 25 ft from structures; 100 ft from initial septic system; and out of right-of
-ways and easements.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LIAR: 0.275g.p.dJft2
dipcio1.1 04/27/2023 16:43
04, CATAWBA COUNTY
Case# AUTH-04-2023-194560
Public Health Department Subdivision
Environmental Health Division PIN# 471003212178
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 25
Site Address: 1181 CATALINA CT, CATAWBA NC 28609
Name on Permit: DONALD STULL
Property Size: Acres 2.58
Directions: From HWY 150 E turn left onto Mt Pleasant Rd, turn Right on Sherrills Ford Rd, turn Left onto Molly's
Backbone Rd, Right on Monbo, Right on N. Saunders, Right on Aeromarine Blvd, Right on Catalina Ct
Proposed System: 50%REDUCTION VERTICAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Seware Treatment and Disposal Systems'(l5A NCAC 18A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
% -----,,— /-.2-.._,.....
04/27/2023
Authorized State Agent Permit Issuance Date
4/27/2028
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehpemtit 04/27/2023 16:43
i
(6t4 02-20z3- 433Y4
!Pt hC + 4(
Catawba County Environmental Health oy-Zi L3-IQY.3Zv
welt oy- 7_3— I Ns-sy
dy
00.50
CI
cNi
1
Ne,
400.97 r '�>
181
..st-'
I 'Yy`
i
trt'5`r
/7
lige ,ram `r�r
: .
f
hs
< e/1"Pre'r
r 4 v.
1 'rr-Q�,✓ ti
;Ir o
a1 -
i.4 R'>•''"' •8224
,u
1rb
\ O.
7
Parcel: 471003212178, 1181 CATALINA CT tin=80ft
CATAWBA, 28609
1
This map/report product was prepared from the Catawba County,NC Oeospatiei Information Services. Catawba County has made substantial efforts
to ensure the accuracy of location and labeling information contained on this map or data on this report.Catawba County promotes and recommends
the independent verification of any data contained on this map/report product by the user.The County of Catawba,its employees,agents,and
personnel,disclaim,and shall not be held Iiiable for any and all damages,loss or liablity,whether direct,indirect or consequential which arises or may
arise from this rnaphsport product or the use thereof by any person or entity.
Copyright 2023 Catawba County NC
04/27/2023