HomeMy WebLinkAboutAUTH-04-2023-193922.TIF 144 tATAWRA(1)1gC11.
t +! lL'liclkahhl)gvr,tmcnt Sirtrlrv.„nn
'� SSA Emienmentallkalthl)ivisirn, PIN' 3,4r1)14i1A106
1 Tit ttov HI,25 ln,vt,ns,ni Dow.Ncaton.NC 2lthyt I t r11 2
Snit Address: 6557 PROSPECT DR,CONOVER NC 28013
Marne on Penn*: 'SW ASSOCIATES,INC
Property Sin: Acres 1.1
Direction: Turn onto Vafwood Rd oft of St Petons March Rd I oft ontn Wegewood Or Lot on frft on Provpnrt Dr
Owner/Authorized Representative Acknowledgement of Permit Receipt
X I certify that 1 am the Quart or authorised agent(owner's nuthurirdiun required)representing the owner of
the property dcssrihed above.
Klv As the property owner or authorized representative.I have received the above referenced
permit(s)as requested in the application for service R1111'14-O.l-2022-40611H,by the following methral(s):
_ Received in Person
Facsimile Transmittal(Return form with signature required)
—y
"1 ' Electronic Image Transmittal/E-mail (Return receipt required)
IjL" As the pmperty owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 1 SA.1900),
and/or Well Construction Standards(ISA NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Dale:04/192023
Owner/Authorized Representative Signa ure
Date
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (nwrre of person sending permit)
Signature DateJlime
A51)-3
Method: Fa: Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yoiPlease hake a few momentts tto complette our custtomer servke survey att
http://www.surveymonkey.com/s/EHCusttonierServIce
Itw3/9g6d3ro <<Ld. avo
J' 5 I + 2j
11
1'
1
1 am)norl tJ It
120 CaITtSCanncI-
V, CATAWBA COUNTY Case# AUTH-04-2023-193922
41.1116.0
(.fi. .y Public FleaIth Department Subdivision
.......i.i Environmental Health Division PIN# 374501488306
PO Box 389,25 Government Drive,Newton.NC 28658 LOT# 2
w
Site Address: 6557 PROSPECT DR, CONOVER NC 28613
Name on Permit: *SWASSOCIATES, INC
Property Size: Acres 1.1
Directions: Turn onto Valwood Rd off of St Peters Church Rd. Left onto Wegewood Dr. Lot on left on Prospect Dr.
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? Yes Basement Plumbing? Yes Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LIAR: 0.3 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1,000 gal
Pump Tank 1,000 gal Grease Trap_gal
Dosing Volume 138 gal Pump Specs: 32.7 GPM @ 50.5 TDH
Pressure Head 2 ft Draw Down _ 6.6 in
Drainfield: Total Area: 906 sq ft Total Trench Length: 302 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 32 in
Minimum Soil Cover: 12 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
Do not cut,drive, fill, or grade over septic or repair areas.
*Solid pipe through the old power line trench. Extra pipe and end caps will be needed for this.
*Septic system must be 10 ft from property lines, 10 ft from water lines, 25 ft from basement cuts, 5 ft from
building foundations and appurtenances, and out of right-of-ways and easements.
*Install a 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface), and
a 1,000 gallon pump tank with risers.
*Pump tank will pump to a pressure manifold with 5 taps. lines 1-3 sch 80 1/2"taps, lines 4-5 sch 401/i"taps.
*Install 302 linear feet of 25%reduction system, proposed 5 lines total.
*Laid out lines 2,4, and 5 with inferred lines for lines 1 and 3. 1st line 54 ft(inferred),2nd line 58 ft(green), 3rd
line 58 ft(inferred),4th line 66 ft(orange), and 5th line 66 ft(blue).
*Final grade of septic area must shed surface water off and away from system.
*All gutter drains must be routed away from the septic system.
ehpenuit 05/042023 16:35
gI� CATAWBA COUNTY Case# AUTI I-04-2023-193922
•
H .i. ,. Public Health Department Subdivision
( '� Environmental Health Division PIN# 374501488306
Ili
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 2
I8(...... sw
Site Address: 6557 PROSPECT DR, CONOVER NC 28613
Name on Permit: *SW ASSOCIATES, INC
Property Size: Acres 1.1
Directions: Turn onto Valwood Rd off of St Peters Church Rd. Left onto Wegewood Dr. Lot on left on Prospect Dr.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 g.p.d./ft2
Proposed System: 50%REDUCTION VERTICAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes.or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (I SA NCAC 18A 1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification Please notify Environmental Health of this change prior to system installation.
�`1.5, ---
04/19/2023
Authorized State Agent Permit Issuance Date
4/19/2028
Pemtit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehimnnn 05/04/2023 16:35
IP, 4-C et &OM 04-2022 -Ljo6S8
Catawba County Environmental Health ' '- 04-2O2 113722
1
19.01 243.88 16.71
1127 b� 4347
110.57
38.83
1
a7��r.
✓ R
1\ 24.9 h �' 83 vim. .� �� I„�
�R4 ! 9 A
ir
19.95 4',' nw y s *TYP�►�sL.
. . y,<{., q4
13.31 . •
„'A�.11.' S , , 4"'
• 7� r~rsecl
F
s. (� tdJL e
31.15 << , ti z i,� Kra
2i.56 Sw. $' 3 foam
e Y ,Se IAL
43.80 p�•- r
10.00
iii T ,s
6.85 36r 94• r'�4�
•
1 `.,, �•.k
go'
\ 179 h�
7. \ 213.48
'L�� �o-
4
10
NN.
/3 �� 139.10
CP
CS
Parcel: 374501488306, 6557 PROSPECT DR lin=60ft
CONOVER, 28613
This mepheport product was prepared from the Catawba Ca ,NC Geospadal kifomiadon Services. Catawba County has made substardial efforts
to ensure the accuracy of location and labelnq information aorrfained on this map or data on this report Catawba County promotes and recommends
the independent verification of any data contorted on He map/report product by the user.The County of Catawba,ils employees,agents,and
personnel,discisim,and shell not be held gable for a/and al damages,loss or liabiity,whether direct,lndrect or consequential which arises or may
arise from this mapheport product or the use thereof by any person or entity.
Copyright 2023 Catawba County NC
04/19/2023
toc
6
SYSTEM
lilts# gsla E kcaliffi Lett! )io.$iaa Brisase 9124 Trench Ana BAR
1 54 SCH 80 12 5.48 64.34 162 0.40
2 55 SCH 80 12 5.48 64.34 174 0.37
3 Bs SCH 80 12 6.48 64.34 174 0.37
4 64 SCH 4012 7.11 83.48 198 0.42
5 66 SCH 40 1/2 7.11 83.48 198 0.42
total tread : 302 paWmin_ 30.66
Dos.Flow 360
Punp RIME 11.74
soil LTAR 0.3
(EZLAY lbw+6%) 0.315
LIAR with INNOV.+6% 0.4
LIAR with NOV.W 0.42
'foL 'g 20
CALCULATIONS
Location
Project Number
Lot No:
No. of Bedrooms 3
Design Flow 360°"/Q,,,
LTAR 0.3°"/n2cry
EZ-Lay?(YES OR NO) YES
Supply Line Length 250 ft.
Supply Line Volume 43.5 gal. FRICTION FACTOR
INTERPOLATER
Required Feet of Line 300 ft. 2"SCH 40 PVC
Amount of Line from Layout 302 ft. GPM f
20 0.84
Gallons per Minute 30.66°"/,,,,,, plus 2 --3 32( -0.88
25 1.27
Required Septic Tank Capacity 1000 gal. -1.28
Minimum Standard Tank Size 1000 30 1.78
-1.76
Lateral Line Volume 197.206 gal. 35 2.37
-2.25
Dosing Volume 138.04 gal. 40 3,03
Note: Dosing volume based on 70% 43.07 3.48
of the lateral line volume. 45 3.77
48.14 4.28
50 4.58
57.11 5.89,
60 8.42
Tank Draw Down 6.6 Generic Draw Down of 21 gal.per in.
Pump Run lime 4.50 minutes
Elevation Head 36 ft
Pressure Head 2 ft.
Friction Factor 2.37 ft./100 ft. (From the interpoiater.)
Friction Head 5.93 ft.
Total Dynamic Head(+15%) 50.51 ft.