HomeMy WebLinkAboutWELL-04-2023-192896.tif CATAWBA COUNTY Case# WELL-04-2023-192896
4N• Public Health Department Subdivision CAROLINA CENTERS LLC
,1 3 Environmental Health Division PIN# 461801193017
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
Site Address: 8178 ISLAND POINT RD, SHERRILLS FORD NC 28673
Name on Permit: CANESIAN THEORY HOLDINGS LLC
Property Size: Acres 64.04
Directions: Sherrills Ford Rd, right Island Point Rd,on left
NEW WELL PERMIT
REQUIRED WELL SETBACKS:
Septic Systems and Repair Areas for Single Family Dwellings 50 ft.
Septic Systems and Repair Areas for Businesses and Multi-Family Residences 100 ft.
Underground Storage Tanks 100 ft.
Animal Barns 100 ft.
Lakes/Ponds 50 ft.
Streams/Brooks/Creeks/Rivers 25 ft.
Building Foundations 25 ft.
All Other Sources of Groundwater Contamination 100 ft.
Saprolite Septic Systems and Repair Areas 100 ft.
Septic Systems and Repair Areas to Wells with 2 or more connections 100 ft.
PERMIT CONDITIONS
See attached conditions.
Wells shall be constructed in accordance with state regulations:
Article 15A North Carolina Administrative Code Subchapter 2C
The well driller must verify all setbacks before drilling the well.If the well driller is unable to maintain any of
the above setbacks,contact Catawba County Environmental Health at 828-465-8270,before drilling the well.
Grouting Depth:20 feet minimum
Casing Height: 12 inches minimum above finished grade
All newly constructed private dnnking water wells are required to be sampled in accordance with the North Carolina Rules Regarding Private
Drinking Water Well Testing(15A NCAC 18A.3800).The fee for this sampling is included in the cost of the well permit.It is the applicant or
property owner's responsibility to notify Environmental Health when the well is ready for sampling.Water samples will be drawn from an
outside faucet unless otherwise specified.For questions or for more information,please contact Environmental Health.
04/03/2023
Authorized State Agent Permit Issuance Date
4/3/2028
Permit Expiration Date
ehpemtit 04/06/2023 09:41
Well Permit Conditions for 8178 Island Point Rd WELL-04-2023-192896
15A NCAC 18A.1722 WELL HEAD PROTECTION
(a)The base plate of a pump placed directly over the well shall be designed to form a watertight seal
with
the well casing or pump foundation.
(b) In an installation where the pump is not located directly over the well,the annular space between
the
casing and pump intake or discharge piping shall be closed with a watertight seal designed specifically
for
this purpose.
(c)The well shall be vented at the well head to allow for pressure changes within the well except when a
suction lift type pump is used.Any vent pipe or tube shall be screened or otherwise designed to prevent
the
entrance of insects or other foreign materials.
(d) For a well constructed after July 1, 1993, a hose bib shall be installed at the well head for obtaining
samples. In the case of offset jet pump installations, the hose bib shall be installed directed downward
on
the pressure side of the jet pump piping. A vacuum breaker or backflow prevention device shall be
installed on the hose bib.
(e) For a well constructed after July 1, 1993, a continuous bond concrete slab or well house concrete
floor
extending at least three feet horizontally around the outside of the well casing shall be provided. The
minimum thickness for the concrete slab or floor shall be four inches. The slab or floor shall slope to
drain
away from the well casing.
(f) Any establishments permitted or licensed after July 1, 1993 shall have a continuous bond concrete
slab
or well house concrete floor extending at least three feet horizontally around the outside of the well
casing.
The minimum thickness for the concrete slab or floor shall be four inches.The slab or floor shall slope to
drain away from the well casing.
History Note: Authority G.S. 95-225; 130A-5(3); 130A-230; 130A-235; 130A-236; 130A-248;
#.A CO Case# WELL-04-2023-192896
7 CATAWBA COUNTY HEALTH DEPARTMENT
Environmental Health Section
1$4 2 sM 07/20/2023
WATER SAMPLE FIELD REPORT
.\pplicant ( -\Ni'.SIAN I I IiORY HOLDINGS LLC,2548 I'I:RRYVIEW LN,DF.NVI{IZ NC 28037
C:7049893I38 CCANE36@GMAIL.COM
Site Address: 8178 Island Point RI), Sherrills Ford NC 28673
Name of Subdivision: CAROLINA CENTERS LLC
Parcel Number: 461801193017
Driving Directions Sherrills Ford Rd,right Island Point Rd,on left / n
Sample Collected by: �W l5 '��'1 Date/Time Sampled: °?/ 2-L/I2-9 /o ' /s / t ih
Sampling Point: S�►,n l.t- a I
Is well head accessible? Yes ✓ No Reason for inaccessibility _
Well New or Existing? New V Existing
Type of Well: Drilled ✓ Bored Hand Dug Punch
Does well meet adequate construction standards from what can be observed: ✓Yes No
Items of non-compliance: Evidence of improper grouting or no grouting
Well does not meet a required setback(comment)
Improperly constructed sanitary well seal
Well head not term at>= 12"above finished grade
Well head missing vent
Well head does not have a threadless tap
Well missing identification plate or pump tag
Wire conduit opening not scaled
Other(comment)
Comment:
rsamfieldreport 07/20/2023 13:26 Page 1 of 2
#A Case# WELL-04-2023-192896
FT t 111— C'4 CATAWBA COUNTY HEALTH DEPARTMENT
Environmental Health Section
18 4 2 s i 07/20/2023
WATER SAMPLE TEST RESULTS
Applicant CANESIAN'1llliO10' IIUI.I)INGS LLC,2548 PERRYVIEW I,N,DENVER NC 28037
C:7049893138 CCANE36@GMAIL.COM
Site Address: 8178 Island Point RD,Shen-ills Ford NC 28673
Name of Subdivision: CAROLINA CENTERS LLC
Parcel Number: 461801 193017
Lab Coliform Analysis Results: Total Coliforms: v 1tA 't Fecal/E.Coli: C'� ,�,'I I}-
No Collection Date Over 30 hours old
Invalid Results: Excessive turbidity Excessive Chlorine
Lab Accident
Lab Tech Initials Date/Time Received 011411(1). \" OV Date/Time Completed 03*ir13)(1) I O
L iVLSD
Jl1l. 2 23
Environmental Health
rsamlieldreport 07/20/2023 13:26 Page 2 of 2