HomeMy WebLinkAboutAUTH-04-2023-193016.TIF I�• CATAWBA COUNTY Case# AtJ TH-04-202 3-193016
.1.IR.. Public Health Departmentlig
Subdivision
'II Environmental Health Division PIN# 372312876069
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 1,2,4
w
Site Address: 4447 SECTION HOUSE RD, HICKORY NC 28601
Name on Permit: CATAWBA COUNTY
Property Size: Acres 2.09
Directions: Corner of Section House Rd and Hunters Chase Dr
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 450 g.p.d.
Type of Facility: Business-EMS base-system for base; domestic wastewater
Basement? No Basement Plumbing? Bedrooms:
Water Supply: Public Water Maximum Occupants:
Soil LTAR: 0.3 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 1,206sq ft Total Trench Length: 402 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 12 in Minimum Trench Separation: g ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: Distribution Box
Pre Treatment: NONE
Additional Specifications:
Maximum of 18 employees-6 employees per eight hour shift, three shifts per day. No bedrooms or sleeping
quarters.
See state approved design.
Adjust locations of proposed trees so that no tree is planted over septic tank, distribution box, or drainfield
header ditch. It is recommended that large trees are not over drainfield.
Temporary sediment basin located beside drainfield (in the southwest corner of the property)must be filled in
prior to building final and/or issuance of building CO.
All septic system components must be at least 50ft from any well, 10 ft from water lines, 5ft from structures,loft
from property lines, 15ft from ditches, and out of any right-of-way or easement. Surface water from parking lot
must not shed onto drainfield.
Do not drive,grade, cut, or fill over system area or septic repair area.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 g,p.d.lft2
eI q,r❑n u 04/06/2023 I I:05
,113' CATAWBA COUNTY Case# AUTH-04-2023-193016
44(.....,t` ,� Public Health Department Subdivision
d O 1 Environmental Health Division PIN# 372312876069
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 1,2,4
/g.2 sM
Site Address: 4447 SECTION HOUSE RD, HICKORY NC 28601
Name on Permit: CATAWBA COUNTY
Property Size: Acres 2.09
Directions: Corner of Section House Rd and Hunters Chase Dr
Proposed System: 25%REDUCTION
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Pump Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Ileahnent and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
Kol::_t, -0:1
04/04/2023
Authorized State Agent Permit Issuance Date
4/4/2028
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehpeimil 04/04/2023 16:34
,- ;tS ATEq, ,,•vo, ROY COOPER• Governor
: ,n„' 40 .;...S' NC DEPARTMENT OF KODY H. KINSLEY• Secretary
1 ill a` i HEALTH AND"�� � HUMAN SERVICES MARK BENTON • Deputy Secretary for Health
f j��,z• SUSAN KANSAGRA•Assistant Secretary for Public Health
Division of Public Health
March 8, 2023
Ms. Megen McBride
Catawba County Health Department
25 Government Dr
Newton, NC 28658
Subject: Approval of St Stephens EMS Base Wastewater System Plans and Specifications
4447 Section House Rd, Hickory, Catawba County, NC
Project Number 2022-31
Dear Ms. McBride:
We have reviewed revised plans and specifications for the wastewater system proposed to serve the St
Stephens EMS Base, 4447 Section House Rd, Hickory, Catawba County, received from Miles Wright, PE,
Wright &Associates.
The approved plans and specifications are for the following facilities and system components:
Facilities: EMS Base with a total of 18 employees(six employees per eight hour shift,three shifts per day)
and a floor drain in the garage bay
System:
Garage bay system—OS-100 oil/water separator from Striem; 1-1,000 gallon septic tank; and one gravel
dispersal field (335 linear feet total in one field)
Base system—1-1,000 gallon septic tank; and one dispersal field (402 linear feet in one field)
Design Flow: Garage bay system—300 gallons/day; Base system—450 gallons/day
Drainfield Loading Rate: 0.30 gpd/sq ft
Treatment Standard: Septic tank effluent
System classification:V, requiring twice a year ORC inspections with annual inspection reports submitted
to the local health department and at least yearly inspection by your department
NC DEPARTMENT OF HEALTH AND HUMAN SERVICES•DIVISION OF PUBLIC HEALTH
LOCATION:5605 SIX FORKS RD, RALEIGH NC 27609
MAILING ADDRESS: 1642 MAIL SERVICE CENTER,RALEIGH NC 27699-1642
www.ncdhhs.gov•TEL:919-707-5874•FAX:919-845-3972
AN EQUAL OPPORTUNITY/AFFIRMATIVE ACTION EMPLOYER
St Stephens EMS Base March 8, 2023
A certified subsurface operator shall be contracted to operate the system.
The operation permit must include, as conditions, the O&M procedures attached to the approved
specifications. It shall also include the necessary information regarding the proposed management entity
and certified operator as well as any additional concerns deemed appropriate by the health department
for the O&M of this system.
The installation must be approved by the health department and engineer prior to the issuance of an
operation permit.
Please contact us if you have any questions pertaining to this letter or if we may be of further assistance
with this project. I can be contacted at 919-707-5878, 919-218-2580,or trish.angoli@dhhs.nc.gov.
Sincerely,
Tricia ngo i, PE
On-Site Wastewater Engineering
Enclosures
cc: Miles Wright, PE, Wright&Associates
2
St. Stephens EMS Base
Septic System
Design Criteria
Catawba County
2/2/2023
Flow Calculation
EMS Base with On Site Staff 25 Gallons/Employee/Shift 15A NCAC 02T.0114 WASTEWATER DESIGN FLOW RATES
Staff per Shift 6
#of Shifts 3
Total Flow= 450 gpd
Flow = 450.00 gpd
LTAR = 0.3 gpd/sf
Area of trench = 1500 sf
Length of line = 500 ft
25%Reduction = 375 LF
No of fields = 1
Lineal ft per field = 375
No.of lines = 5
lineal ft per line = 75
Use = 60
Septic Tank Sizing
Volume = V=20
Q = 450.00 gallons per day
Volume = 900.00 gallon
Use 1 i 1000igalion
Septic tank shall bear the NCDEQ approval stamp
Approved By
ON-SITE WASTEWATER
Department of Health & Human Services
File No: -,31
Dim: Si 0062z
BY: