Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AUTH-04-2023-192952.TIF
yyA• CATAWBA('OUNTI Case# Atll'1-1-04-2023-192952 1~ t li ,y Public Health Department Subdivision j Environmental Health Division PIN# 460701095413 PO Box 389.25 Government Drive.Newton,NC 28658 LOT# 4 8.2 sm Site Address: 6857 LOCKE DR, SHERRILLS FORD NC 28673 Name on Permit: DANIEL LYNCH Property Size: Acres 1.35 Directions: NC 16 Left Rent Drum RD, Right Little Mtn RD, Left Mt Pleaseaaant Rd, Left Locke Dr Property on Left Authorization to Construct Permit Permit Category: New Septic Wastewater Flow: 360 g.p.d. Type of Facility: Primary Residence-New house Basement? Yes Basement Plumbing? No Bedrooms: 3 Water Supply: Private Well Maximum Occupants: 6 Soil LTAR: 0.2 g.p.d./ft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 50%REDUCTION HORIZONTAL System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP Septic Tank: New Tank: 1,000 gal Pump Tank 1.000 gal Grease Trap gal Dosing Volume _ 250 gal Pump Specs: 39.41 GPM© t8 TDH Pressure Head 2 ft Draw Down 11.9 in Drainfield: Total Area: sq ft Total Trench Length: 300 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 20 in Minimum Soil Cover: 6 in Minimum Trench Separation: 8 ft on center Number of Drain Lines: 5 Trench Width: 3 ft Distribution: Pressure Manifold Pre Treatment: NONE Pump Required Additional Specifications: *Install 69 T&J panel blocks total. *6.68 minute pump run. *Tap sizes found on the pressure manifold spec sheet. *Serial feed the 32'line with a drop box placed at the 50'line. *One SCH 40 1/2"tap will feed the drop box at the 50'line. *Use 5/32 inch holes in the distribution pipe drilled at the 10 and 2 o'clock positions. Drill one hole per block. *Install the 1x6 boards under the blocks *Rake and lime the side walls *Seal both the outer and inner compartments of the T&J panel with foam. The outer seal is a complete seal and the inner seal is only up to the top of the connecting pipe. *Use approved backfill sand. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and may result in failure to approve the initial system installation• or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Required Soil LTAR: 0.1 g.p.d.lft2 1,1,,i n,n 04 13'2023 11.26