Loading...
HomeMy WebLinkAboutAUTH-03-2023-191899.TIF �gA a ('ATANBA cot'NT1 Case# n11111-03-2023-191899 Public Health Department tiuhdisision SHANNONBROOK DEV dLe.)AI "j l:nvironmental Health Division PIN# 373010257435 j 'C PO Box 389,25( overnment Drive.Newton,NC 28658 LOT# 9 I8 2 w Site Address: 1230 SHANNONBROOK DR, NEWTON NC 28658 Name on Permit: DENNIS GORDON Property Size: Acres 0.47 Directions: Radio Station RD. Right inti Shannonbrook DR property on left Authorization to Construct Permit Permit Category: Expansion Wastewater Flow: 480 g.p.d. Type of Facility: Primary Residence- Basement? Yes Basement Plumbing? Yes Bedrooms: 4 Water Supply: Public Water Maximum Occupants: 8 Soil LTAR: 0.3 g.p.d.lft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 50% REDUCTION VERTICAL System Classification: IIIE-PPBPS GRAVITY DOSED SYSTEM Septic Tank: Existing Tank 1.000 gal Pump Tank _gal Grease Trap_gal Dosing Volume gal Pump Specs: GPM @ TDH Pressure Head ft Draw Down in Drainfield: Total Area: 201 sq ft Total Trench Length: 67 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 35 in Minimum Soil Cover: 6 in Minimum Trench Separation: ft on center Number of Drain Lines: 1 Trench Width: 2 ft Distribution: Distribution Box Pre Treatment: NONE Additional Specifications: *Permit for expansion of septic system for one additional bedroom. *Existing septic tank will be used unless it does not meet current rules, if not a new 1000 gal septic tank will be required. *If existing septic tank can not be used, it must be properly abandoned(pumped, crushed and filled). *Install new distribution box with four outlets, three outlets will go to existing bed and one will go to new line. Feed all outlets equal with speed levelers. *Install 67 linear feet of vertical T&J below existing septic bed area maintaining at least 6 feet between trench and bed side walls. *New line must remain a minimum of 5 feet from property line and any building structure. *New line will contain 15 panels. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Required Soil LTAR: 0.3 9•P•d.lft2 Proposed System: 50%REDUCTION VERTICAL System Classification: IIIE-SYSTEM W/SINGLE EFFLUENT PUMP 03282(72; nv;I A• CATAWBA COUNTY Case# AUTH-03-2023-191899 r-� Public Health Department Subdivision SHANNONBROOK DEV „ { Environmental Health Division PIN# 373010257435 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 9 �I• . a Site Address: 1230 SHANNONBROOK DR, NEWTON NC 28658 Name on Permit: DENNIS GORDON Property Size: Acres 0.47 Directions: Radio Station RD, Right inti Shannonbrook DR property on left Pump Required The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. °I )ledf&%t. 1/1°W1(1 03/21/2023 Authorized State Agent Permit Issuance Date 3/21/2028 Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department ehpennit 03/22/2023 09:27 Catawba County Environmental Health 24PR-o 1- Zo23 - Li375 I1P,4_03 _zc2? - 1R189b Ate . 03_ Zo�3 -►51855 •1226 �o cQ • -I, le� 1 Cr' !o `( \a Prat q �1 52.54 4-9 bo+ Exs� .-.. is' 36a•123. 'c '1l 1 00.0 0 F 23.46 �O 2ssSO •1234 100.s' 00.00 •1231 Parcel: 373010257435, 1230 SHANNONBROOK tin=50ft DR NEWTON, 28658 This map/report product was prepared from the Catawba County,NC Geos allal Information Services. Catawba County has made substantial efforts to ensure the accuracy of location end labeling information contained on this mop or date on this report.Catawba County promotes and recommends the independent verification of any data contained on this map/report product by the user.The County of Catawba,its employees,agents,and personnel,disclaim,and shalt not be held liable for any and all damages,loss or liability,whether direct,Indirect or consequential which arises or may arise from this map/report product or the use thereof by any person or entity. Copyright 2023 Catawba County NC 02/282023