HomeMy WebLinkAboutAUTH-03-2023-191726.TIF CATAWBA COUNTY Case it
Health Department Subdivision
Environmental Health DivisionI'IN� Al1Tll 03 2023 19(...... ) 172G
460718325355
ikknoi .
PO liox 389,25 Government!)rive.Newton,NC 28658 I.C)TS
Site Address: 7409 NORMAN DR, SHERRILLS FORD NC 28673
Name on Permit: TAMARA BENTON
Property Size: Acres 0.61
Directions: Hwy 150,turn left on Little Mtn Rd,travel about 1 mile, right on Norman Drive,go past curve house on the right
Owner/Authorized Representative Acknowledgement of Permit Receipt
Nk _tab] certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
the property described above.
"I(i' tSb As the property owner or authorized representative. I have received the above referenced
permit(s)as requested in the application for service EHI'R-12-2021-39513,by the following method(s):
Received in Person
Facsimile Transmittal (Return form with signature required)
_d' Electronic Image'l'ransmittal/E-mail (Return receipt required)
•�( tSbAs the property owner or authorized representative I have reviewed and understand the specific conditions
1` of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems (15A NCAC 18A.1900),
and/or Well Construction Standards (15A NCAC 2C .0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date:03/20/2023
Owner/Authorized Representative Signature Tamara Benton
Date 3 29 23
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of person.sending permit)
Signature ^ Date/Time. 1311)3
Method: Fax /Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from youPlease ttake a few momentts tto complette our custtomer service survey att
http://www.surveymonkey.com/s/EHCusttomerService
cti I /() 1 ('ya heo. (c r
l!aj 0 (y1a;,i,,u)rt.tc;t�. (4,4,
.•�i, � 03/29l2023 15.14
.4.1y, . CATAWBA COUNTY Case# AUl I1-03-2023-191726
I" G� Public Health Department
d „�O Environmental Health Division PIN# 460718325355
ki Subdivision
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
\842 ,.
Site Address: 7409 NORMAN DR, SHERRILLS FORD NC 28673
Name on Permit: TAMARA BENTON
Property Size: Acres 0.61
Directions: Hwy 150,turn left on Little Mtn Rd,travel about 1 mile, right on Norman Drive, go past curve house on the right
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Community Well Maximum Occupants: 6
Soil LTAR: .35 g.p.d.1ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50%REDUCTION HORIZONTAL
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1.000 gal
Pump Tank 1.000 gal Grease Trap_gal
Dosing Volume 144 gal Pump Specs: 23.92 GPM @ 21.51 TDH
Pressure Head 2 ft Draw Down 7.2 in
Drainfield: Total Area: 513 sq ft Total Trench Length: 171 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 20 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 5 ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
Keep all parts of repair system minimum: 100'from shared well above driveway, 50'from individual well on
neighboring lot at Norman Dr, 50'from lake 760 contour, 5'from garage, 5'from property lines.
Lines to be installed on contour and have been shot in by EHS.
Pink 44'near large tree at lowest point 10 panels
White 42' 10 panels
Blue 38' 9 panels
White 32'7 panels
Unmarked 16' line at setback for neighbors well 4 panels
Use a schedule 80 pressure manifold with (4) 1/2"schedule 80 taps. Feed the 32'and 16' line from 1 tap and
feed tap into drop box to serial feed these 2 lines.The other 3 lines to be fed from from separate taps. Use a 2"
pump supply line.
Existing tank under the home in crawl space will need to be abandoned. Tank is to be pumped out and concrete
may be pumped into the tank until filled.
Met with installer Dewey Grant on 3/2/23 for preconstruction conference.
L p n ut 03/2912023 15:t 4
�t��t3' ,. CATAWBA COUNTY Case# AUT1l-03-2023-]91726
G Public Health Department Subdivision
a
(.......
n 0 , Environmental Health Division PIN# 460718325355
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
Site Address: 7409 NORMAN DR, SHERRILLS FORD NC 28673
Name on Permit: TAMARA BENTON
Property Size: Acres 0.61
Directions: Hwy 150,turn left on Little Mtn Rd,travel about 1 mile, right on Norman Drive, go past curve house on the right
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Soil LIAR: g.p.d.lft2
Proposed System:
System Classification:
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Pennit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
03/20/2023
Authorized State Agent Permit Issuance Date
3/28/2023
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
I.p.rnat 03/29/2023 15:14
Department of Environment,Health,and Natural Resources Sheet:
Division of Environmental Health Property ID:
On-site Wastewater Section Lot#:
SOIUSITE EVALUATION File#:
for ON-SITE WASTEWATER SYSTEM AppID: EHPR-12-21-39513
Owner: Tamara Benton Applicant:
Address: 7409 Norman Dr Date Evaluated: 11/9/2022
Proposed Facility: 3 BR Home Design Flow(.1949) 360 Property Size:
Location of Site: Property Recorded:
Water Supply: shared well [ ]Spring [ ]Other
Evaluation Method: pits by Dewey Grant [ ]Cut
Type of Wastewater: X Sewage [ ]Industrial Process [ ]Mixed
P
R
O SOIL MORPHOLOGY b
F .1941 PROFILE FACTORS
I .1940 .1942
L Landscape Horizon .1941 .1941 Soil .1943 .1956 .1944 Profile
E Position! Depth Structure! Consistence Wetness/ Soil Sapro Restr Class
# Slope% (IN.) Texture Mineralogy Color Depth(IN.) Class Horiz <AR
1 LL 9-10% 0-4"A SUGR NS NP NEXP VFR
4-8"B SCU w SBK SS SP SEXP FR
8-19"B C/SBK SS SP SEXP FR 37" PS.35
19-37"BC SCL+Sap SS SP SEXP FR
37-48" SL Sap NS NP NEXP VFR
2 LL 9-10% 0-4"A SU GR NS NP NEXP VFR 37" PS.35
4-7"B SCU w SBK SS SP SEXP FR
7-24"B C/SBK SS SP SEXP FR
24-37"BC SCL+Sap SS SP SEXP FR
37-48" SL Sap NS NP NEXP VFR
Description Initial System Repair System Other Factors(.1946):
Available Space(.1945) PS Soil Evaluation By: Robert Phelps Jason Boyd
System Type(s) Existing IIIB 50%red Others Present: Dewy Grant's FIL Billy
Site LTAR .35 Site Classification(.1948): PS
Site Evaluation By:
Others Present: