Loading...
HomeMy WebLinkAboutAUTH-03-2023-191726.TIF CATAWBA COUNTY Case it Health Department Subdivision Environmental Health DivisionI'IN� Al1Tll 03 2023 19(...... ) 172G 460718325355 ikknoi . PO liox 389,25 Government!)rive.Newton,NC 28658 I.C)TS Site Address: 7409 NORMAN DR, SHERRILLS FORD NC 28673 Name on Permit: TAMARA BENTON Property Size: Acres 0.61 Directions: Hwy 150,turn left on Little Mtn Rd,travel about 1 mile, right on Norman Drive,go past curve house on the right Owner/Authorized Representative Acknowledgement of Permit Receipt Nk _tab] certify that I am the owner or authorized agent(owner's authorization required)representing the owner of the property described above. "I(i' tSb As the property owner or authorized representative. I have received the above referenced permit(s)as requested in the application for service EHI'R-12-2021-39513,by the following method(s): Received in Person Facsimile Transmittal (Return form with signature required) _d' Electronic Image'l'ransmittal/E-mail (Return receipt required) •�( tSbAs the property owner or authorized representative I have reviewed and understand the specific conditions 1` of the permit issued, and further understand that all applicable regulatory requirements specified under the North Carolina Laws and Rules for Sewage Treatment and Disposal Systems (15A NCAC 18A.1900), and/or Well Construction Standards (15A NCAC 2C .0100), shall apply to the issuance of this permit and the construction of the wastewater system and/or water supply well permitted. Permit Issue Date:03/20/2023 Owner/Authorized Representative Signature Tamara Benton Date 3 29 23 Documentation of Permit(s)Transmittal (permit transmitted by electronic or other means) Permit transmitted by (name of person.sending permit) Signature ^ Date/Time. 1311)3 Method: Fax /Email US Mail Other Owner's request to send by the above indicated method of transmittal in lieu of signature We wantt tto hear from youPlease ttake a few momentts tto complette our custtomer service survey att http://www.surveymonkey.com/s/EHCusttomerService cti I /() 1 ('ya heo. (c r l!aj 0 (y1a;,i,,u)rt.tc;t�. (4,4, .•�i, � 03/29l2023 15.14 .4.1y, . CATAWBA COUNTY Case# AUl I1-03-2023-191726 I" G� Public Health Department d „�O Environmental Health Division PIN# 460718325355 ki Subdivision PO Box 389,25 Government Drive,Newton,NC 28658 LOT# \842 ,. Site Address: 7409 NORMAN DR, SHERRILLS FORD NC 28673 Name on Permit: TAMARA BENTON Property Size: Acres 0.61 Directions: Hwy 150,turn left on Little Mtn Rd,travel about 1 mile, right on Norman Drive, go past curve house on the right Authorization to Construct Permit Permit Category: Repairs Wastewater Flow: 360 g.p.d. Type of Facility: Primary Residence- Basement? No Basement Plumbing? No Bedrooms: 3 Water Supply: Community Well Maximum Occupants: 6 Soil LTAR: .35 g.p.d.1ft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 50%REDUCTION HORIZONTAL System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP Septic Tank: New Tank: 1.000 gal Pump Tank 1.000 gal Grease Trap_gal Dosing Volume 144 gal Pump Specs: 23.92 GPM @ 21.51 TDH Pressure Head 2 ft Draw Down 7.2 in Drainfield: Total Area: 513 sq ft Total Trench Length: 171 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 20 in Minimum Soil Cover: 6 in Minimum Trench Separation: 5 ft on center Number of Drain Lines: 5 Trench Width: 3 ft Distribution: Pressure Manifold Pre Treatment: NONE Pump Required Additional Specifications: Keep all parts of repair system minimum: 100'from shared well above driveway, 50'from individual well on neighboring lot at Norman Dr, 50'from lake 760 contour, 5'from garage, 5'from property lines. Lines to be installed on contour and have been shot in by EHS. Pink 44'near large tree at lowest point 10 panels White 42' 10 panels Blue 38' 9 panels White 32'7 panels Unmarked 16' line at setback for neighbors well 4 panels Use a schedule 80 pressure manifold with (4) 1/2"schedule 80 taps. Feed the 32'and 16' line from 1 tap and feed tap into drop box to serial feed these 2 lines.The other 3 lines to be fed from from separate taps. Use a 2" pump supply line. Existing tank under the home in crawl space will need to be abandoned. Tank is to be pumped out and concrete may be pumped into the tank until filled. Met with installer Dewey Grant on 3/2/23 for preconstruction conference. L p n ut 03/2912023 15:t 4 �t��t3' ,. CATAWBA COUNTY Case# AUT1l-03-2023-]91726 G Public Health Department Subdivision a (....... n 0 , Environmental Health Division PIN# 460718325355 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# Site Address: 7409 NORMAN DR, SHERRILLS FORD NC 28673 Name on Permit: TAMARA BENTON Property Size: Acres 0.61 Directions: Hwy 150,turn left on Little Mtn Rd,travel about 1 mile, right on Norman Drive, go past curve house on the right See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Soil LIAR: g.p.d.lft2 Proposed System: System Classification: The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to Construct Pennit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. 03/20/2023 Authorized State Agent Permit Issuance Date 3/28/2023 Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department. I.p.rnat 03/29/2023 15:14 Department of Environment,Health,and Natural Resources Sheet: Division of Environmental Health Property ID: On-site Wastewater Section Lot#: SOIUSITE EVALUATION File#: for ON-SITE WASTEWATER SYSTEM AppID: EHPR-12-21-39513 Owner: Tamara Benton Applicant: Address: 7409 Norman Dr Date Evaluated: 11/9/2022 Proposed Facility: 3 BR Home Design Flow(.1949) 360 Property Size: Location of Site: Property Recorded: Water Supply: shared well [ ]Spring [ ]Other Evaluation Method: pits by Dewey Grant [ ]Cut Type of Wastewater: X Sewage [ ]Industrial Process [ ]Mixed P R O SOIL MORPHOLOGY b F .1941 PROFILE FACTORS I .1940 .1942 L Landscape Horizon .1941 .1941 Soil .1943 .1956 .1944 Profile E Position! Depth Structure! Consistence Wetness/ Soil Sapro Restr Class # Slope% (IN.) Texture Mineralogy Color Depth(IN.) Class Horiz &LTAR 1 LL 9-10% 0-4"A SUGR NS NP NEXP VFR 4-8"B SCU w SBK SS SP SEXP FR 8-19"B C/SBK SS SP SEXP FR 37" PS.35 19-37"BC SCL+Sap SS SP SEXP FR 37-48" SL Sap NS NP NEXP VFR 2 LL 9-10% 0-4"A SU GR NS NP NEXP VFR 37" PS.35 4-7"B SCU w SBK SS SP SEXP FR 7-24"B C/SBK SS SP SEXP FR 24-37"BC SCL+Sap SS SP SEXP FR 37-48" SL Sap NS NP NEXP VFR Description Initial System Repair System Other Factors(.1946): Available Space(.1945) PS Soil Evaluation By: Robert Phelps Jason Boyd System Type(s) Existing IIIB 50%red Others Present: Dewy Grant's FIL Billy Site LTAR .35 Site Classification(.1948): PS Site Evaluation By: Others Present: