HomeMy WebLinkAboutAUTH-03-2023-191483.TIF �►2,: (ATAWBA(OU \'tl Case it �l'fH-0+-2023-l9l483
.�. 2 Public health Department Subdivision CRESCENT LAND AND TIMBE
„��� Environmental Health Division PIN# 460701353748
PO Ito.x 3f9.25 Government Drive.NelAum.NC 28658 LOI# 38
1g42
Site Address: 3799 BURTON ST, SHERRILLS FORD NC 28673
Name on Permit: MARCUS AND KIMBERLY PROPST
Property Size: Acres 0.74
Directions: NC 16, left onto Rant Durm Rd, right onto Little Mountain Rd, left onto Mt Pleasant Rd, right onto Dock Side
Ln, right onto Burton St, home is on the left
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 240 g.p.d.
Type of Facility: Primary Residence-
Basement? Yes Basement Plumbing? No Bedrooms: 2
Water Supply: Private Well Maximum Occupants: 4
Soil LTAR: 0.3 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50%REDUCTION HORIZONTAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Septic Tank: New Tank: 1,000 gal
Pump Tank 1,000 gal Grease Trap_gal
Dosing Volume 165 gal Pump Specs: 23.8 GPM @ 27.7 TDH
Pressure Head 2.5 ft Draw Down 7.0 in
Drainfield: Total Area: 417 sq ft Total Trench Length: 139 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 18 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 8 ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: LPP
Pre Treatment: NONE
Pump Required ***** Operator Required
Additional Specifications:
**SEE NEXT PAGE**
0;2 2023 II III
�y$ ('A fAWBA COI'WI. ('ase# At 1'1'11-03-2023-19148 3
,-(b... 1, Public Health Department Subdivision CRESCENT LAND AND TIMBE
Q (*) • Environmental health Division PIN# 460701353748
� PO 13ox 389,25 Government I)rive.Newton_NC 28658 l.OT# 38
Site Address: 3799 BURTON ST, SHERRILLS FORD NC 28673
Name on Permit: MARCUS AND KIMBERLY PROPST
Property Size: Acres 0.74
Directions: NC 16, left onto Rant Durm Rd, right onto Little Mountain Rd. left onto Mt Pleasant Rd, right onto Dock Side
Ln, right onto Burton St, home is on the left
*Before an operation permit can be issued a signed maintenance agreement will have to be submitted to
Catawba County Environmental Health between the owner and the ORC (operator in responsible charge).
*Do not cut,drive, fill, or grade over septic or repair areas.
*Septic system must be 10 ft from property lines, 15 ft from basement cuts (side slope), 25 ft from basement
cuts(upslope), 50 ft from wells, 5 ft from building foundations and appurtenances, and out of right-of-ways and
easements.
*Install 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface)and a
1,000 gallon pump tank with risers. Floats must be attached to a float tree.
*Existing septic tank must be pumped out, crushed in place, and backfilled with soil.
*Pump tank will pump to a LPP valve box with 5 gate valves that will feed 5 septic lines.
*Supply line will have to be sleeved under the driveway with DOT culvert pipe or be placed at least 30 inches
below the driveway.
*Install 139 linear feet of 50%reduction system(horizontal), proposed 5 lines total on contour.
*Bring in at least 4 inches of clean fill for cover.
*All lines laid out in the field and are longer than proposed
*1st line(flagged orange) is 10 ft(2 panels),2nd line(flagged white) is 37 ft(9 panels), 3rd line(flagged red)is
34 ft(8 panels), 4th line(flagged green) is 34 ft(8 panels), and 5th line(flagged orange) is 24 ft(6 panels). Total
number of PPBPS panels is 33.
*This design utilizes 3/16 holes in the LPP lines with 2.5 ft of pressure head.
*Rake and lime the trench side walls.
*Seal both the outer and inner compartments of the PPBPS with foam. The outer seal is a complete seal and
the inner seal is only up to the connecting pipe.
*Backfill sand must be of ASTM C-33 specifications or approved by T&J Panel.
*Final grade of septic area must shed surface water off and away from system.
*All gutter drains must be routed away from the septic system.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation. or the suspension/revocation of existino permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Not Required Soil LTAR: 9•P•d.lft2
Proposed System:
System Classification:
03'23'2023 1110
- 0 3- -3- 1 l LIB'
David Currier Date of Inspection:
Owner of: LAKE NORMAN 5/22/25
LAKE NORMAN SEWER AND SEPTIC
PO BOX 889 Rk
[]Initial ❑6 Months
Denver, NC 28037
(704)-483-5125
Field location:
License Number:995940
ZOnsite ❑ Offsite
Subsurface Wastewater Inspection Form Offsite septic lot#:
Name & Address of Owner: 'ontrolpanel:
Kim Propst
Conduit sealed: DYES ❑ NO
3799 Burton Street
❑Polystyrene
Sherrills Ford, NC 28037 Alarm operating: DYES ❑ NO ❑Chamber
Panel location: ❑Panel ELPPBS
SEPTIC TANK:
❑Wall 0 Post 18"inches High
OGravel ❑LPP
Size of Septic Tank: 1000 Gallons
Counter- Cycle: N/A Hour: N/A ❑Large diameter pipe
Risers Readily Accessible: ®YES 0 NO ❑Other:
Signs of Infiltration: DYES E NO SEDUCTION TYPE:
Structurally Sound: DYES ❑ NO EType IV(50%reduction)
Size of Pump Tank: 1000 Gallons
Filter(s) Cleaned: EYES ❑ NO ❑Type III (25%reduction)
Pump Model:
Surface Water Diverted: EYES 0 NO 0 None
Pump HP:
Scum Level:0" Pump Voltage: 115v
-lead Settings:
Sludge Level: 13"
Pipework in good condition: [EYES ❑NO
Scum plus Sludge level: 13" E2' ❑ 3' ❑other:
Liquid Depth:40" Control floats operating: EYES ❑ NO
Distribution Set @ inspection:
TANK NEEDS PUMPING: DYES E NO Effluent free&clear of solids: EYES ❑ NO DYES ❑NO
TANK NEEDS PUMPING: OYES Z NO Drain field:
Effluent surfacing:OYES [E NO
Notes and/or Corrective Action Needed: Traffic Protected:[EYES ❑NO
We performed your 15t Type IV inspection for Repair Area Reserved:
the year.At the time of the inspection the DISTRIBUTION TYPE: DYES ❑NO
Surface Water Diverted:
system was functioning. We removed and
EManifold ❑Individual valves [EYES ❑NO
cleaned the outlet filter. We purged out the Line Cover Maintained:
drain field lines and reset the head pressures. OSerial/drop boxes ❑Distribution box ®YES ❑NO
We recommend having the tank pumping in 1 LOW PRESSURE SYSTEM:
year. Pump draw down:
Turn-ups and/or Valves Located/ Gallons per cycle:
Protected:®YES ❑NO
Draw down length:
/�„''�",� / / „ Laterals Free of Excess solids:®Yes ❑NO Tether length if wide angle
INSPECTOR SIGNATURE:i L �" , C Laterals Flushed:DYES ❑NO
float:
au-kk- 03- /904 _
David Currier Date of Inspection:
Owner of: LAKE NORMAN 11/11/25
LAKE NORMAN SEWER AND SEPTIC
PO BOX 889 ❑Initial ❑x 6 Months
sEwER
Denver, NC 28037
(704)-483-5125
Field location:
License Number:995940SEPTIC'
DOnsite D Offsite
Subsurface Wastewater Inspection Form Offsite septic lot#:
Name & Address of Owner: "ontrol panel:
Kim Propst YPE OF SYSTEM:
Conduit sealed: DYES ❑ NO
3799 Burton Street
❑Polystyrene
Sherrills Ford, NC 28037 Alarm operating: DYES ❑ NO ❑Chamber
Panel location: ❑Panel NLPPBS
SEPTIC TANK:
OWall ❑Post 18"inches High
❑Gravel ❑LPP
Size of Septic Tank: 1000 Gallons
Counter- Cycle: N/A Hour: N/A ❑Large diameter pipe
Risers Readily Accessible: DYES ❑ NO ❑Other:
Signs of Infiltration: DYES N NO ;EDUCTION TYPE:
Structurally Sound: DYES ❑ NO Type IV(50%reduction)
Size of Pump Tank: 1000 Gallons
Filter(s) Cleaned: EYES El NO ❑Type III (25%reduction)
Pump Model:
Surface Water Diverted: DYES ❑ NO ❑ None
Pump HP:
Scum Level:0" Pump Voltage: 115v
Head Setting;
Sludge Level: 8" Pipework in good condition:®YES ❑NO
Scum plus Sludge level: 8" D2' ❑ 3' ❑other:
Liquid Depth:40" Control floats operating: DYES ❑ NO
Distribution Set @ inspection:
TANK NEEDS PUMPING: DYES N NO Effluent free &clear of solids: DYES ❑ NO ®YES ❑NO
TANK NEEDS PUMPING: OYES ® NO Drain field:
Effluent surfacing:OYES ®NO
Notes and/or Corrective Action Needed: Traffic Protected:®YES ❑NO
We performed your 2nd Type lv inspection for Repair Area Reserved:
the year. At the time of the inspection the DISTRIBUTION TYPE: ®YES ❑NO
Surface Water Diverted:
system was functioning as intended. We ®YES ❑NO
Manifold ❑Individual valves
removed and cleaned the outlet filter. We saw Line Cover Maintained:
no other concerns or issues at this time. ❑serial/drop boxes ❑Distribution box ®YES ❑No
LOW PRESSURE SYSTEM: Pump draw down:
Turn-ups and/or Valves Located/ Gallons per cycle:
Protected:®YES ❑NO
Draw down length:
Laterals Free of Excess solids:®YES ❑No Tether length if wide angle
INSPECTOR SIGNATURE: Laterals Flushed:®YES 0 No float: