HomeMy WebLinkAboutAUTH-03-2023-191034.TIF er• CATAWBA COUNTY Case# AUTH-03-2023-191034
Public Health Department Subdivision
t� . Environmental IkealthDivision PIN# 373118427106
t PO Box 389,25 Government Drive.Newton,NC 28658 LOT# 6&6A
Site Address: 2257 OLD CONOVER STARTOWN RD, NEWTON NC 28658
Name on Permit: LAURA TRIBBLE
Property Size: Acres 7.42
Directions: Radio Station Rd,right onto Old Conover Startown Rd,left onto Big Cedar Ln, property on the right
Owner/Authorized Representative Acknowledgement of Permit Receipt
0- , certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
the property described above.
tiliP— As the property owner or authorized representative, I have received the above referenced
permit(s)as requested in the application for service EHPR-01-2023-43228,by the following method(s):
_ Received in Person
/ Facsimile Transmittal(Return form with signature required)
si Electronic Image Transmittal/E-mail (Return receipt required)I.,
s the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(I5A NCAC 18A.1900),
and/or Well Construction Standards(I5A NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date:03/10/2023
Owner/A horize Representative Signature_iiu
__ ._ A
4.1)4/1LA n/ J u►--CA r i
—4:7Date322 L d�
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by ___ __ _ (nameof person sending permit)
C
Signature . ___ Date/Time .A 1)3
Method: Fax Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We want tto hear from youPlease take a few moments tto complete our custtomer service survey at
i
http://www.surveymonkey.com/s/EHCusttomerService
�key.com//s/EHCusntommerService
L�V�. h 1(' t b�G 1i' c� �11c'-�.Carl) I L 1..
n ,
J �5 I
03/20;2023 14.2D
�$• • CATAWBA COUNTY Case# AUTH-03-2023-191034
.t. Public Health Department Subdivision
Environmental Health Division 1'1N14 373118427106
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 6&6A
/842
Site Address: 2257 OLD CONOVER STARTOWN RD, NEWTON NC 28658
Name on Permit: LAURA TRIBBLE
Property Size: Acres 7.42
Directions: Radio Station Rd. right onto Old Conover Startown Rd, left onto Big Cedar Ln, property on the right
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 240 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 2
Water Supply: Private Well Maximum Occupants: 4
Soil LIAR: 0.275 g_p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 654 sq ft Total Trench Length: 218 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not drive,grade, cut or fill over any part of the septic area.
*Existing septic tank MUST be properly abandoned (pumped, crushed and filled).
*Install new 1000 gal septic tank(risers required on tank if more than 6in of cover)and 218 feet of 25%reduction
product according to manufacturer specifications.
*New septic system MUST remain 50 feet from existing well(shown on site plan).
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Not Required, has space Soil LIAR: g.p.d.lft2
Proposed System:
System Classification:
ehpcnnit 03/20/2023 14:26