Loading...
HomeMy WebLinkAboutAUTH-02-2023-188977.TIF z.`• CATAWBA COUNTS' j.. Public health Department Subdivision LYNMORE Environmental Health Division PINK 460904824173 PO Box 389,25 Government Drive,Newton,NC 28658 LOTS 7 tat 9' Site Address: 2106 LYNMORE DR, SHERRILLS FORD NC 28673 Name on Permit MICHAEL HAMBY Property Size: Acres 1.08 Directions: HWY 150 East to left Sherrills Ford Rd turn right Mollys Backbone,left Lynmore. Property on right. Owner/Authorized Representative Acknowledgement of Permit Receipt certify that I am the owner or authorized agent(owner's authorization required)representing the owner of the property described above. • !, As the property owner or authorized representative, I have received the above referenced it(s)as requested in the application for service EHPR-11-2022-42900,by the following method(s): Received in Person _,_ Facsimile Transmittal (Return form with signature required) 4 Electronic Image Transmittal/E-mail (Return receipt required) t e property owner or authorized representative I have reviewed and understand the specific conditions )(, e permit issued, and further understand that all applicable regulatory requirements specified under the North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900), and/or Well Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and the construction of the wastewater system and/or water supply well permitted. Permit Issue Date:02/10/2023 :::eruth01. 1 Representative Documentation of Permit(s)Transmittal (permit transmitted by electronic or other means) Permit transmitted by _ _ (name of person sending permit) Signature qf Date/Time J Method: Fax ./ Email US Mail Other Owner's request to send by the above indicated method of transmittal in lieu of signature We wantt tto hear from yoiPlease ttake a few momentts tto complette our custtomer service survey att http://www.surveymonkey.com/s/EHCusttomerService hOrON ch69 lit . e I'm- c bed 5r4d, r,y0g Atild ear iIc6prmw 02/10/2023 11.18 /, • CATAWBA COUNTY Case# AUTI-l-02-2023-188977 Public Health Department Subdivision LYNMORE Environmental I lealth Division 460904824173 PO Box 389,25 Government Drive,Newton,NC 28658 i O1'# 7 8, sw Site Address: 2106 LYNMORE DR, SHERRILLS FORD NC 28673 Name on Permit: MICHAEL HAMBY Property Size: Acres 1.08 Directions: HWY 150 East to left Sherrills Ford Rd turn right Mollys Backbone, left Lynmore. Property on right. Authorization to Construct Permit Permit Category: Expansion Wastewater Flow: 360 g.p.d. Type of Facility: Primary Residence- Basement? Yes Basement Plumbing? Yes Bedrooms: 3 Water Supply: Public Water Maximum Occupants: 6 Soil LIAR: .3 g.p.d./ft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 25% REDUCTION System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS Septic Tank: New Tank: 1.000 gal Pump Tank _gal Grease Trap_gal Dosing Volume gal Pump Specs: GPM @ TDH Pressure Head ft Draw Down in Drainfleld: Total Area: 300 sq ft Total Trench Length: 100 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center Number of Drain Lines: 1 Trench Width: 3 ft Distribution: Distribution Box Pre Treatment: NONE Additional Specifications: *Expansion from 2 Br(permit# 12766, dated 1/7/82)to 3 Br septic system. *Do not cut,drive, fill, or grade over septic or repair areas. *Septic system must be 10 ft from property lines, 15 feet from basement cuts, 5 ft from building foundations and appurtenances, and out of right-of-ways and easements. *Install a new 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface). Existing septic tank should be pumped out, crushed, and filled in with soil. *After septic tank install a new 3 outlet distribution box. 2 outlets should feed the existing bed and the other should feed the new line. *Install 100 linear feet of 25% reduction system, proposed 1 line on contour. *Final grade of septic area must shed surface water off and away from system. *All gutter drains must be routed away from the septic system. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Required Soil LTAR: 0.275 9•p•d.ift2 ,lipunui 02 20 2023 08.54