HomeMy WebLinkAboutAUTH-02-2023-188919.tif 094
CATAWBACOUNTYCase# AlJ'1'II-02-2023 188919
Public Health Department Subdivision LAND HARBOR
Environmental Health Division PIN# 369720707589
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 7
Site Address: 6932 NAVAJO TR, SHERRILLS FORD NC 28673
Name on Permit: DENISE PODAVINI
Property Size: Acres 0.48
Directions: Hwy 150 towards Mooresville, L @ Country Store, past Fire Dept,2nd R is Navajo Trail
Owner/Authorized Representative Acknowledgement of Permit Receipt
I certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
`/ .,� /e property described above.
K � As the property owner or authorized representative, I have received the above referenced
f permit(s)_ as requested in the application for service RBPR-08-2021-38470, by the following method(s):
xReceived in Person
Facsimile Transmittal (Return form with signature required)
Electronic Image Transmittal/E-mail (Return receipt required)
V_
As the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900),
and/or Well Construction Standards(15A NCAC 2C .0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 02/09/2023 /�
Owner/Authorized Representative Signature �y��d� etyA---
Date i/2/,
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of person sending permit)
Signature_ Date/Time
Method: Fax Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yoaPlease ttake a few momentts tto complette our custtomer service survey att
http://www.surveymonkey.com/s/EHCusttomerService
IfLe
cikih milt 02/09/2023 13:20
.11w\•l CATAWBA COUNTY Case b AU II 1-02-2023-188919
Q -r ii . Public Health Department Subdivision LAND HARBOR
„101� limironmental Health Division PIN# 369720707589
PO Box 389.25 Government Drive.Nc‘\mn.NC 28(58 L(11'# 7
IH.
Site Address: 6932 NAVAJO TR, SHERRILLS FORD NC 28673
Name on Permit: DENISE PODAVINI
Property Size: Acres 0.48
Directions: Hwy 150 towards Mooresville, L @ Country Store, past Fire Dept,2nd R is Navajo Trail
Authorization to Construct Permit
Permit Category: Relocation Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LIAR: .4 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1,000 gal
Pump Tank 1.000 gal Grease Trap_gal
Dosing Volume 110 gal Pump Specs: 23.92 GPM @ 11.2 TDH
Pressure Head 2 ft Draw Down 5.25 in
Dralnfield: Total Area: 135 sq ft Total Trench Length: 45 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 1 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
*Permit issued for relocation of tank and partial existing drain field to allow for new addition plus deck to rear of
existing house footprint.
*Keep all parts of septic system and any future repair minimum: 50'from any individual well, 10'from property
lines, 5'from deck, 5'from garage, 10'from any building foundation requiring a foundation drain.
*Existing gravel drain field has three 80'trenches. 15' of each trench to be cut off to meet setbacks to new
addition and deck. A new 45'trench of 25%reduction to be installed to replace drain field removed. Due to depth
of existing lines,a pump will be required to a schedule 80 pressure manifold with(4) 1/2"schedule 80 taps.
* Each existing trench shall be compacted at the end of the trench with clay where it has been cut off. The
existing gravel trenches shall be fed by sleeving the 3 inch pvc(from the manifold)into the existing 4 inch
corrugated a distance of at least two feet.
*The lot is repair exempt and was recorded in 1971. Plat attached with plan case. Partial repair has been
designated for the new line that is being installed to make up existing drain field that is being removed.
*Call EHS at 828-244-0943 minimum 1 week prior to installation for a preconstruction conference.
0210 2023 15:19
1 t
CATAWBA COUNTY Case# AUTH-02-2023-188919
• .t. Public Health Department Subdivision LAND HARBOR
• .� Environmental Health Division PIN# 369720707589
Aptirt 111
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
v+
Site Address: 6932 NAVAJO TR, SHERRILLS FORD NC 28673
Name on Permit: DENISE PODAVINI
Property Size: Acres 0.48
Directions: Hwy 150 towards Mooresville, L @ Country Store, past Fire Dept,2nd R is Navajo Trail
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LIAR: .4 9•P•d./ft2
Proposed System: 50%REDUCTION VERTICAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (15A NCAC I 8A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
dL— il
02/09/2023
Authorized State Agent Permit Issuance Date
12/16/2026
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
cl i,.n n t 02/09/2023 13:20
ce } a 3c=yXd . _ kd i
t+ ?`•.J ,fr;lit 'L '`S. , ,..,J, ..
Catawba County Environmental Health
J it
r(.9 C N
(" /p
i`
V„ '�1
.r� I �� / C
• x4. Epp N-ew is 0 'r •6940
.1 6S_6}' :/:,y
Q,
3T 7�,
5/ „,..... •6932
®
Pr s
N V it
N �
N 6
eo V
0.
J ` 0�
a
,O
a
27.
•6920
8 rP
�b� �' yip
Parcel: 369720707589, 6932 NAVAJO TR 1 in=40ft
SHERRILLS FORD, 28673
1MPy - (2- - - I _ 147_ C.aG
44 UT N 9
This map/report productfweb preps from the Catawba County.NC Geospatial Information Services. Catawba County has made substantial afford
to ensure the accuracy of location and labeling Information contained on this map or data on this report Catawba County promotes and recommends
the independent verification of any data contained on this map/report product by the user.The County of Catawba,Its employees,agents,and
personnel,disclaim,and shall not be held fiable for any and all damages,loss or liability,whether direct,indirect or consequential which arises or may
arise from this map/report product or the use thereof by any person or entity.
Copyright 2021 Catawba County NC
I
02/02/2023
Scanned with CamScanner
C .1c_ C931 Hcvc3o Tr�u
I
+ , ,� Lrp Q
r Fr. N. a,
k 1{S / L`lo = b. I%1S to 0 or sys "^
A 36o Spa X ° . "Lk) — 5
? L pa �.� •�I LTIq Q r re_f I. c ,.•,-.�-�- 4'1.1.., ..k
= I�b /glrFP�r Zsfc = ys . c
1 �, F I • L, urea.
r`Pa r. Q.X� h PC-5 1 q I^4 f 1n 1
S
lei-o9�
• p. r- rt.-p l«' M "�- t . q4e. i L.T.A
Cti
-7L. 5 (a f . LTR I$o / 3 = 6oXo.s- = 3co 5070
gaa . t' ar r -p.sr . A (O )(LI0' o r•-o.
aL,w,� a r• 7�h"1 �� - r rL.q
LYO L.F. (J r• :,�.�i� k
I dY ^•
'
1112 . $o •}-,ps s 2 1 •4 L p M
5 . 2-r f a w O v/ Ct 4- Z t cl a I p-r
tOuo c,ctl3r\
Scanned with CamScanner
20
CALCULATIONS
Location
Project Number
Lot No:
No. of Bedrooms 3
Design Flow 360 gal/day
LTAR 0.4 9al/ft2day
EZ-Lay? (YES OR NO) NO
Supply Line Length 70 ft.
Supply Line Volume 12.18 gal. FRICTION FACTOR
INTERPOLATER
Required Feet of Line TO ft. 2"SCH 40 PVC
Amount of Line from Layout 4S, ft. GPM f
20 0.84
Gallons per Minute 21.92 gal/min -0.88
25 1.27
Required Septic Tank Capacity 1000 gal. -1.28
Minimum Standard Tank Size 1000 30 1.78
-1.76
Lateral Line Volume 146.925 gal. 35 2.37
-2.25
Dosing Volume 110.00 gal. 40 3.03
Note: Dosing Volume based on 70% 43.07 3.48
of the lateral line volume. 45 3.77
48.14 4.28
50 4.58
57.11 5.89
60 6.42
Tank Draw Down 5.2 Generic Draw Down of 21 gal.per in.
Pump Run Time 5.02 minutes
Elevation Head 10 ft.
Pressure Head 2 ft.
Friction Factor 1.27 ft./100 ft.(From the interpolater.)
Friction Head 0.89 ft.
Total Dynamic Head (+15%) 14.82 ft.