HomeMy WebLinkAboutAUTH-01-2023-187466.TIF ,CCATAWBA COUNTY Case# AUTH-0 1-2023-1 87466
.'.� , , Public Health Department Subdivision
d „� '� Environmental Health Division PIN# 362810276416
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
8.
Site Address: 2531 CATTLE CREEK FARM RD, NEWTON NC 28658
Name on Permit: DENNIS LUTZ
Property Size: Acres 4.81
Directions: NC 10, left onto Startown Rd, right onto Rocky Ford Rd, left onto Cattle Creek Farm Rd
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-Repair
Basement? Yes Basement Plumbing? Yes Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LIAR: 0.3 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1.000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 906 sq ft Total Trench Length: 302 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not drive,grade, cut or fill over any part of the septic system area.
*Existing septic tank may be used IF it meets the current rules, is in good condition, and placement allows for
proper gravity distribution of effluent.
*If existing septic tank is not used, it MUST be properly abandoned (pumped, crushed and filled).
*Install 302 feet of 25%reduction product according to manufacturer specifications.
*All parts of the septic system area MUST remain 5 feet from building structure, 10 feet from property lines and
water line.
*Shared well is at 2590 Cattle Creek Drive.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions ««<
PROPOSED REPAIR
Repair System Required? Not Required Soil LIAR: g.p.dJft2
Proposed System:
System Classification: