HomeMy WebLinkAboutAUTH-12-2022-186768.TIF p,: CATAWBA('OU�NTY Case At Ili 1-1 2-2022-1 86768
� . Public Health Department Subdivision
let(, Environmental Health Division PIN# 363905082904
Pt)Box 389,25 Government Drive.Newton,N(' 28658 Loi# 1
/8R/w
Site Address: 1471 SIMMONS ST, NEWTON NC 28658
Name on Permit: BARBARA ANGELONI
Property Size: Acres 6.84
Directions: Hwy 10, Right on Simmons t, property on Left
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-New House
Basement? Yes Basement Plumbing? Yes Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LTAR: 0.3 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: 111G-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 912 sq ft Total Trench Length: 304 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 24 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 4 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Pump *May Be* Required
Additional Specifications:
*Do not drive, grade,cut or fill over any part of the initial or repair septic areas.
*Install new 1000 gal septic tank and 304 feet of 25%reduction product according to manufacturer
specifications.
*All parts of the septic system area MUST remain 15 feet from house location(due to basement), and 10 feet
from property and water lines.
*If plumbing depth does not allow for gravity dispersal of effluent a pump may be required.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 9•P•d./ft2
Proposed System: 25%REDUCTION
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Pump Required
01!13F2023 09:14