HomeMy WebLinkAboutAUTH-12-2022-186252.TIF CATAWBA COUNTY Case it Mill 1-12-2022-186252
• .f.EL Public Health Department Subdivision
Environmental Health Division PINt1 269802649098
PO Box 389,25 Government Drive,Newton,NC 28658 LOP,
• s m
Site Address: 5313 PEACE HAVEN RD, NEWTON NC 28658
Name on Permit: *ISAIAH SHEFFIELD
Property Size: Acres 1.91
Directions: Right off of Plateau Rd onto Peave Haven Dr. Last lot on left.
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 240 g.p.d,
Type of Facility: Primary Residence-New House
Basement? No Basement Plumbing? No Bedrooms: 2
Water Supply: Private Well Maximum Occupants: 4
Soil LTAR: 0.25 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: LOW PROFILE CHAMBER
System Classification: IIIB -SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1,000 gal
Pump Tank 1.000 gal Grease Trap gal
Dosing Volume 147 gal Pump Specs: 36.91 GPM @ 19.13 TDH
Pressure Head 2 ft Draw Down 7 in
Drainfield: Total Area: 960 sq ft Total Trench Length: 320 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 14 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
*Permit issued off a2 soil scientist submittal (IMPV-10-2022-182862).
*Install new 1000 gal septic and pump tank, along with 320 feet of Low Profile Chambers according to
manufacturer specifications.
*Do not drive,grade,cut or fill over any part of the initial or repair septic areas.
*All septic areas MUST remain 10 feet from property lines, 15 feet from building structure (if there is a foundation
drain),and 50 feet from proposed well location.
*Pressure manifold sheet attached.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.25 g.p.d.lft2
Proposed System: LOW PROFILE CHAMBER
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Pump Required
,1 gsrn-u i 12,16/2022 16:01
r
N.)01 , 3
CD
O 0
O
w o
m
a
r.
II
v
In c O
°• 3 ,u(Di m
-1 TIN ONNmm O
C
-I
-a A
> co 3 w
II
ca
13
f) rnnnn = co
o A N Z = 2 2 i O ac D
N o 0 3 0 0 0 0 o cD
cn
_ _ _
w .� F.
II r s I.i rJ 1= t,3 CD C
CD
7
T X
a
t0 co -u -1. s -1. =1
CD
9
A j N PO NJV CO COO CO
Q) (D A A A A E.
A N A A O A
-1
10 N
Q) -+ _, N I„, C=)
O N co 00 W O 5
C O CP m A A >
CD
Iv
n
0
O O O O O O <
CI) CT T V r
CT C A -1
D
xi
N
(n
O e
r
0 0 0 0 0 >
x
w o
01
0
o e
b r
O0 0000o D.
0 0 0 0 0 x
V CO CO CD V
a)