Loading...
HomeMy WebLinkAboutAUTH-12-2022-186051.tif (144 catawba county public health May 30, 2025 Shannon Gentry 1466 Victorian Hills Cir Conover, NC 2861 3 Subject: Notice of Intent to REVOKE the Authorization to Construct Repair for 1466 Victorian Hills Cir, Conover NC 28613; PIN: 374410463139. Catawba County Permit AUTH-12-2022-186051 Dear Property Owner: The Environmental Health Division of Catawba County Public Health intends to revoke your Authorization to Construct 30 days from the date of this notice. You must apply for a new Authorization to Construct and meet the requirements of the current laws and rules necessary to obtain a new Authorization to Construct. You have a right to an informal review of this decision.You may request an informal review by the environmental health supervisor at the local health department. You may also request an informal review by the Department of Health and Human Services' Regional Soil Scientist. A request for informal review must be made in writing to the local health department. You also have a right to a formal appeal of this decision.To pursue a formal appeal, you must file a petition for a contested case hearing with the Office of Administrative Hearings, 1711 New Hope Church Rd, Raleigh, NC 27609. You may write the Office of Administrative Hearings, call the office at 984-236- 1850, or get a copy of the petition form from the OAH web site at http://www.oah.nc.gov.The petition for a contested case hearing must be filed in accordance with the provision of General Statutes 130A-24 and 150B-23 and all other applicable provisions of Chapter 150B. General Statute 130A-335(g) provides that your hearing will be held in the county where your property is located. If you wish to pursue a formal appeal, you must file the petition form with the Office of Administrative Hearings WITHIN 30 DAYS OF THE DATE OF THIS LETTER.The date of this letter is May 30, 2025. Meeting the 30-day deadline is critical to your formal appeal. If you file a petition for a contested case hearing with the Office of Administrative Hearings, you are required by General Statute 150B-23 to serve a copy of your petition on the Registered Agent for the Department of Health and Human Services:Julie Cronin, Office of General Counsel, Department of Health and Human Services, 2001 Mail Service Center, Raleigh, N.C. 27699-2001. catawbacountync.gov Environmental Health Catawba County Government Center 25 Government Drive PO Box 389 Newton NC 28658 828.465.8270 MAKING. LIVING. BETTER. Do not serve the petition on your local health department. Sending a copy of your petition to the local health department will not satisfy the legal requirement in General Statute 150E-23 that you send a copy to the Office of General Counsel, 2001 Mail Service Center, Department of Health and Human Services. Respectfully, P 7 Robbie Phelps, REHS Environmental Health Supervisor Catawba County Public Health r a rtr,ltfi7 c,�ta trtallc' !t . I�r�illd„lF-F'1'rW�Ltrn�trr�,rrYr'lar►Tttirtr ArI`1[,S.t tali r r _,_� IAILtotr- -- �, r"'- c t 0----'°---—"_'—.--- ti tip+ n� . ., " it)1 1 `---� Dale lsa ed, 12.:.k10,97/ -_., u.7 �� t Prof �"� Arm!_�1:2 td-69. -- �i+ �'a"t fhrw�tth c tdnrtlb _ efts p�+. ,c,n*�`' Atoll � �� r41 rnl.y retimrN� 'tPM � rQ pig 15�rii=23x1�y5! ` applies.r w _r Statute I VA44 and aushorriz test and ct= a. od woo �� ar Lro E pormuarti far e it[ot r. � 'nlfJt "'�'€ 6°16"� ne wan IbcomPi Oda 1 that O t Q r� [r fr►r J " c ,�a t !_ �l fry#dia —__�� r (Sydoxi ,cachet heath g` by a a�matt es esv wit can he�ysen ied to the Mirth C r ro9ir+a C11`Lee coY A. ` , re -441 M,,,n iri�rt a rar►cn t s ,,,y�tiur*or Pe ,sfu ramlih tSef }ur3uanc t4 ther atr►larta A4m ictisLrrtt?vie'P�r art rc t, 4 Uis�lstlUant9 ealth �, ran rP r ftho rep' th Ghat the�carr Nord: .must tie ntYoked. 1 understand nd th 5 that time ghat't Juow otia n 3c „ Omar adJ char rbo revocation at, if the revocation is apt �' r "� u- . . o [" ies la fir wad is d . x froth trysigning.this form and r lrevocation fay kitt U) alprP „n is of istra decisive. I understand the f health department's r ,�e { r4 Administrative e revocation of a permit that takes effect immediately is in r . 'hest'tale �'�' �[rba ` and nfi► that appeal the pi•nttit revocation. arnotflo ` r td fhart t J.y pt to f�F . rt��'►�rtr�Y ttrr"s Mg� 1° art�vst{9n�,rlr� to rot t t do �t si ren 1rightstautthatthisis.unopiit we required to g li b'my'PP t f tar rhsh ocs-tionof p it to take circa - ar LW .3. , eatawbacountync.gov Eavkronmenlol health Capawbu (minty Govtrlineol (Inter w 25 Geopromerit Drive I PO Box 389 I New-1 n NC . MAKING. LIVING. 0E11E11 , .... ...... .,.. Robert Phelps From: shannon (null) <shannade@yahoo.com> Sent: Friday, May 30, 2025 4:25 PM To: Robert Phelps , Warning: Unusual sender<shannade@yahoo.com> You don't usually receive emails from this address. Make sure you trust this sender before taking any actions. x i Vt 1‘,WAVII s W ‘ IA 1. X =, 4L Li 1, \ '' 7.k :k' \ — • , ', \\ -* i.e , A ti Tel'''.>1 - %. \ IV s. c't, \T,, , :, ' ',Ti Z C. gZ ag -u % % \\I \ \ ')i � r Nc4-- ik .1 '10 ‘ , e ¢' - . 9 13R }r 4t -R't 3' 1 71. ...„ . K. %5.... a ,l tin es 0 740 v ca Z \ X' \ ' oV; t CS C• Ft .% ok? iAG m t. am De J. p n £• C AI - I CP ic/g y n p ... r ft J01 Sent from my iPad t rya' CATAWBA COUNTY Case# AUTI1-12-2022-186051 ti .t. Public Health Department Subdivision VICTORIAN HILLS v, O `e Environmental Health Division PIN# 374410463139 / PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 25 I842 sm Site Address: 1466 VICTORIAN HILLS CIR, CONOVER NC 28613 Name on Permit: SHANNON AND STEVEN GENTRY Property Size: Acres 0.48 Directions: County Home Rd at round about take 2nd exit,turn right onto Lee Cline Rd, left onto Victorian Ct. home is on the right Owner/Authorized Representative Acknowledgement of Permit Receipt I certify that I am the owner or authorized agent(owner's authorization required)representing the owner of the property described above. t As the property owner or authorized representative, I have received the above referenced permit(s)as requested in the application for service EHPR-03-2022-40376,by the following method(s): Received in Person Facsimile Transmittal (Return form with signature required) JElectronic Image Transmittal/E-mail (Return receipt required) As the property owner or authorized representative I have reviewed and understand the specific conditions of the permit issued, and further understand that all applicable regulatory requirements specified under the North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900), and/or Well Construction Standards(15A NCAC 2C .0100), shall apply to the issuance of this permit and the construction of the wastewater system and/or water supply well permitted. Permit Issue Date: 12/12/2022 Owner/Authorized Representative Signature Date Documentation of Permit(s)Transmittal (permit transmitted by electronic or other means) Permit transmitted by — (name of person sending� permit) Signature Date/Time 1'l+lt C , Method: Fax Email US Mail Other Owner's request to send by the above indicated method of transmittal in lieu of signature We wantt tto hear from yoiPlease ttake a few momentts tto complette our custtomer service survey aft http://www.surveymmonkey.com/1s/EHCusttomerService hCi Q�' 'vl A I i ehpenuii 12/13/2022 14:22 . CATAWBA COUNTY Case# AUTH-12-2022-186051 Public Health Department Subdivision VICTORIAN HILLS ,,,mt t Environmental Health Division PIN# 374410463139 PO Box 389,25 Government Drive.Newton,NC 28658 LOT# 25 PitI. Site Address: 1466 VICTORIAN HILLS CIR, CONOVER NC 28613 Name on Permit: SHANNON AND STEVEN GENTRY Property Size: Acres 0.48 Directions: County Home Rd at round about take 2nd exit, turn right onto Lee Cline Rd, left onto Victorian Ct, home is on the right Authorization to Construct Permit Permit Category: Repairs Wastewater Flow: 360 g.p.d, Type of Facility: Primary Residence- Existing House Basement? Yes Basement Plumbing? Yes Bedrooms: 3 Water Supply: Private Well Maximum Occupants: 6 Soil LIAR: .225 g.p.d.Ift2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 50%REDUCTION HORIZONTAL System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION Septic Tank: Existing Tank 1,000 gal Pump Tank 1,000 _gal Grease Trap_gal Dosing Volume 137 gal Pump Specs: 29.47 GPM @ 15 TDH Pressure Head 2 ft Draw Down 6.5 in Drainfleld: Total Area; 876 sq ft Total Trench Length: 292 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 14 in Minimum Soil Cover: 6 in Minimum Trench Separation: 6 ft on center Number of Drain Lines: 5 Trench Width: 3 ft Distribution: LPP Pre Treatment: NONE Pump Required ***** Operator Required Additional Specifications: 'Bring in 10 inches of clean group III soil for cover. 'Call Catawba County EH at least one week before installation to have a preconstruction meeting and to re-flag the drain lines. Call 828-320-3077. "Install 66 horizontal blocks total. "Install a valve to allow future alternation between drain fields. "If needed relocate the existing supply line and straight pipe the new trenches across the old supply line trench. "Use 5/32"holes in the distribution pipe "Only one pipe through the uphill side of the block is needed for LPP distribution. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Soil LTAR: g.p.d.lft2 Proposed System: System Classification: rhpri 12/14R022 i 5:2I CATAWBA COUNTY Case l! AUTFI-12 2022-186051 i Public Health Department Subdivision VICTORIAN HILLS ..fl e Environmental Health Division PIN# 374410463139 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 25 I Site Address: 1466 VICTORIAN HILLS CIR, CONOVER NC 28613 Name on Permit: SHANNON AND STEVEN GENTRY Property Size: Acres 0.48 Directions: County Home Rd at round about take 2nd exit, turn right onto Lee Cline Rd, left onto Victorian Ct, home is on the right The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (15A NCAC I 8A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. fki,(,„ 12/12/2022 Authorized State Agent Permit Issuance Date 12/12/2027 Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department. ehlsennit 12/13/2022 14:22 Catawba County Environmental Health Ab-th - (2- 7oz1- fg` oc qq 100.0i r -,_ __ F��c.c ` alki I *Install 66 horizontal T&J panel blocks total. f 45ft=10 blocks,63ft=14 blocks,and 80ft=18 blocks, I b1 r� 68ft=16 blocks,and 36ft=8 blocks. n *Use 5/32 inch hales in the distribution pipe drilled at ~ / ` the 10 and 2 o'clock positions.Drill one hole per block. *2 feet of pressure at the end of each line. m f 0+ *Rake and lime the side walls c. �X�I)(614f1 (I.:, �O /� *Use approvedbackfillsand. in *Seal both the outer and inner compartments of the T&J ' C'� panel with foam.The outer seal is a complete seal and ,�� the inner seal is only up to the top of the connecting pipe. g�, ,$ IA" 1 A �b� I !` b I � N v irun de(h it 5 62. /ki------„z9:...- ______4 /I p�' iiuuaft, •1466 ftilly 100,17 v'y\l 1it.17 • ��� gj ,f� ViC7ORIAN NUS Cm Parcel: 374410463139, 1466 VICTORIAN HILLS -__1:, 1 in=4011 CIR CONOVER, 28613 ~—T---_...___ This map/report product was prepared from the Catawba County,NC Geospatial Information Services. Catawba County has made substantial efforts to ensure the accuracy of location and labeling information contained on this map or data on this report.Catawba County promotes and recommends the independent verification of any data contained on this map/report product by the user.The County of Catawba,its employees,agents,and personnel,disclaim,and shall not be held liable for any and all damages,loss or liability,whether direct,indirect or consequential which arises or may arise from this map/report product or the use thereof by any person or entity. Copyright 2021 Catawba County NC 12/12/2022 DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Shed of DIVISION OF ENVIRONMENTAL HEALTH PROPERTY ID#: ON-SITE WASTEWATER SECTION COUNTY: SOIL/SITE EVALUATION , for ON-SITE WASTEWATER SYSTEM OWNER: (2-ha AO Oh i S4 e\le"bt11-1(1 APPLICATION DATE -.1 I I ?1 Eflek-03-7_622_YO376 ADDRESS: DATE EVALUKTD: fizz 2.11,6( —Pk()P9SEE3 FACILITY: 3 Sig 40uSf., PROPOSED DESIGN FLOW(.1949): 317C's PROPERTY SIZE: 0,II%rgreS g q1-21- LOCATION OF SITE: i ictorinn tills (ir, Cor\OVer PROPERTY RECORDED: WATER SUPPLY: tif Private 0 Public 0 Well 0 Spring I] Other EVALUATION METHOD: fil Auger Boring fril Pit 0 Cut TYPE OF WASTEWATER: )1 Sewage 0 Industrial Process 0 Mixed . • • • '...- .................... ;;7E ..... ,.....:1:7: ................------ .:.::::: ..:...-........•••-,. ::::.....:.::::::::::::: ::-...i; ...:...................... SOIENTORMOIDTV.-......................... .ili :)TTEER. iirii:............................, ' (1941) ...... .. .......41100.17.11Ltike.EORS Tlii4....19A V.'.-,'.!:.::.!z.'" . --- • , ........................ 41111!TAIAM)... ::110B1f.!::: ....... •••••........ 94 •,iiii :::::: . zwi ..... .......d.94tP;...................... ...f':10.41 '.!. ......:::4. SOIL..............4941:-. ........11.56....... gttittow Ebirtii. :....:::StIttICTUREI.........---CONSISTINCV:..::f iNAYrrxr..ssx........SOXIalE;....:;Sktigt)2 !!1;t5Tst:::::::.:: -IT $_.. : 'iiiiiii !..sLogEd•ic; giIN.Y..... :....i':::;11.03lin....!:!'.!!!'....f MINZRAttitii PPIAtilt.....iii:DEETECiil....C..VAS$H:i :..!!1;30Riz::::iiiit:LTAR' _ r, i ( _ L 6, .r. 1 r 10 04? , ' 1 I L ,61- qg C • 13 li Al6k r . 1 / 1 1 l/1 tr/Z- LI Lf i .. i/ 74-4 g ' L 6; 5 2.44 C r t‘ i... Jr .y Jr lir , 0,211. 2 ' ' '' 'Pi_ $-2_ C Ai 11 1.i ‘• 1 .) I-ix. / ) el e elz , _.1 7_ . 2:5- r; 11 )0 Vf h _ 01. 4-‘2, 1.- 6 a' „ ( r') - 7---51 IT / 3 i 11--)-i- c 0 ,,c4..., r, „ , n r 1,, - 7r 1-1,- "A-S-9 C i v, kil II I&A 0 t f q I 1 i. ]fig ( ftir C a D IP J c L is'kfill I- .5-iiii JL Woh rr i J4fp pp-xil Li g ... , z , 4 36-41 c A-iiiii t, ) 51, fetrIxt DESCRIPTION INMAL SYSTEM REPAIR SYSTEM OTHER FACTORS(.1946): SITE CLASSIFICATION(.194E): a- Available Space(.1945) 8 e • Syst=Typ*) 5°e/. if EVALUATED BY: f. ‘ix Pits4,- - OTHER(S)PRESENT: au ir4 givr Pot i;2- 7 Site LIAR , -r -f,e,dA (In OC..11.- /16 ft 6 COMMENTS: SOIL/SITE EVALUATION Sheet of (Continuation Sheet-Complete oilfield inJull) PROPERTY ID#: DATE OF EVALUATION: COUNTY: s r P , R SOIL MORPHOLOGY OTHER F (.1941) PROFILE FACTORS 1 .1940 — L LANDSCAPE HORIZ 1942 .1956 .1944 PROFILE POSITION/ ON .1941 .1941 SOIL .1943 # SLOPE% DEPTH STRUCTURE/ CONSISTENCE/ WETNFCSI SOIL SAPRO RESTR CLASS (IN.) TEXTURE MINERALOGY COLOR DEPTH CLASS HORIZ &LTAR r? —q rt Gr 5 a r4F 17° Jc 1 f,�/1 rY( iJ rp 72 ” C ..11"-1/4 1' fl I IJ'44( 1°y1j 2 h 4 - 0-Z0 Icl- r'- r,strT: \ �i 70-WI- J C. v..e .I1 Fri S+ Ji foe j 3 L 7 �-i 7 3 C „40 h F}Il fii+f.•V LIT . ??T F ? C)M MEN"fti: Updated February 2014 Catawba County Environmental Health a moo' �• , /' �� r / -� ry/ i �y, o % ° �� -7 9g ``rP /r oa o° v e) J / 100 1 V 9a1 `3 _,�� ` '. ,... I i 1. / ri / § 1 I t ( :Ail ‘ 1 ,2/ Pia ,::: 744° , \ / ... i s. \ . \ i .. (213) to cn III 4' ,i h it � .11( Ail CK li \4). I \, 100 100. \\:\ \ • / ,/ • 14\ \ 710R14N HILLSCIR \� \ '`� //-08-988 �. 4\ Parcel: 374410463139, 1466 VICTORIAN HILLS tin=40ft CIR CONOVER, 28613 This map/report product was prepared from the Catawba County,NC Geospatial Information Services. Catawba County has made substantial efforts to ensure the accuracy of location and labeling information contained on this map or data on this report.Catawba County promotes and recommends the independent verification of any data contained on this map/report product by the user.The County of Catawba,its employees,agents,and personnel,disclaim,and shall not be held liable for any and all damages,loss or liability,whether direct,indirect or consequential which arises or may arise from this map/report product or the use thereof by any person or entity. Copyright 2021 Catawba County NC 12/12/2022 Robert Phelps From: Brad Johnson <brad@tjpanel_com> Sent: Wednesday, December 14, 2022 9:08 AM To: Robert Phelps Subject: Re: 1466 Victorian Hills Cir This is an external email. Please be cautious before clicking any links or attachments. If you have questions about this email, please send them to suspiciousemail@catawbacountync.gov Hi Robbie, Yes, 2 gallons per panel would be just fine especially because you are using LPP distribution. We need that minimum dose of 3.6 when utilizing pressure to gravity to get better down line distribution. Also, I am trying to get a time that may suit your staff to make myself available. I Just wanted to go over panel block, designs, and questions that may help you guys in the future. Let me know what you think we could make happen.Thank you so much for all you do! Brad Johnson On Dec 14, 2022, at 8:47 AM, Robert Phelps<RPhelps@catawbacountync.gov>wrote: Hey Brad hope you are doing well. I am designing a repair system that will utilize horizontal blocks with LPP distribution. I am installing valve that will allow future alteration between the initial system and this repair field. I need to dose the t&j Horizontal blocks at around 2 gallons per block per dose. This dosing volume would accommodate the existing drainfield when the valve is switched back. I'm trying to avoid having to adjust floats when alternating fields. Is the 2 gallons per block ok for the horizontal blocks in this scenario? Thanks for your help. Robbie Phelps, REHS Environmental Health Supervisor, OSWP Division 25 Government Drive, Newton, NC 28658 (828)320-3077 cell https://www.catawbacountync.gov/county-services/environmental-health/ efcatawba county Confidentiality Statement:The information contained in electronic transmissions is confidential and may be subject to protection under the law,including the Health Insurance Portability and Accountability Act(HIPAA).An electronic transmission is intended for the sole use of the individual or entity to whom It is addressed.If you are not the Intended recipient,you are hereby notified that any use,distribution or copying of the message is strictly prohibited.If you received a message in error,please contact the sender immediately by replying to the e-mail and delete the material from any computer. 1