HomeMy WebLinkAboutAUTH-12-2022-186018.TIF =fie CATAWBACOUNTY Case# AUTII-12-2022-186018
F. 1, y Public Health Department Subdivision WYNSWEPT PH 3
Environmental Health Division PIN# 367804616655
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 56
w
Site Address: 4594 NORTH WYNSWEPT DR, MAIDEN NC 28650
Name on Permit: *MIKE PALMER HOMES, INC.
Property Size: Acres 0.76
Directions: Hwy 16 S, left on Cayton Dr, left on N Wynswept,4th lot on right
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LIAR: 0.3 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1.000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 900 sq ft Total Trench Length: 300 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 32 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not cut,drive,fill, or grade over septic or repair areas.
*Septic system must be 10 ft from property lines, 50 feet from wells,5 ft from building foundations and
appurtenances, and out of right-of-ways and easements.
*Install a 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface).
*Install 300 linear feet of 25%reduction system, proposed 3 lines total at 100 ft each on contour.
*Laid out lines 1 and 3 with an inferred line for line 2. Line 1 (yellow) 100 ft, line 2(not flagged) 100 ft, and line 3
(red)100 ft.
*Final grade of septic area must shed surface water off and away from system.
*All gutter drains must be routed away from the septic system.
*Well should be 5 ft from property lines; 25 ft from structures; 50 ft from septic systems; and out of right-of-ways
and easements.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.275g.p.d.ft2
diporut 12/12/2022 11:38
S1Ie CATAWBA COUNTY Case# AUTH-12-2022-186018
ti .t. . Public Health Department Subdivision WYNSWEPT PH 3
, a �� Environmental Health Division PIN# 367804616655
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 56
Site Address: 4594 NORTH WYNSWEPT DR, MAIDEN NC 28650
Name on Permit: *MIKE PALMER HOMES, INC.
Property Size: Acres 0.76
Directions: Hwy 16 S, left on Cayton Dr, left on N Wynswept, 4th lot on right
Proposed System: 50%REDUCTION VERTICAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (15A NC AC I 8A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
tz::5' i ��
'' '
12/12/2022
Authorized State Agent Permit Issuance Date
12/12/2027
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
dip.:null 12/12/2022 11:38