HomeMy WebLinkAboutAUTH-12-2022-185721.TIF $: \ CN'I'AWBA COI.:Nv lnU"I'll-I2-2022-IRS72I
F- j.II ,Z Public Ilcalth Department Subdivision
d . '� Environmental Health Division I'IN# 364914448495
PO13o.e 389,25 Government Drive,Newton,NC 28658 I{)I#
: Z :w Case#
Site Address: 1867 PINE ST, NEWTON NC 28658
Name on Permit: JOSEPH CARROLL
Property Size: Acres 2.47
Directions: St. James Church Rd out of Newton,turn right onto Pine St, 1st house on right
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence- Repair
Basement? Yes Basement Plumbing? Yes Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LTAR: 0.325 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIB- SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1,000 gal
Pump Tank 1,000 gal Grease Trap_gal
Dosing Volume 131 gal Pump Specs: 29.4 GPM @ 32.49 TDH
Pressure Head 2 ft Draw Down 6.25 in
Drainfield: Total Area: 634 sq ft Total Trench Length: 278 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 33 in
Minimum Soil Cover: 20 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
*Do NOT DRIVE, grade, cut, or fill over any part of the septic system area.
*Septic areas MUST REMAIN 100 feet from wells due to saprolite.
*All septic areas must remain 10 feet from property lines, and 15 feet from building structure due to basement.
*Existing septic tank may be used if it meets the current rules and is in good condition.
*If existing septic tank is not used, it MUST be properly abandoned (pumped, crushed and filled).
*Install new 1000 gal pump and septic tank with 278 feet of 25%reduction product according to manufacturer
specifications.
*Pressure manifold tap sheet attached. Use five 1/2"schedule 80 taps
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Not Required Soil LIAR: g.p.d./ft2
Proposed System:
System Classification:
d,,emui 12/15%2022 14:38
ENPR-os-7,..2/-396gs
Avg,_ /2 _7,011 _1y5711 Catawba County Environmental Health
lt:
. 827 ktittl
N 0
NN c �o
iD c�D
.1867
�k A- � 4,
a�9 //I
° *
•kti %-. A
le
Q0
l.r
46t .
"� h
2
Q�
��' �a`b s
43
-40
{LLD,
sii,„ 3
'8S
•1874
4
.,,,$)
.,�7......."-.20
•
Parcel: 364914448495, 1867 PINE ST NEWTON, 1in=60ft
28658
This map/report product wee prepared from the Catawba County.NC Geospauel Information Services. Catawba County has made substantial efforts
to ensuro the accuracy of location and labeling Information contained on this map or data on this report.Catawba County promotes and recommends
the independent vorthcation of any data wnlainort on this mapho orl product by thu user. Thu County of Catawba.Its employees,agents,and
personnel,disdain,and shall not be held liable for any oral all damages.toss or liability,whether direct.Indirect or consequential which arises or may
arise from this rnap/report product or the use thereof by any parson o entity.
Copyright 2021 Catawba County NC
11/30/2022
6
SYSTEM
Line# Color Length Hole Size Flow/Tap gad Trench Area Cony LTAR 25%LTAR 50%LTAR
1 54 SCII801/2 5.48 25.43 162 0.16 0.12 0.08
2 54 SCII 80 1/2 5.48 25.43 162 0.16 0.12 0.08
3 58 S(71801/2 5.48 25.43 174 0.15 0.11 0.07
4 58 SCII801/2 5.48 25.43 174 0.15 0.11 0.07
5 54 SCH 80 1/2 5.48 25.43 162 0.16 0.12 0.08
total feet = 278 gal/min= 27.4 127.14 834.00 0.15 0.11 0.08
Des.Flow 360
Pump Run= 4.64
soil LTAR 0.325