HomeMy WebLinkAboutAUTH-11-2022-184993.tif • CATAWBA COUNTY Case# A[1TH 11 2022 184993
.i.ii
(.... Public Health Department Subdivision WYNSWEPT PH 5.2
Environmental Health Division PIN# 367804713636
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 76
Site Address: 3219 TIMBER RUN LN, MAIDEN NC 28650
Name on Permit: *NEST HOMES LLC
Property Size: Acres 0.83
Directions: Intersection of Buffalo Shoals Rd& NC 16S, NC16S to Left on Cayton Dr, Left on Timber Run Lane
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LTAR: 0.25 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50%REDUCTION HORIZONTAL
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1.000 gal
Pump Tank 1.000 gal Grease Trap_gal
Dosing Volume 252 gal Pump Specs: 30.4 GPM @ 12 TDH
Pressure Head 2 ft Draw Down 12 in
Drainfleld: Total Area: 720 sq ft Total Trench Length: 240 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 21 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 8 ft on center
Number of Drain Lines: 4 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
*Do not cut, drive, fill,or grade over septic or repair areas.
*Permit issued off improvement permit IMPV 11-2020-141744.
*Septic system must be 10 ft from property lines, 50 feet from wells, , 5 ft from building foundations and
appurtenances,and out of right-of-ways and easements.
*Install a 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface).
Install a 1,000 gallon pump tank with risers.
*Will pump to pressure manifold with 4 taps that are sch40 1/2".
*Install 240 linear feet of horizontal PPBPS system, proposed 4 lines total at 60 ft each on contour. 14 panels
per line(56 panels total).
*Lines were originally laid out by Soil Scientist Paul Penninger.
*Final grade of septic area must shed surface water off and away from system.
*All gutter drains must be routed away from the septic system.
*Well should be 5 ft from property lines;25 ft from structures; 50 ft from septic systems; and out of right-of-ways
and easements.
A,,,,,,,, 12/06/2022 I2:09
_e CATAWBA COUNTY Case# AUTII-11-2022-184993
,C •�.12 Public Health Department Subdivision WYNSWEPT PH 5.2
Q - '4 Environmental Health Division PIN# 367804713636
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 76
I sw
Site Address: 3219 TIMBER RUN LN, MAIDEN NC 28650
Name on Permit: *NEST HOMES LLC
Property Size: Acres 0.83
Directions: Intersection of Buffalo Shoals Rd& NC 16S, NC16S to Left on Cayton Dr, Left on Timber Run Lane
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.1 g.p.d.lft2
Proposed System: DRIP IRRIGATION
System Classification: VA-SAND FILTER PRETREATMENT
Pump Required ***** Operator Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility ot'the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (I 5A NCAC I8A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
1
*i ,..-...f
11/22/2022
Authorized State Agent Permit Issuance Date
11/20/2025
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
rhpr,nui 12/06/2022 12:09
A L r (AAA Qg eot 01-'2022.^- 179 t
Catawba County Environmental Health At It- 2.21— ig49/3
WO fc- zz— t$'{Y�Z
297.36
1
•3213
0 VI2CNNA•
8 .
319-96
ILI'
9n P
76
.3s1 d 43.59
s pPf
Zy E_ t,5' SF. `v:v
a:1-
ems'
77
•3225
0
34126
t ; ' ♦4638
Parcel: 367804627661, 3165 TIMBER RUN LN 1 in=50ft
MAIDEN, 28650
This map/report product was prepared from the Catawba County,NC Geospatlal Information Services. Catawba County hes made substantial efforts
to ensure the accuracy of location and labeling information contained on this map or data on this report Catawba County promotes and recommends
the Independent verification of any data contained on this map/report product by the user.The County of Catawba,its employees,agents,and
personnel,disclaim,and shall not be held liable for any and all damages,loss or liability,whether direct,indirect or consequential which arises or may
arise from this map/report product or the use thereof by any person or entity.
Copyright 2021 Catawba County NC
11/17/2022
1
9170
co
4444
I
6666
22
p4p:tzp:
x ctcc x '.I' . S lg�y�
} x x �'1 g O
co � � a
1 22 2 Tig ligEg
z
IUj
M i
i .- N el
20
CALCULATIONS
Location
Project Number
Lot No:
No. of Bedrooms 3
Design Flow 360 gmlidey
LTAR 0.25°M/ftzd.y
EZ-Lay?(YES OR NO) YES
Supply Line Length 75 ft.
Supply Line Volume 13.05 gal. FRICTION FACTOR
INTERPOLATER
Required Feet of Line 240 ft. 7'SCH 40 PVC
Amount of Line from Layout 240 ft. GPM f
20 0.84
Gallons per Minute 28.44°"/,,,i, plus 2
25 1.27
Required Septic Tank Capacity 1000 gal.
Minimum Standard Tank Size 1000 30 1.78
-1.76
Lateral Line Volume 156.72 gal. 35 2.37
72.25
Dosing Volume 252.00 gal. 56 panels 4.5 40 3.03
Note: Dosing volume based on 70% 43.07 3.48
of the lateral line volume. 45 3.77
48.14 ~4.28
50 4.58
57.11 '5.89
60 $42
Tank Draw Down 12.0 Generic Draw Down of 21 griper in.
Pump Run Time 8.86 minutes
Elevation Head 7 ft.
Pressure Head 2 ft.
Friction Factor 1.78 ft./100 ft.(From the interpoleter.)
Friction Head 1.34 ft.
Total Dynamic Head(+15%) 11.89 ft.