Loading...
HomeMy WebLinkAboutAUTH-11-2022-183917.TIF 4.S.rJ>�. (.v:aSro((•rinxry t17 -i-a I'u!d„Hculib i'puruncnl t'r u AI it li-11-2t122-IR1917 ri ,� I nv nnnnn ntid IIvoIth l h,wolf Sutxlis,a,.nt law, IN') `c Jint ornnt�'nr ono! Newlin NI ?NnSN 1'ttwu 379104840862 � PI In f;# A'• Irt1H PT 6-7 Site Address: 6804 HUDSON CHAPEL.RD, CATAWBA NC 28009 Name on Permit: JANE 1 ME NE IRIS it rtaxrn':y St:e: .11wa75 0 Directions: NC 10, right onto HUdsnn Chapot NCI, hornn is On thri Infl Owner/Authorized Representative Acknowledgement of Permit Receipt ill 4 I c'r-tili that I ant the antnertn'nuthorizcd agent ((miler's:tuthtnii,aion rettuited)representin)r thetnvnernI the prosper 1) desi rihra ahtt‘c. xt i As the itrctttcrIY owner or authorized representative, I have received the nbove referenced Troias) as requested in the application thr service EIIIPR-06-2022-4I3%. by the following methrxf(s): Received in Person Facsimile Transmittal (Return Form with signature required) J Electronic Image"Transmittal/ E-mail (Return receipt required) ' ( (i �As the property owner or authorized representative I have reviewed and understand the specific conditions 01 the permit issued, and further understand that all applicable regulatory requirements specified under the " ;North Carolina Laws and Rules for Sewage Treatment and Disposal Systems (I5A NCAC ISA.1900), and/or Well Construction Standards (I5A NCAC 2C .0100), shall apply to the issuance of this permit and the construction of the wastewater system and/or water supply well permitted. Permit issue Date: 11/09/2022 OWnerAuthorired Representative Signature )--e-A--t _ _ _ . _ r Date II 30 ) 90d'D Documentation of Permit(s) Transmittal (permit transmitted by electronic or other means) Pennit transmitted by (name uJ person sending permit) r‘ z► r Date/Time f i ��1'NI Signature \. .- Niethod: Fax J Lnt:ail _US Mail -- _ Other Owner's request to send by the tl 110V c indicated method of transmittal in lieu of signature We wantt tto hear from ymPlease ttake a few momentts tto complette our custtorner service survey att http://www.surveymonkey.con/s/EHCusttomerService jAnt40r �it• 4Ntr1o�'tnc ,CcrA swt-,Y M a .a aV4.�+ Y„ &�&i,,,yr,..Y-4li �� .= . CATAWBA COUNTY Case# AUCH-1 1-2022-183917 H I. Public Health Department Subdivision Q "7R . •<< Environmental Health Division PIN# 379104840862 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# PT 6-7 / .2 ,� Site Address: 6804 HUDSON CHAPEL RD, CATAWBA NC 28609 Name on Permit: JANET MENETRIER Property Size: Acres 0.69 Directions: NC 10, right onto HUdson Chapel Rd, home is on the left Authorization to Construct Permit Permit Category: Repair Relocation Wastewater Flow: 360 g.p.d. Type of Facility: Primary Residence- Basement? No Basement Plumbing? No Bedrooms: 3 Water Supply: Private Well Maximum Occupants: 6 Soil LTAR: 0.3 g,p.d./ft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 25% REDUCTION System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS Septic Tank: New Tank: 1,000 gal Pump Tank _gal Grease Trap,gal Dosing Volume gal Pump Specs: GPM @ TDH Pressure Head ft Draw Down in Drainfield: Total Area: 138 sq ft Total Trench Length: 46 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 32 in Minimum Soil Cover: 12 in Minimum Trench Separation: 9 ft on center Number of Drain Lines: 1 Trench Width: 3 ft Distribution: Serial Pre Treatment: NONE Additional Specifications: *Permit for partial septic system relocation due to barn and fence being placed on top of supply line and top 3 lines of septic system and deck post on top of existing septic tank (repair permit#2008-00262). *Do not cut, drive, fill, or grade over septic or repair areas. *Septic system must be 10 ft from property lines, 50 feet from wells, 5 ft from building foundations and appurtenances, and out of right-of-ways and easements. *Existing septic tank is partially under existing deck. Unhook existing septic tank and backfill with flowable fill or reconfigure deck. Install a 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface). *Supply line will have to be rerun from new septic tank to reconfigured lines. Must be sleeved in DOT culvert pipe under driveway. *Existing system consists of 4 lines at 75 ft long each. Top 3 lines will lose approximately 15 ft each. Cut these lines off at least 10 ft from the barn and fence. Compact the area towards these appurtenances and set new drop boxes for distribution and serial feed the new bottom line. 'Install 46 linear feet of 25%reduction system, proposed 1 line on contour. *Final grade of septic area must shed surface water off and away from system. *All gutter drains must be routed away from the septic system. 11/15/2022 11:35