HomeMy WebLinkAboutAUTH-11-2022-183719.TIF t r
•
CATAwl3ACOl:NTI• Case# AIIl'II-11-2022-183719
N .t. , Public Health Department Subdivision
�1 Environmental!leak!'Division PINA 460604836595
PO Box 389.25 Government Drive,Newton,NC 28658 LOl'#
w
Site Address: 7883 VISTA VIEW DR, SHERRILLS FORD NC 28673
Name on Permit: LAKE NORMAN RENTALS LLC
Property Size: Acres 0.9
Directions: Sherrills Ford RD, Slanting Bridge to Vista View DR on Right
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 600 g.p.d.
Type of Facility: Primary Residence-
Basement? Yes Basement Plumbing? Yes Bedrooms: 5
Water Supply: Private Well Maximum Occupants: 10
Soil LTAR: 0.3 g.p.dift2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50%REDUCTION VERTICAL.-Alternating Dual Field Nitrification System
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Septic Tank: New Tank: 1,500 gal Second Septic Tank: 1,000 gal
Pump Tank 1.500 gal Grease Trap_gal
Dosing Volume 223 gal Pump Specs: 40.35 GPM @ 8.239 TDH
Pressure Head 2 ft Draw Down 7.75 in
Drainfield: Total Area: 1,641 sq ft Total Trench Length: 547 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 32 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 8 ft on center
Number of Drain Lines: 6 Trench Width: 2 ft
Distribution: LPP
Pre Treatment: NONE
Pump Required ***** Operator Required
Additional Specifications:
*This permit requires an Alternating Dual Field Nitrification system. Two separate nitrification fields are to be
installed with a diversion valve to allow alternation between the two fields.
*The diversion valve shall be constructed to resist 500 pounds crushing strength, structurally sound, and shall
be resistant to corrosion. Valves placed below ground level shall be provided with a valve box and suitable valve
stem so that they may be operated from the ground surface.
*A contract with a certified operator shall be required prior to issuance of Operation Permit for system. The
system should be switched between drain fields no more than once a year during the course of inspections.
*New Lines: 25'-6 blocks,33'-8 blocks, 60'-14 blocks, 50'-12 blocks,46'-11 blocks. Total blocks=62.
*Remove 2 panels per line in already installed drainfield.
*Please meet Catawba County EH on the job site before starting the installation. 828-320-3067.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Installed with Initial Soil LIAR: 0.3 g.p.d.lft2
:h l,,,,,i i 12/111.202 2 1345
e r
4., _• CATAWBA COUNTY cCasefl AU"fH-I1-2022183719
.t. Public Health Department Subdivision
Environmental Health Division PIN# 460604836595
PO Box 389,25 Government Drive.Newton,NC 28658 l,0'1'it
tw
Site Address: 7883 VISTA VIEW DR. SHERRILLS FORD NC 28673
Name on Permit: LAKE NORMAN RENTALS LLC
Property Size: Acres 0.9
Directions: Sherrills Ford RD, Slanting Bridge to Vista View DR on Right
Proposed System: 50%REDUCTION VERTICAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (I5A NCAC I 8A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification_Please notify Environmental Health of this change prior to system installation.
11/07/2022
Authorized State Agent Permit Issuance Date
11/7/2027
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehpennil 12/01/2022 13:45
Mffé? Ub d7 1 - 31(D) J
Catawba County Environmenta Health
, j)_._ i/63....711
(81) 75) (81)
(82)
I I ,
1 e ,yL%r^ n
1 1407883 •7889
��J t�, 3� •7895
f---- , 4 4; Y520
----•-►787-7-- / 01)-\
o � �6��
iii
en
Cri co
--\I-' :
s v.
•
'v 16 M
V
•
•
0 1
r l
i
i'.5,6
�0
1
L` 1
V O0\—1 gyp,
i
e
112.80 48.0 41 ,•.,:;• • =• •
^_' r
Parcel: 460604836595, 7883 VISTA VIEW DR 1 in=60ft
SHERRILLS FORD, 28673
This map/report product was prepared from the Catawba County,NC Geospatial Information Services. Catawba County has made substantial efforts
to ensure the accuracy of location and labeling information contained on this map or data on this report.Catawba County promotes and recommends
the independent verification of any data contained on this map/report product by the user.The County of Catawba,its employees,agents,and
personnel,disclaim,and shall not be held liable for any and all damages,loss or liability,whether direct,indirect or consequential which arises or may
arise from this map/report product or the use thereof by any person or entity.
Copyright 2021 Catawba County NC
11/07/2022
6(0c6
- I (Q4
25)
sO
�(s \ t
It
9406 h_ 3,C9 2,3 7 d005
x , v
(7 p yvi
_3, 7 5 l2chllvt
1 rn
Z G 5 / i,r X 5 `1 3, 3i
Sys