HomeMy WebLinkAboutAUTH-11-2022-183481.TIF %fie CATAWBA COUNTY Case# AUfI1-11-2022-183481
.'.II Public Health Department Subdivision
Q 'j Environmental Health Division
'K/1". ,.10.. PIN# 375307782570
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
Site Address: 2668 COMMUNITY RD, CLAREMONT NC 28610
Name on Permit: MARTIN GONZALEZ
Property Size: Acres 33.73
Directions: Hwy 16 heading to taylorville turn right onto shook turn left onto community rd first land on left
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LTAR: 0.25 g.p.dlft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50%REDUCTION HORIZONTAL
System Classification: IIIE-PPBPS GRAVITY DOSED SYSTEM
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 720 sq ft Total Trench Length: 240 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 22 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 8 ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: Distribution Box
Pre Treatment: NONE
Additional Specifications:
*Do not cut,drive,fill, or grade over septic or repair areas.
*Septic system must be 10 ft from property lines, 50 ft from wells and creek, 5 ft from building foundations and
appurtenances, and out of right-of-ways and easements.
*Install a 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface).
*Install 240 linear feet of horizontal PPBPS system, proposed 5 lines total.
*Laid out 6 lines in the field.
*System will utilize top 3 lines and these 3 lines will be split in half and be centerfed via 5 outlet distribution box.
*All lines will be 48 feet in length. All lines will have 11 panels/line for a total of 55 panels.
*Final grade of septic area must shed surface water off and away from system.
*All gutter drains must be routed away from the septic system.
*Well should be 5 ft from property lines; 25 ft from structures; 50 ft from septic systems; and out of right-of-ways
and easements.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation. or the suspension/revocation of existina permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.25 9•P•d.Ift2
d,pc,mil I1/07/2022 08:16
CATAWBA COUNTY Case# AUTH-11-2022-183481
t1,7 t�-, Public Health Department Subdivision
Environmental Health Division PIN# 375307782570
) PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
t 84 SM
Site Address: 2668 COMMUNITY RD, CLAREMONT NC 28610
Name on Permit: MARTIN GONZALEZ
Property Size: Acres 33.73
Directions: Hwy 16 heading to taylorville turn right onto shook turn left onto community rd first land on left
Proposed System: 50%REDUCTION HORIZONTAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
11/02/2022
Authorized State Agent Permit Issuance Date
7/28/2027
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
chpcnnit 11/07/2022 08:16
(P u 2BPk ID-zozl- S9rtS'
Catawba County Environmental Health ,ttt - If-zo.z— IP3Ylr1
r - R"'- 07-zo22-t76S3-/
.!
! !
.40 .el
r_. !
,..44.- t...nl
__ !
. I !
! ! I "_
..... •2680
!
! I
! NI yo' S'M-
oo"' 2y
! re a
0
— N
Sr Q� Cd-lac
I
2 fit. p ,O `ft, ti o
��r ° 4d, 3 . _ .. tip.
-� r r u`—� . h
,,,f I-
PP '
1
\ .TO'
Ng
/ I.
s'-',\
--,.. i
illowilippoimP., '. .....
Parcel: 375307782570, 2668 COMMUNITY RD . 1 in=60ft
CLAREMONT, 28610
This map/report product was prepared from the Catawba County,NC Geospatial Information Services. Catawba County has made substantial efforts
to ensure the accuracy of location and labeling information contained on this map or data on this report Catawba County promotes and recommends
the independent verification of any data contained on this mapreport product by the user.The County of Catawba,Its employees,agents,and
personnel,disclaim,and shall not be held liable for any and all damages,loss or liability,whether direct,indirect or consequential which apses or may
arise from this map/report product or the use thereof by any person or entity.
Copyright 2021 Catawba County NC
11/03/2022