Loading...
HomeMy WebLinkAboutRBPR-11-2022-42647.TIF catawba county public health December 16, 2022 Todd Galloway 5831 Janie Drive Unit B, Denver, NC 28037 Re: Application for Improvement Permit/Authorization to Construct for property site,4011 Reid Circle, Sherrills Ford, NC 28673 Health Department file number RBPR-11-2022-42647. Dear Mr. Galloway: The Catawba County Health Department, Environmental Health Division on 12/08/2022,evaluated the above referenced property at the site designated on the plat/site plan that accompanied your Authorization to Construct -Expansion application. According to your application the site is to serve a 3-bedroom home with a design wastewater flow of 360 gallons per day. The evaluation was done in accordance with the laws and rules governing wastewater systems in North Carolina General Statute 130A-333 including related statutes and Title 15A, Subchapter 18A,of the North Carolina Administrative Code, Rule.1900 and related rules. Based on the criteria set out in Title 15A,Subchapter 18A,of the North Carolina Administrative Code, Rule.1940 through .1948,the evaluation indicated that the site is UNSUITABLE for a sanitary system of sewage treatment and disposal. Therefore,we must deny your request for an improvement permit. A copy of the site evaluation is enclosed. The site is unsuitable based on the following: Unsuitable soil topography and/or landscape position (Rule.1940) Unsuitable soil characteristics(structure or clay mineralogy) (Rule.1941) X Unsuitable soil wetness condition(Rule .1942) X Unsuitable soil depth (Rule.1943) Presence of restrictive horizon (Rule .1944) X Insufficient space for septic system and repair area(Rule.1945) Unsuitable for meeting required(Rule.1950) Other(Rule.1946) These severe soil or site limitations could cause premature system failure,leading to the discharge of untreated sewage on the ground surface, into surface waters,directly to ground water or inside your structure. The site evaluation included consideration of possible site modifications, as well as use of modified, innovative, or alternative systems. However,the Health Department has determined that none of the above options will overcome the severe conditions on this site. A possible option might be a system designed to dispose of sewage to another area of suitable soil or off-site to additional property. catawbacountync.gov Environmental Health Cctcwbc County Government Center 25 Government Drive I PO Box 389 I Newton NC 28658 1828.465.8270 MAKING. LIVING. BETTER. Page 2 For the reasons set out above,the property is currently classified UNSUITABLE,and no Authorization to Construct- Relocation shall be issued for this site in accordance with Rule.1948(c). Note that a site classified as UNSUITABLE may be classified as PROVISIONALLY SUITABLE if written documentation is provided that meets the requirements of Rule.1948(d). A copy of this rule is enclosed. You may hire a consultant to assist you if you wish to try to develop a plan under which your site could be reclassified as PROVISIONALLY SUITABLE. You have a right to an informal review of this decision. You may request an informal review by the soil scientist or environmental health supervisor at the local health department. You may also request an informal review by the North Carolina Department of Health and Human Services regional soil scientist. A request for informal review must be made in writing to the local health department. You also have a right to a formal appeal of this decision. To pursue a formal appeal,you must file a petition for a contested case hearing with the Office of Administrative Hearings,6714 Mail Service Center, Raleigh, NC 27699- 6714. To get a copy of a petition form,you may write the Office of Administrative Hearings or call the office at (919)431-3000 or download it from the OAH web site at http://www.ncoah.com/forms.html . The petition for a contested case hearing must be filed in accordance with the provision of North Carolina General Statutes 130A-24 and 150E-23 and all other applicable provisions of Chapter 150B. N.C. General Statute 130A-335 (g) provides that your hearing would be held in the county where your property is located. Please note:If you wish to pursue a formal appeal,you must file the petition form with the Office of Administrative Hearings WITHIN 30 DAYS OF THE DATE OF THIS LETTER. The date of this letter is 12/16/2022. Meeting the 30 day deadline is critical to your formal appeal. If you file a petition for a contested case hearing with the Office of Administrative Hearings,you are required by law(N.C. General Statute 150E-23)to serve a copy of your petition on the Office of General Counsel, N.C. Department of Health and Human Services, 2001 Mail Service Center, Raleigh, N.C. 27699-2001. Do not serve the petition on your local health department. Sending a copy of your petition to the local health department will not satisfy the legal requirement in N.C. General Statute 150E-23 that you send a copy to the Office of General Counsel, N. C. Department of Health and Human Services. You may call or write the local health department if you need any additional information or assistance. Sincerely, 6dAivv, ''( _ ZJtJA._- James R Ross, REHS Environmental Health Specialist Enclosures: Site evaluation Rule .1942, .1943, .1945,and .1948 • • Catawba County Environmental Health t 1 D 0) 220.00 •4017 o• h 0 ' R� f 1 ( ,,..(5..) ' y! ,, �/S , i l,/( 21 / 2.--- C4` "‘ ' Y '',,,,6 CO re ).1") Q •3585 wJ 14.2 �� /.7 AL 32.5 m a 210.001,t 4cz ivie, v . +v REED CIR w1 by 8 s .4.< 6 `\ i ( 0 — 7 l-i r;& 2: iLvi, D� 04,77 er.l�reh.4 er . j Ov 1' .3962 5\./ e_41, so Parcel: 460702771455, 3585 BIG TIMBER DR -6) C- /] lin=50ft SHERRILLS FORD 28673 O'J 3 ` ! 9 -fit L gi 1 I _ Lr L1 &VA, fr ��G7/ TlJib rflap/reorl p\ duct was prepared from the Catawba County,NC Geospatial Information Services. Catawba County has made substantial efforts to ensure the accuracy of location and labeling information contained on this map or data on this report.Catawba County promotes and recommends the independent verification of any data contained on this map/report product by the user.The County of Catawba,its employees,agents,and personnel,disclaim,and shall not be held liable for any and all damages,loss or liability,whether direct,indirect or consequential which arises or may arise from this map/report prod ct or th e thereof by any person or entity. 3L\ Copyright 2021 Catawba County NC 3 /1 10/26/2022 Lt47 DEPARTMENT OF HEALTH AND I iUMAN SERVICES Sheet _of — DIVISION OF PUBLIC HEALTH,ENVIRONMENTAL HEALTH SECTION PROPERTY ID#: ON-SITE.WATER PROTECTION BRANCH COUNTY: Catawba_ SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM (Complete ill fields in full) OWNER: VI _ F !M I // _ APPLICATION DATE ADDRESS: DATE EVALUATED: 722 PROPOSED FACILITY: P O SED SIGN W(. 9): PROPERTY SIZE: LOCATION OF SITE: lowr tJ t_1'C; {'/Ct f �s r PROPERTY RECORDED: WATER SUPPLY: 0 Private U Public AWell U Spring El Other _ EVALUATION METHOD: ❑Auer Boring LI:t-rii Li Cut TYPE OF WASTEWATER: ifd'S-Wape U Industrial Process 0 Mixed dx yt il 1r 1�VI . t ,, 4 ry tip'I r 4 ' SOIL MOR HOLOG1' s OTHER . X ` x '; .- * (1�!4.l) 1 PROP`II E FACTORS j.' z' r. ; r,. , *4 r f .i. / " D s �,:. .1� ' i f, t PI�.O 1 t a r • a sLo % )1's! i r , '- 61 . t +.4• .134t .1941 '$Olt 1943' 1 , . .1144 t .) ISTRUCTUREJ CON CHI? WETN Sl SO�• !SAPRO RESTR i&I TAR .1 } ;_' rTEXTURE Mll4B Y COLOR- DEPTH CLASS BORIZ' Of-- 31 — Y El1 C 1A(4 J► kr.a • yo LL5 o3- r1IcL c (6444 2 ,C OS jfl, l • 0-)3 C- lI ll 3 jj-LillR ' k/� 1 Pi-1-1- 05 C.')-1 G FIT ,71 -39 ,5d 145,K iti-- 70.4zR ,...... Z-(5 4 3`i37G- s1 13 DESCRIPTION INITIAL SYSTEM REPAIR SYSTEM OTHER FACTORS(.1946):* _ SITE CLASSIFICATION(.1948):__ ___ IA tf Available Space(.1945) 1 System'fype(s) EVALUATED I3Y: �)L" Y��"1! L(� LI __ OTHER(S)PRESENT: Site LIAR COMMENTS: Updated February 2014 -- — — DEPARTMENT OF HEALTH AND HUMAN SERVICES Sheet__of DIVISION OF PUBLIC HEALTH,ENVIRONMENTAL HEALTH SECTION PROPERTY ID ii: ON-SHE WATER PROTECTION BRANCH COUNTY: Catawba SOEUSITE EVALUATION for ON-SITE WASTEWATER SYSTEM (Complete all fields in full) f OWNER: 'C'" en j Ti _ APPLICATION DATE ADDRESS: .111, DATE EVALUATED: - PROPOSED ACILITY: jj R(..: 0 D DES;ON LOW .1949): PROPERTY SIZE: -4271-41r79C62`-.4 LOCATION OF SITE: , i C .4 -, h i _—1. . .e. ,-, , i,c PROPERTY RECORDED: WATER SUPPLY: 0 Private U Public 11 C!Spring Cl Other EVALUATION METHOD: D Auger Boring S.144 0 Cut TYPE OF WASTEWATER: '114-Sewage 1.3 Industrial Process 0 Mixed 5: "t * ! ' '.•:', ...t...6..,l..e.ri;;- t.'z. ):, -...71,1.7* ;•°1,;.:,:.:v.l-i..'.t-'„,';'‘. .:'1.-:-, -':.: '.'.,1...:3. ' 010K9woucGY1: ;, OTHER(ini) PRO FACTORS e , ,. .i'41•,.. tI ,,„.,... --- .... ''SLOPE ..: 214);;; ' ' .144i: . ' . .1 9itLi-'NiiUR: IN : .,: .ikt, ...1744 -wY,..o, 0,. "intuartiRri 0.014 ::',11kiw wietigstIA ••:,*".SOIL 3 „ikiitui Rxgrte,,, t&i?tAte''..4 :IA ..., 7701*''' : '.. . -,04:9,0,':k,:,00f6.'4; PF.17% '4":5 :6i19*: '" mit ( -4/2/ F,' i J i -1-51 2l5K -.cr 51 Or6oetA- / / 1-11-0 1 2 I , , • 3 • 4 •DESCRIPTION INITIAL SYSTEM REPAIR SYSTEM OTHER FACTORS(.1946): 1/6 SITE CLASSIFICATION(.194 8): Available Space(.1945) LA .. _ EVALUATED BY: System Type(s) OTHER(S)PRESEN. V12_, \L /O. _da_k_4-41:!'d— Site LTAR . COMMENTS: -- _. ...... Updated February2014 1SA NCAC 18A.1942 SOIL WETNESS CONDITIONS (a)Soil wetness conditions caused by seasonal high-water table,perched water table,tidal water,seasonally saturated soil or by lateral water movement shall be determined by field evaluation for soil wetness colors and field observations, and may be assessed by well monitoring,computer modeling,or a combination of monitoring and modeling as required by this Rule.All sites shall be evaluated by an Authorized Agent of the Department using Basic Field Evaluation Procedures pursuant to Paragraph(b)of this Rule. (b)Basic Field Evaluation Procedures: (1)A soil wetness condition shall be determined by the indication of colors of chroma 2 or less(Munsell Color Charts)at>2%of soil volume in mottles or matrix of a horizon or horizon subdivision. However,colors of chroma 2 or less which are relic from minerals of the parent material shall not be considered indicative of a soil wetness condition. (2)A Soil wetness condition shall also be determined by the periodic direct observation or indication of saturated soils or a perched water table,or lateral water movement flowing into a bore hole, monitoring well,or open excavation above a less permeable horizon or horizon subdivision,that may occur without the presence of colors of chroma 2 or less. A soil wetness condition caused by saturated soils or a perched water table shall be confirmed to extend for at least three consecutive days.The shallowest depth to soil wetness condition determined by Subparagraph(b)(1)or(b)(2) of this Rule shall take precedence. (c)Site Suitability as to Soil Wetness:Initial suitability of the site as to soil wetness shall be determined based upon the findings of the Basic Field Evaluation Procedures made pursuant to Paragraph(b)of this Rule. Sites where soil wetness conditions are greater than 48 inches below the naturally occurring soil surface shall be considered SUITABLE with respect to soil wetness. Sites where soil wetness conditions are between 36 and 48 inches below the naturally occurring soil surface shall be considered PROVISIONALLY SUITABLE with respect to soil wetness.Sites where soil wetness conditions are less than 36 inches below the naturally occurring soil surface shall be considered UNSUITABLE with respect to soil wetness. Sites where a soil wetness condition is determined based upon the observation or indication of lateral water movement within 4R inches of the naturally occurring soil surface shall be considered UNSUITABLE,except when such water can be intercepted in accordance with I5A NCAC IRA .1956(4). (d)Alternative Procedures for Soil Wetness Determination:The Owner or the Owner's Legal Representative (Applicant)shall have the opportunity to submit documentation that the soil wetness condition and resultant site classification be alternately determined and reclassified by direct monitoring,computer modeling,or a combination of monitoring and modeling,in accordance with a Direct Monitoring Procedure,Monitoring and Modeling Procedure, or Modeling Procedure made pursuant to Paragraphs(e),(f),or(g)of this Rule.This determination shall take precedence over the determination made pursuant to the Basic Field Evaluation Procedures [Paragraph(b)of this Rule],when the conditions of Paragraphs(e),(f),or(g)of this Rule are met.Determination by one of these Monitoring or Modeling procedures shall also be required when: (1)the Owner proposes to use a wastewater system requiring a deeper depth to a soil wetness condition than the depth determined by the Basic Field Evaluation Procedures pursuant to Paragraph(b)of this Rule;or (2)the Owner proposes to use sites with Group III or IV soil within 36 inches of the surface and where drainage modifications arc proposed to be made, including the installation of subsurface drain tile, open drainage ditches,or surface landscape modifications,or on such sites when fill is proposed to be used in conjunction with existing or proposed drainage modifications. Final determination of soil wetness condition for these sites shall be made pursuant to the Modeling Procedure in Paragraph (g)of this Rule (e)Direct Monitoring Procedure. Soil wetness conditions may be determined by direct observation of the water surface in wells during periods of typically high water elevations utilizing the following monitoring procedures and interpretation method. (1)The applicant shall notify the local health department of the intent to monitor water surface elevations by submitting a proposal that includes a site plan,well and soil profile at each monitoring location,and a monitoring plan no later than 30 days prior to the monitoring period. An applicant other than the property owner shall have written authorization from the owner to be the owner's legal representative. Soil wetness and rainfall monitoring shall be conducted under the responsible charge of a third-party consultant or by the property owner or the owner's agent.A third party consultant is qualified when licensed or registered in accordance with G.S.89C(Engineers),G.S. 89E(Geologists),G.S. 89F(Soil Scientists),or G.S.90A Article 4(Registered Sanitarians),if required.The Owner shall submit the name(s)of the consultant(s)performing any monitoring on their behalf to the local health department. (2)The applicant shall submit a site plan showing proposed sites for wastewater system,shall provide the longitude and latitude of the site, location of monitoring wells,and all drainage features that may influence the soil wetness conditions,and specify any proposed fill and drainage modifications. (3)The applicant shall submit a monitoring plan indicating the proposed number,installation depth, screening depth,soil and well profile,materials and installation procedures for each monitoring well,and proposed method of analysis.A minimum of three water level monitoring wells shall be installed for water surface observation at each site.Additional wells shall be required for sites handling systems with a design flow greater than 600 gallons per day(minimum of one additional well per 600 gallons per day increment). (4)The local health department shall be given the opportunity to conduct a site visit and verify the appropriateness of the proposed plan. Well locations shall include portions of the initial and replacement drainfield site(s)containing the most limiting soiUsite conditions. Prior to installation of the wells the local health department shall approve the plan.If the plan is disapproved,the local health department shall include specific changes necessary for approval of the monitoring plan. (5)Wells shall extend at least five feet below the natural soil surface,or existing soil surface for fill installed prior to July 1, 1977 meeting the requirements for consideration of a site with existing fill of G.S. 130A-341 and the rules adopted pursuant thereto.However,a well or wells which extend(s) down only 40 inches may be used if they provide a continuous record of the water table for at least half of the monitoring period,and one or more shallower wells may be required on sites where shallow lateral water movement or perched soil wetness conditions are anticipated. (6)Water surface in the monitoring wells shall be recorded at least daily from January 1 to April 30, taken at the same time during the day(plus or minus three hours).A rain(precipitation)gauge is required within one-half mile of the site. At least daily rainfall shall be recorded beginning no later than December 1 through April 30(the end of the well monitoring period). (7)Interpretation Method for Direct Monitoring Procedure:The following method of detennining depth to soil wetness condition from water surface observations in wells shall be used when the 60-day weighted rainfall index for the January through April monitoring period equals or exceeds the site's long-term(historic)60-day weighted rainfall index for January to April rainfall with a 30 percent recurrence frequency(wetter than the 9th driest year of 30,on average).The 60-day weighted rainfall index for the monitoring period and historic rainfall record shall be computed as: WRI60=0.5PD+PJ+PF+PM+0.5PA Where WRI60=60-day weighted rainfall index for January to April PD=Total December rainfall PJ=Total January rainfall PF=Total February rainfall PM=Total March rainfall PA=Total April rainfall The Department shall prepare contour maps for each county where this interpretation procedure is proposed.Contours shall be prepared following standard interpolation procedures using normalized data collected from all National Weather Service Stations,or equivalent, from which appropriate data are available,at least prior to February 1 of the monitoring season.Data from each station shall be normalized by fitting a 2-parameter gamma distribution to the 60-day weighted rainfall index computed for at least the most recent three decades of historic data,in accordance with procedures outlined in Chapter 18 of the National Engineering Handbook,NRCS, USDA. From this fitted distribution,the 60-day weighted rainfall index for January through April rainfall with a 30%,50%, 70%and 80%recurrence frequency shall be computed for each Station,to provide the raw data points from which the contour maps shall be prepared.From these maps,the site's 60-day weighted rainfall index for the January through April monitoring period shall be compared to the long-term (historic)January to April 60-day weighted rainfall index at different expected recurrence frequencies.The soil wetness condition shall be determined as the highest level that is continuously saturated for the number of consecutive days during the January through April monitoring period shown in the following table: Recurrence Frequency Range January to April 60-Day Weighted Rainfall Index Number of Consecutive Days of Continuous Saturation for Soil Wetness Condition 30%to 49.9%3 days or 72 hours 50%to 69.9%6 days or 144 hours 70%to 79.9%9 days or 216 hours 80%to 100% 14 days or 336 hours (8)If monitoring well data is collected during monitoring periods that span multiple years,the year which yields the highest(shallowest)soil wetness condition shall be applicable. (f)Monitoring and Modeling Procedure: A combination of monitoring and modeling may be used to determine a soil wetness condition utilizing the following monitoring procedures and interpretation method. (1)The procedures described for the Direct Monitoring Procedure in Subparagraphs(ex 1),(2),(3),(4), (5),and(6)of this Rule shall be used to monitor water surface elevation and precipitation for determining soil wetness conditions by a combination of direct observation and modeling,except that the rainfall gauge and each monitoring well shall use a recording device and a data file (DRAINMOD-compatible)shall be submitted with the report to the local health department(devices shall record rainfall at least hourly and well water level at least daily). (2)The ground water simulation model DRAINMOD shall be used to predict daily water levels over at least a 30 year historic time period after the model is calibrated using the water surface and rainfall observations made on-site during the monitoring period.The soil wetness condition shall be determined as the highest level predicted by the model to be saturated for a 14-day continuous period between January 1 and April 30 with a recurrence frequency of 30 percent(an average of at least 9 years in 30). (A)Weather input files,required to run the DRAINMOD,shall be developed from hourly rainfall gauge data taken within a half-mile of the site and from daily temperature and hourly or daily rainfall data collected over a minimum 30-year period from the closest available National Weather Service,or equivalent,measuring station to the site. DRAINMOD weather data files on file with the Department shall be made available upon request to the applicant or applicant's consultants.Daily maximum and minimum temperature data for the January 1 through April 30 monitoring period,plus for at least 30 days prior to this period,shall be obtained from the closest available weather station. (B)Soil and Site inputs for DRAINMOD,including a soils data file closest to the soil series identified,depths of soil horizons,estimated saturated hydraulic conductivity of each horizon,depth and spacing of drainage features and depression storage,shall be selected in accordance with procedures outlined in the DRAINMOD Users Guide,and guidance is also available in Reports 333 and 342 of the University of North Carolinas Water Resources Research Institute.DRAINMOD soils data files on file with the Department shall be made available upon request to the applicant or applicant's consultants. (C)Inputs shall be based upon site specific soil profile descriptions Soil and site input factors shall be adjusted during the model calibration process to achieve a best fit by least squares analysis of the daily observations over the whole monitoring period(mean absolute deviation between measured and predicted values no greater than eight inches),and to achieve the best possible match between the highest water table depth during the monitoring period(measured-vs-predicted)that is saturated for 14 consecutive days. (D)For sites intended to receive over 1500 gallons per day, the soil wetness determination using DRAINMOD shall take into consideration the impact of wastewater application on the projected water table surface. (E)The ground water simulation analysis shall be prepared and submitted to the local health department by individuals qualified to use DRAINMOD by training and experience and who are licensed or registered in North Carolina if required in G.S. 89C(Engineers), G.S. 89E(Geologists), and G.S.89F(Soil Scientists). The local health department or Owner may request a technical review by the Department prior to approval of the soil wetness condition determination. (g)Modeling Procedure: A soil wetness condition may be determined by application of DRAINMOD to predict daily water levels over at least a 30 year historic time period after all site-specific input parameters have been obtained,as outlined in the DRAINMOD Users Guide.This modeling procedure shall be used when a ground water lowering system is proposed for a site with Group III or IV soils within 36 inches of the naturally occurring soil surface.This procedure shall also be used to evaluate sites with Group III or IV soils within 36 inches of the naturally occurring soil surface,where the soil wetness condition was initially determined using a procedure described in Paragraphs(e) or(I)of this Rule and where drainage modifications are proposed or when fill is proposed to be used in conjunction with existing or proposed drainage modifications.The soil wetness condition shall be determined as the highest level predicted by the model to be saturated for a 14-day continuous period between January I and April 30 with a recurrence frequency of 30 percent(an average of at least 9 years in 30). (I)Weather input files,required to run DRAINMOD,shall consist of hourly rainfall and daily temperature data collected over the entire period of record but for at least a 30-year period from the closest available National Weather Service,or equivalent,measuring station to the site. DRAINMOD weather data files on file with the Department shall be made available upon request to the applicant or applicant's consultants. (2)Soil and Site inputs for DRAINMOD,including a soils data file closest to the soil series identified, depths of soil horizons,hydraulic conductivity of each horizon,depth and spacing of proposed drainage features and surface storage and drainage parameters,shall be selected in accordance with procedures outlined in the DRAINMOD User's Guide.DRAINMOD soils data files on file with the Department shall be made available upon request to the applicant or applicant's consultants. Inputs shall include: (A)Soil input file with the soil moisture characteristic curve and data for the soil profile that is closest to the described soil profile that is present on the site; (B)Soil horizon depths determined on site; (C)Site measured or proposed drain depth and spacing,and drain outlet elevation; (D)In-situ saturated hydraulic conductivity measurements for at least three representative locations on the site and at each location for at least three most representative soil horizons within five feet of the surface. Conductivity measurements shall be for one representative soil horizon at or above redoximorphic depletion features and two representative soil horizons at and below redoximorphic concentration features at each location on the site: (E)All other model parameters based upon the DRAINMOD User's Guide,or other accepted values consistent with the simulation model;and (F)A sensitivity analysis shall be conducted for the following model parameters: (i)Soil input files for at least two other most closely related soil profiles: (ii)Saturated hydraulic conductivity of each of horizons measured on-site; (iii)Drain depth and spacing;and (iv)Surface storage and depth of surface flow inputs. The sensitivity analysis shall be used to evaluate the range of soil and site characteristics for choosing input parameters related to the soil profiles,hydraulic conductivity input values based upon the range of hydraulic conductivity values measured on the site,and inputs for surface and subsurface drainage features based upon the range of possible elevations and distances that occur or may occur after installation of improvements.The sensitivity analysis shall establish which parameters are most critical for determination of the depth to soil wetness condition.Conservative values for the most critical parameters shall be used in applying the model to the site. (3)For sites designed to receive over 600 gallons per day,the soil wetness determination using DRAINMOD shall take into consideration the impact of wastewater application on the projected water table surface. (4)The ground water simulation analysis shall be prepared and submitted to the local health department by individuals qualified to use DRAINMOD by training and experience and who arc licensed or registered in North Carolina if required in G.S.89C(Engineers),G.S. 89E(Geologists),and G.S. 89F(Soil Scientists).The local health department shall submit the ground water simulation analysis to the Department for technical review prior to approval of the soil wetness condition determination. (h)A report of the investigations made for the Direct Monitoring Procedure,Monitoring and Modeling Procedure or Modeling Procedure pursuant to Paragraphs(e),(f),or(g)of this Rule shall be prepared prior to approval of the soil wetness condition determination.Reports prepared by a licensed or registered professional shall bear the professional seal of the person(s)whom conducted the investigation(Engineer,Geologist,Soil Scientist or Registered Sanitarian). A request for technical review of the report by the Department shall include digital copies of monitoring data and digital copies of model inputs,output data,and graphic results,as applicable. (j)Where the site is UNSUITABLE with respect to soil wetness conditions,it may be reclassified PROVISIONALLY SUITABLE if a modified,alternative or innovative system can be installed in accordance with 15A NCAC 18A.1956, .1957,or.1969. History Note:Authority G.5'. 130A-335(e): Eff.July 1, 1982; Amended Eff.January 1, 1990; Temporary Amendment Eff June 24, 2003;April 17, 2002; Amended Eff. May 1, 2004. 15A NCAC 18A.1943 SOIL DEPTH (a) Soil depths to saprolite,rock,or parent material greater than 48 inches shall be considered SUITABLE as to soil depth. Soil depths to saprolite, rock, or parent material between 36 inches and 48 inches shall be considered PROVISIONALLY SUITABLE as to soil depth. Soil depths to saprolite,rock,or parent material less than 36 inches shall be classified UNSUITABLE as to soil depth. (b) Where the site is UNSUITABLE with respect to depth, it may be reclassified PROVISIONALLY SUITABLE after a special investigation indicates that a modified or alternative system can be installed in accordance with Rule .1956 or Rule .1957 of this Section. History Note: Authority G.S. 130A-335(e); Eff July 1, 1982; Amended Eff.August 1, 1988. 15A NCAC 18A.1945 AVAILABLE SPACE (a) Sites shall have sufficient available space to permit the installation and proper functioning of ground absorption sewage treatment and disposal systems,based upon the square footage of nitrification field required for the long-term acceptance rate determined in accordance with these Rules. (b) Sites shall have sufficient available space for a repair area separate from the area determined in Paragraph(a)of this Rule.The repair area shall be based upon the area of the nitrification field required to accommodate the installation of a replacement system as specified in Rule .1955, .1956, or .1957 of this Section. Prior to issuance of the initial Improvement Permit for a site, the local health department shall designate on the permit the original system layout, the repair area,and the type of replacement system. (c)The repair area requirement of Paragraph(b)of this Rule shall not apply to a lot or tract of land: (1) which is specifically described in a document on file with the local health department on July 1, 1982, or which is specifically described in a recorded deed or a recorded plat on January I, 1983;and (2) which is of insufficient size to satisfy the repair area requirement of Paragraph(b)of this Rule,as determined by the local health department;and (3) on which a ground absorption sewage treatment and disposal system with a design daily flow of: (A) no more than 480 gallons is to be installed;or (B) more than 480 gallons is to be installed if application for an improvement permit which meets the requirements of Rule .1937(c)of this Subchapter is received by the local health department on or before April 1, 1983. (d)Although a lot or tract of land is exempted under Paragraph(c)from the repair area requirement of Paragraph(b), the maximum feasible area,as determined by the local health department,shall be allocated for a repair area. History Note: Authority G.S. 130A-335(e)and(1); Eff.July 1, 1982; Amended Eff. February 1, 1992;July 1, 1983;January 1, 1983. 15A NCAC 18A.1948 SITE CLASSIFICATION (a) Sites classified as SUITABLE may be utilized for a ground absorption sewage treatment and disposal system consistent with these Rules. A suitable classification generally indicates soil and site conditions favorable for the operation of a ground absorption sewage treatment and disposal system or have slight limitations that are readily overcome by proper design and installation. (b)Sites classified as PROVISIONALLY SUITABLE may be utilized for a ground absorption sewage treatment and disposal system consistent with these Rules but have moderate limitations. Sites classified Provisionally Suitable require some modifications and careful planning, design, and installation in order for a ground absorption sewage treatment and disposal system to function satisfactorily. (c)Sites classified UNSUITABLE have severe limitations for the installation and use of a properly functioning ground absorption sewage treatment and disposal system. An improvement permit shall not be issued for a site which is classified as UNSUITABLE. However, where a site is UNSUITABLE, it may be reclassified PROVISIONALLY SUITABLE if a special investigation indicates that a modified or alternative system can be installed in accordance with Rules.1956 or.1957 of this Section. (d)A site classified as UNSUITABLE may be used for a ground absorption sewage treatment and disposal system specifically identified in Rules.1955,.1956,or.1957 of this Section or a system approved under Rule.1969 if written documentation,including engineering,hydrogeologic,geologic or soil studies,indicates to the local health department that the proposed system can be expected to function satisfactorily. Such sites shall be reclassified as PROVISIONALLY SUITABLE if the local health department determines that the substantiating data indicate that: (1) a ground absorption system can be installed so that the effluent will be non-pathogenic, noninfectious,non-toxic,and non-hazardous; (2) the effluent will not contaminate groundwater or surface water;and (3) the effluent will not be exposed on the ground surface or be discharged to surface waters where it could come in contact with people,animals,or vectors. The State shall review the substantiating data if requested by the local health department. History Note: Authority G.S. 130A-335(e); Eff.July 1, 1982; Amended Eff April 1, 1993;January 1, 1990. U.S. Postal Service " CERTIFIED MAIL° RECEIPT o Domestic Mail Only .-n For delivery information,visit our website at www.usps.com5. Certified Mail fglitIlle Lr) $ ru Extra Services&Fees(check box add fee as appropriate) 0 Return Receipt(hardcopy) $ r1 0 Return Receipt(electronic) $ Postmark O ❑Certified Mail Restricted Delivery $ ,• here Q ❑Adult Signature Required $ �j ❑Adult Signature Restricted Delivery$ Postage \ /0/ Ln $ • 9 - \o Er Total Postage and Fees -- V $ EHPR-11-2022-42647 rR Sent To Todd Galloway ru p Street and AySESV Wee(Drive UniiB City,Mate, NC 28037 PS Form 3800 A•ril 2015 PSN 7530-02-000-9047 See Reverse for Instructions Certified Mail service provides the following benefits: •A receipt(this portion of the Certified Mail label). for an electronic return receipt,see a retail •A unique identifier for your mailpiece. associate for assistance.To receive a duplicate •Electronic verification of delivery or attempted return receipt for no additional fee,present this delivery. USPS®-postmarked Certified Mail receipt to the •A record of delivery(Including the recipients retail associate. signature)that is retained by the Postal Service- -Restricted delivery service,which provides fora specified period. tr , rized specifiedagent.by name,or • >• 1s Important Reminders: RE I which requires the •You may purchase Certified Mall service with signee to be at least 21 years of age(not First-Class Mailo,First-Gass Package Servicee, available at retail). or Priority Mail®service. -Adult signature r stricted delivery service,which •Certified Mall service is not available for D L r, 9quVes .��� to be at least 21 years of age International mail. d Provii- r• very to the addressee specdted •Insurance coverage is notavailable for purchase by name,or to the addressee's authorized agent with Certified Mail service.However,the purchase (not available at retail). of Certified Mail service does not change the •To ensure that your Certified Mail receipt is insurance coverage automatically included with ailing,it should bear a certain Priority Mail items, E( (On �r! o u d like a postmark on •For an additional fee,and with a proper this Certified Mail receipt,please present your endorsement on the mailpiece,you may request Certified Mail item at a Post Office'"for the following services: postmarking.If you don't need a postmark on this -Return receipt service,which provides a record Certified Mail receipt,detach the barcoded portion of delivery(including the recipient's signature). of this label,affix it to the mailpiece,apply You can request a hardcopy return receipt or an appropriate postage,and deposit the mailpiece. electronic version.For a hardcopy return receipt, complete PS Form 3811,Domestic Return Receipt;attach PS Form 3811 to your mailpiece; IMPORTANT.Save this receipt for your records. PS Form 3800,April 2015(Reverse)PSN 7530-02-000-9047 SENDER: COMPLEIE THIS SECTION COMPLETE THIS SECTION ON DELIVERY • Complete items 1,2,and 3. A. Signature -' ■ Print your name and address on the reverse x / rZ� )2 Agent so that we can return the card to you. /L� 1 / 0 Addressee • Attach this card to the back of the mailpiece, B. Received by(Printed Name) •ate of Delivery or on the front if space permits. 1. Article Addressed to: D. Is delivery address different from item 1? ❑Yes If YES,enter delivery address below: ❑No Todd Galloway 5831 Janie Drive Unit B a'. , gr, NC 28037 3. Service Type t]Priority Mail Express® llll I'll III I I ill I Ilil I Il III IIII I I I II I I Adult Signature D Adult Signature Certified Mail® Registered Mail" Restricted Delivery p Registered erad Mail Restrictec 9590 9402 7759 2152 4099 11 0 Certified Mail Restricted Delivery El Signature ConrirrnationTM Collect on Delivery ❑Signature Confirmation 2. Article Number(Transfer from service label) ID Collect on Delivery Restricted Delivery Restricted Delivery O insured Mail 7021 0950 0001 2506 6460 0 Insured Mall Restricted Delivery (over$500) PS Form 3811,July 2020 PSN 7530-02-000-9053 Domestic Return Receipt LISPS TRACKING# First-Class Mail Postage&Fees Paid LISPS y ? ? Permit No.G-10 9590 9402 7759 2152 4099 11 United States • Sender: Please print your name,address,and ZIP+4"in this box* Postal Service EH-10-2022-9786 RECEIVED James R Ross, REHS Catawba County Environmental Health PO Box 389 Newton, NC 28658 Environmenta8-i l catawba county public health AUTHORIZATION OF REFUND Date: 12/12/22 Case#: RBPR-11-2022-42647 Applicant: Todd Galloway Construction Refund Amount: 5450 Refund Reason: Application was denied. Refund AC and WELL fees. Authorizing Signature: 44//..1' fhv Received By Staff: CiattiL Date: )),I11t/)L catawbacountync.gov Environmental Health Ccicwha County Government Center 25 Government Drive ( PO Box 389 I Newton NC 28658 I 828.465 8270 MAKING. LIVING. BETTER. Catawba County, North Carolina - Disbursement Voucher Vendor No. — Date: 12/12/2022 Make Payment To: digmb.0 Voucher No(s) Todd Galloway Todd Galloway Construction 5831 Janie Dr, Unit B vQ r417 �' Denver, NC 28037 84'L ATTACHMENT Prepared by: Julia English Description Amount RBPR-11-2022-42647 was deniend. Refund AC and WELL fee $450.00 • • Sub-Total Food Tax Sales Tax Total $ 450.00 For Accounting Use Fund Cost Center Object Project Amount Only 110 580200 663000 Total The undersigned hereby certifies that the goods or services specified above have been received or performed. Payment has not been previously authorized and this expenditure is a proper charge to the appropriation indicated. The above charge is certified to you for payment. (SIGNATURE-APPROPRIATE OFFICIAL) $A CATAWBA COUNTY �' 100A SOUTHWEST BLVD NEWTON,P NORTH CAR 828.4658LINA 28658 RECEIPT V� 399 Monday,December 12,2022 I842 sM www.catawbacountync.gov PAYOR: Todd Galloway Construction Todd Galloway Construction(Galloway,Todd) PAYMENTS TRANSACTION NUMBER: TRC-53084297-12-12-2022 PAYMENT DATE: 12/12/2022 PAYMENT TYPE: DV INVOICE NUMBER ACCOUNT FEE NAME FEE AMOUNT 11-22-414138 110-580200-663000 Well Permit& Inspection Fee ($300.00) 11-22-414138 110-580200-663000 Authorization to Construct Fee(N (S150.00) ew/Expansion)Fee TOTAL PAYMENTS: ($450.00) RBPR-11-2022-42647 CASE TYPE: Residential Building Plan Review WORK CLASS: Building New SITE ADDRESS: 4011 REID CIR,SIIERRILLS FORD NC 28673 Applicant TODD GALLOWAY CONSTRUCTION,5831 JANIE DR UNIT B,DENVER NC 28037 B:7043081078 TGALLOWAYCONST@GMAIL.COM **NO PEOPLESOFT ACCOUNT ASSIGNED** Owner SESSOMS AVIS DAGENHART FAMILY TRUST,3575 BIG TIMBER DR,SHERRILLS FORD NC 28673 Contractor *TODD GALLOWAY CONSTRUCTION INC.,5851 BALSOM RIDGE RD UNIT B,DENVER NC 28037 B:7043081078C:7043081079 TGALLOWAYCONSTaGMAIL.COM receipt 12/12/2022 08:43 Page 1 of I