HomeMy WebLinkAboutAUTH-10-2022-182893.TIF w`IM*. CATAWBA COUNTY
(....
it.s+, Public Health Department
, ri Subdivision
R , i Environmental Health Division PINK 361903003962
PO Box 389,25 Government Drive,Newton,NC 21658 LOT"
Sit.Address: 3538 ZION CHURCH RD,HICKORY NC 28602
Name on Permit *OAKWOOD HOMES#712
Property Sim Acres 5.54
Directions: Left Old Conover Startown Rd,Left Startown RD,Right Hwy 10,Right Ziopn Church RD,End at 3528 Zion
Owner/Authorized Representative Acknowledgement of Permit Receipt
CrI certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
�/the property described above.
J(�° As the property owner or authorized representative,I have received the above referenced
1 permit(s)as requested in the application for service RBPR-08-2022-41940,by the following method(s):
_ Received in Person
4 Facsimile Transmittal(Return form with signature required)
Electronic Image Transmittal!E-mail (Return receipt required)
2 As the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900),
and/or Well Construction Standards(1 SA NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 10/24/2022
Owner/Authorized Representative Signature
-2 CIA-.
Date IU-'(.� -Z�
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of person sending permit)
Signature Date/Time 17/_)03
Method: Fax t/ Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt to hear from yosPtease ttake a few momentts no complete our customer service survey an
http://www.surveyrnonkey.com/s/EHCusttomerService
r71)e milutoSA,#s.&
'17,r
,,,„a„„, I0252022 16:17
�w• CATAWl3.A COE;NTv Case# Ati111-111-2022-182893
� .t. Public flcalthDepartment Subdivision
.� Environmental Health Division PIN# 361903003962
PO Box 389,25 Government Drive.Newton,NC 28658 LOT#
2 su
Site Address: 3538 ZION CHURCH RD, HICKORY NC 28602
Name on Permit: *OAKWOOD HOMES#712
Property Size: Acres 5.54
Directions: Left Old Conover Startown Rd, Left Startown RD, Right Hwy 10, Right Ziopn Church RD, End at 3528 Zion
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 480 g.p.d.
Type of Facility: Primary Residence-New House
Basement? No Basement Plumbing? No Bedrooms: 4
Water Supply: Private Well Maximum Occupants: 8
Soil LTAR: 0.275 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1.000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 1'320sq ft Total Trench Length: 440 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 16 in
Minimum Soil Cover: 8 in Minimum Trench Separation 9 ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Pump *May Be* Required
Additional Specifications:
*Do not drive, grade, cut or fill over any part of the initial or repair septic areas.
*All parts of the septic system area MUST remain 10 feet from property lines, and 5 feet from building structure
including decks or porches).
*Install new 1000 gal septic tank and 440 linear feet of 25% reduction product according to manufacture
specifications.
*Pump MAY BE REQUIRED if plumbing does not allow for gravity dispersal of effluent.
*4 additional inches of cover required.
*Reference Tree(RT)marked in field with green flags.
*DO NOT REMOVE REFERENCE TREE PRIOR TO SEPTIC INSTALLATION.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LIAR: .1375g,p.d.lft2
Proposed System: DRIP IRRIGATION
System Classification: VA-SAND FILTER PRETREATMENT
clycinin 10%28i2022 15:17