HomeMy WebLinkAboutAUTH-10-2022-182685.TIF •
49�T& CATAWBA COUNTY Case#
d+ ` Public Health Department Subdivision
3 q,-a t Environmental Health Division PIN# 269902699716
f;1:Y w
# PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 2
Site Address: 5202 DEER PINE DR,HICKORY NC 28602
Name on Permit: *LAUREN& LORENZO DIMAIO
Property Size: Acres 10
Directions: Right off of Pittstown Rd onto Sand Pit Rd. Right onto Deer Pine Dr.Lot at end of rd.
Owner/Authorized Representative Acknowledgement of Permit Receipt
LD I certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
the property described above.
i1.7 As the property owner or authorized representative,I have received the above referenced
permit(s)as requested in the application for service RBPR-07-2022-41751, by the following method(s):
Received in Person
Facsimile Transmittal (Return form with signature required)
V Electronic Image Transmittal/E-mail (Return receipt required)
bAs the property owner or authorized representative I have reviewed and understand the specific conditions
r` of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900),
and/or Well Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 10/20/2022
Owner/Authorized Representative Signature
-
..--r 2
Date 1p 1 4-1 i 27
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of'person sending permit)
Signature4g Date/Time /0 bili))
Method: Fax _ Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yoLPlease ttake a few momentts tto complette our custtomer service survey att
http://www.surveymonkey.com/s/EHCusttomerService
a dinnAi0 oil)bes l.am
chpenmi 10/20/2022 15:51
.4$' • CATAWBA COUNTY Case t, AUf11-10-2022-I82685
h t R•
,y Public Health Departmentimit Subdivision
1 `1 Environmental Health Division PIN;1 269902699716
.mil
PO Box 389,25 Government Drive.Newton,NC 28658 LO"hh 2
w
Site Address: 5202 DEER PINE DR, HICKORY NC 28602
Name on Permit: *LAUREN&LORENZO DIMAIO
Property Size: Acres 10
Directions: Right off of Pittstown Rd onto Sand Pit Rd. Right onto Deer Pine Dr. Lot at end of rd.
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 600 g.p.d.
Type of Facility: Prim Res/Acc Dwelling-3br house&2br pool house
Basement? No Basement Plumbing? No Bedrooms: 5
Water Supply: Private Well Maximum Occupants: 10
Soil LTAR: 0.3 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIG-OTHER NON-CONV TRENCH SYSTEMS
Septic Tank: New Tank: 1,500 gal
Pump Tank gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 1,500sq ft Total Trench Length: 500 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 4 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not cut,drive,fill,or grade over septic or repair areas.
*Septic system must be 10 ft from property lines, 100 feet from wells, 15 ft from swimming pools, 5 ft from
building foundations and appurtenances,and out of right-of-ways and easements.
*Install a 1,500 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface).
"Install 500 linear feet of 25%reduction system, proposed 4 lines total at 125 ft each, on contour.
*Final grade of septic area must shed surface water off and away from system.
*All gutter drains must be routed away from the septic system.
*Well should be 5 ft from property lines; 25 ft from houses, 100 ft from septic systems;and out of right-of-ways
and easements.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.275 g.p.d.lft2
Proposed System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
;!mrrr:ii 10/21/2022 14:38