HomeMy WebLinkAboutIMPV-10-2022-182289.TIF catawba county
public health
11/14/2022
D& E Properties LLC
7717 Windy Pine Circle
Denver, NC 28037
Subject: Notice of Intent to REVOKE the Improvement Permit for Storybrook, lot 11,Sherrills Ford
PIN 369701182992 Catawba County Permit IMPV-10-2022-182289
Dear Sir:
The Environmental Health Division of Catawba County Public Health intends to revoke your
Improvement Permit 30 days from the date of this notice.
If the permit is revoked,you must apply for a new Improvement Permit(IP) and meet the requirements
of the current laws and rules necessary to obtain a new IP.
You have a right to an informal review of this decision.You may request an informal review by the
environmental health supervisor at the local health department.You may also request an informal
review by the NC Department of Health and Human Services Regional Soil Scientist.A request for
informal review must be made in writing to the local health department.
You also have a right to a formal appeal of this decision. To pursue a formal appeal, you must file a
petition for a contested case hearing with the Office of Administrative Hearings 1711 New Hope Rd,
Raleigh, NC 27609. You may write the Office of Administrative Hearings, call the office at (984) 236-
1850 or get a copy of the petition form from the OAH web site at http://www.oah.nc.gov . The petition
for a contested case hearing must be filed in accordance with the provision of North Carolina General
Statutes 130A-24 and 150E-23 and all other applicable provisions of Chapter 150B. North Carolina
General Statute 130A-335 (g) provides that your hearing would be held in the county where your
property is located.
catawbacountync.gov
Environmental Health
Cctowbo County Government Center
25 Government Drive I PO Box 389 I Newton NC 28658 1828.465.8270
MAKING. LIVING. BETTER.
If you wish to pursue a formal appeal,you must file the petition form with the Office of Administrative
Hearings WITHIN 30 DAYS OF THE DATE OF THIS LETTER. The date of this letter is 11/14/2022.
Meeting the 30-day deadline is critical to your formal appeal.
If you file a petition for a contested case hearing with the Office of Administrative Hearings,you are
required by law(NC General Statute 150B-23) to serve a copy of your petition on the Office of General
Counsel, NC Department of Health and Human Services, 2001 Mail Service Center, Raleigh, NC 27699-
2001.
Respectfully
son Boyd, REH
Environmental Health Specialist
Catawba County Public Health
eti a CATAWBA COUNTY Case I MPV-10-2022-1 82289
ill GZ Public Health Department Subdivision STORYBROOK PH 1
d H Environmental Health Division PIN# 369701182992
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 11
/842 .
Site Address: STORYBROOK LN, SHERRILLS FORD NC 28673
Name on Permit *D&E PROPERTIES, LLC
Property Size: Acres 13.38
Directions: Hwy 16, left on Business 16, left on Mt Beulah, right on Little Mountain, 1/4 mile on the right
Improvement Permit
AN AUTHORIZATION TO CONSTRUCT MUST BE ISSUED PRIOR TO BUILDING PERMITS
THIS PERMIT IS NOT FOR SEPTIC INSTALLATION
Permit Category: New Septic
Wastewater Flow 360 g.p.d
Type of Facility: Primary Residence
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
INITIAL SYSTEM SPECIFICATIONS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
REPAIR SYSTEM SPECIFICATIONS
Repair System Required? Required
Proposed Wastewater System: DRIP IRRIGATION
System Classification: VA-SAND FILTER PRETREATMENT
Pump Required ***** Operator Required
Permit Conditions: Keep all parts of septic system and any future repair system minimum: 50'from any
individual well, 10'from property lines, 10'from home on crawl space, 10'from any water or
utility lines, 50'from creek.
Lines to be installed on contour.
Do not grade drive or fill over system or repair area.
Future repair will require drip irrigation and a proposal from a Professional Engineer.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper
drainage away from the septic system, including the direction of gutter flows or foundation drains,is not approved,and may result in failure to
approve the initial system installation,or the suspension/revocation of existing permits.
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Improvement Permit
is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Improvement Permit is not
affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and
Rules for Sewage Treatment and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the Environmental Health
Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
d— il Yi
10/13/2022
Authorized State Agent Permit Issuance Date
10/13/2027
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
wk., 10/17/2022 09:48
7}•�Y •
3
d ,
•
rY
A
1'
3R4
bo'
•
D'
IR•
tf D'
*L
Or•p 1Lapc. -- r
v, A
Goo Pi-2-
( b
•f
v+ •
C R'FF/t
}SR2- 4095L
M PY — — L L — 1FsZti9�3
Ito , 33 '
rj+iry Ln ,51,1,r,: lir F•rJ NIL
3 P k L., a+,.
I ' so ' * C 'x
Lot 1
Scanned with CamScanner
Department of Environment,Health,and Natural Resources Sheet:
Division of Environmental Health' Property ID:
On-site Wastewater Section Lot#:
SOIL/SITE EVALUATION File#:
for ON-SITE WASTEWATER SYSTEM AppID: EHPR-5-22-40992
Owner: D and E Properties(Keith Estes) Applicant:
Address: Storvbrook LN LOT 11 Date Evaluated: 9/28 and 9/30/22
Proposed Facility: 3 BR Home Design Flow(.1949) 360 Property Size:
Location of Site: Property Recorded:
Water Supply: pvt well [ ]Spring [ ]Other
Evaluation Method: pits by Keith Estes [ ]Cut
Type of Wastewater: X Sewage [ ]Industrial Process [ ]Mixed
P ��
R
o SOIL MORPHOLOGY b '
F .1941 PROFILE FACTORS
1 ,e 1940 .1942
I „'. _ Landscape, Horizon 1941 .1941 Soil .1943 .1956 .1944 Profilea Position/ Depth Structure/ Consistence Wetness! Sail Sapra Restr Class
l�i Slope?A , ,;.(]N) . :.. ;.Texture ;:Mineralogy ,,, ;;;,a. , ,p,psGplor,,, ...., , Depth(IN.) Class Horiz <AR _
1 LL 12-14% 0-8"A SU GR NS NP NEXP VFR
8-28"B C/w ABK SS SP SEXP FI 48 PS.25
28-48"B CL!w SBK SS SP SEXP FR
2 LL 14-16% 0-9"A SU GR NS NP NEXP VFR
9-24"B C/w ABK SS SP SEXP FR few mottles 10 YR 7/4 48" PS.25
24-48"B CU w SBK SS SP SEXP FR at 30-48"
3 LL14-16% 0-6"A SU GR NSNPNEXPVFR
6--22"B C/w ABK SS SP SEXP FR 10 YR 7/2 mottles at 32" 48" PS.1 DRIP
22-48"B CU w SBK SS SP SEXP FR
Description Initial System • Repair System Other Factors(.1946):
Available Space(.1945) PS PS Soil Evaluation By: Jason Boyd
i
System Type(s) III G 25%red *Pretreat to Drip Others Present: i
Site LIAR ..25 .1 Site Classification(.1948): PS
Site Evaluation By:
Others Present:
•
Sheet:
COMMENTS: FILE#:
Landscape Position Group Texture .1955 LTAR Structure
R-Ridge I S-Sand 1.2-0.8 SG-Single Grain
SS-Shoulder Slope LS-Loamy Sand M-Massive
LS-Linear Slope CR-Crumb
FS-Foot Slope II SL-Sandy Loam 0.8-0.6 GR-Granular
NS-Nose Slope L-Loam SBK-Subangular Blocky
HS-Head Slope ABK-Angular Blocky
CC-Concave Slope III SI-Silt 0.6-0.3 PL-Platy
CV-Convex Slope SICL-Silty Clay PR-Prismatic
T-Terrace Loam
FP-Flood Plain CL-Clay Loam
SCL-Sandy Clay
Loam
IV SC-Sandy Clay 0.4-0.1
SIC-Silty Clay
C-Clay
Consistence Consistence Mineralogy
Moist Wet SEXP-Slightly Expansive
VFR-Very Friable NS-Non-Sticky EXP-Expansive
FR-Friable SS-Slightly Sticky
FI-Firm S-Sticky
VFI-Very Firm VS-Very Sticky
EFI-Extremely Firm NP-Non-Plastic
SP-Slightly Plastic
P-Plastic
VP-Very Plastic
Sketch of Soil Evaluation Locations
SEE SITE PLAN