HomeMy WebLinkAboutAUTH-09-2022-181562.tif ..4,1y)4, w CATAWBA COUNTY
IT f Public Health Department Subdivision RAYNEBOW ACRES.
Environmental Health Division PIN# 364915549613
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 10
aftw ..
Site Address: 1586 NATHANIAL ST, NEWTON NC 28658
Name on Permit: JOANN ELLIS
Property Size: Acres 0.63
Directions: HWY 16 to Smyre Farm Rd to St James Ch Rd to Nathaniel St
Owner/Authorized Representative Acknowledgement of Permit Receipt
x7 g I certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
the property described above.
y3 As the property owner or authorized representative,I have received the above referenced
permit(s)as requested in the application for service RBPR-07-2022-41597,by the following method(s):
Received in Person
Facsimile Transmittal(Return form with signature required)
IElectronic Image Transmittal/E-mail (Return receipt required)
As the property owner or authorized representative I have reviewed and understand the specific conditions
o the permit issued, and further understand that all applicable regulatory requirements specified under the - .
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900), :
and/or Well Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date:09/30/2022
e,Owner/Authorized Representative Signature el/ 1";
Date A/0/27__
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means) -
Permit transmitted by (name of person sending permit)
Signature Date/Time .
Method: Fax Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yotPlease ttake a few momentts tto complette our custtomer service survey att
http://www.surveymonkey.com/s/EHCusttomerService
(2-r .
ettp mnt 09/30/2022 15:24
CATAWBA COUNTY Case# AUTH-09-2022-181562
E~ 2 Public Health Department Subdivision RAYNEBOW ACRES
Environmental Health Division PIN# 364915549613
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 10
Site Address: 1586 NATHANIAL ST, NEWTON NC 28658
Name on Permit: JOANN ELLIS
Property Size: Acres 0.63
Directions: HWY 16 to Smyre Farm Rd to St James Ch Rd to Nathaniel St
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 240 g.p.d.
Type of Facility: Primary Residence-New House
Basement? No Basement Plumbing? No Bedrooms: 2
Water Supply: Private Well Maximum Occupants: 4
Soil LTAR: 0.275 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONV TRENCH SYSTEMS
Septic Tank: New Tank: 1.000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 654 sq ft Total Trench Length: 218 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not drive,grade, cut or fill over any part of the initial or repair septic areas.
*Install new 1000 gal septic tank and 218 feet of 25%reduction product according to manufacturer
specifications.
*AII septic areas MUST remain 10 feet from property lines, 5 feet from building structure(including decks/porche
s), and 50 feet from neighboring well/well area.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions<<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 g.p.d./ft2
Proposed System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
ehpenttit 10/10/2022 12:59