HomeMy WebLinkAboutAUTH-09-2022-181446.TIF �_ CATAWBA COUNTY Case# AUTH-09-2022-18144fi
t� � Public Health Department Subdivision
Q Environmental Health Division PIN# 369904923630
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 2
Site Address: 6965 SHERRILLS FORD RD, SHERRILLS FORD NC 28673
Name on Permit: BRANDON&BECKY BLALOCK
Property Size: Acres 3.123
Directions: Right to stay on Sherrills Ford Rd that turns into Long Island Rd. 5th lot on right after Ted Ln.
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LTAR: .3 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1.000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 900 sq ft Total Trench Length: 300 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 30 in
Minimum Soil Cover: 12 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 4 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
Lot is on public water, no well required.
Keep all parts of septic system and any future repair system minimum: 100'from any well, 10'from property
lines, 10'from water and utility lines, 10'from home.
Lines to be installed on contour.
Do not grade,drive, or fill over system or repair area. Keep trench for water line on opposite side of driveway
from septic system to maintain 10'minimum setback.
Existing house on site will be converted to storage. No existing system on site.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: .3 9•P•d.lft2
Proposed System: 50%REDUCTION VERTICAL
System Classification: IIIE-PPBPS GRAVITY DOSED SYSTEM
chprmut !co 1/2022 14:14