Loading...
HomeMy WebLinkAboutAUTH-09-2022-181315.TIF �` ie. CATAWBA COUNTY 41416, y i tAi Public Health Department Subdivision 'i Environmental Health Division 'i.� PINS 367804628295 / Government Box 389,25 Drive,Newton,NC 28658 LOTS 68 E:Lie a Site Address: 3186 TIMBER RUN LN,MAIDEN NC 28650 Name on Permit: NEST HOMES LLC Property Size: Acres 0.75 Directions: S Hwy 16 Left Cayton Dr Left N Wynswept Dr Right Timber Run LN Owner/Authorized Representative Acknowledgement of Permit Receipt 1 h,1 I certify that I am the owner or authorized agent(owner's authorization required)representing the owner of the property described above. I 1t,i As the property owner or authorized representative,I have received the above referenced permit(s)as requested in the application for service RBPR-03-2022-40480,by the following method(s): Received in Person Facsimile Transmittal (Return form with signature required) 7 Electronic Image Transmittal/E-mail (Return receipt required) As the property owner or authorized representative I have reviewed and understand the specific conditions of the permit issued, and further understand that all applicable regulatory requirements specified under the North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900), and/or Well Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and the consttuction of the wastewater system and/or water supply well permitted. Permit Issue Date:09/28/2022 Owner/Authorized Representative Signature `s Date R i22.._ . ._ l Documentation of Permit(s)Transmittal (permit transmitted by electronic or other means) Permit transmitted by , (name of person snding permit) Signature (..iE Date/Time ?Io,1)) Method: Fax Email US Mail Other Owner's request to send by the above indicated method of transmittal in lieu of signature We wantt tto hear from yoaillease ttake a few momentts tto complette our custtomer service survey ett http://mvw.surveymonkey.com/s/EHCusttomerService A pvs/-orneshA .et Blip n"I' 09/29/2022 08:50 TV\\IV\ 4yi , CATAWBA COUNTY Case it AUTH-09-2022-181315 .1.iii ,. Public Health Department Subdivision Wynswept .� ) 4Envmental Heavision Subdivision PO Boxiron 3i39,25 GovernmentlthDi Dri367804628295 alit, w LOTi/ve,Newton,NC 28658 68 Site Address: 3186 TIMBER RUN LN, MAIDEN NC 28650 Name on Permit: *NEST HOMES LLC Property Size: Acres 0.75 Directions: S Hwy 16 Left Cayton Dr Left N Wynswept Dr Right Timber Run LN Authorization to Construct Permit Permit Category: New Septic Wastewater Flow: 480 g.p.d. Type of Facility: Primary Residence- Basement? No Basement Plumbing? No Bedrooms: 4 Water Supply: Private Well Maximum Occupants: 8 Soil LTAR: 0.3 g.p.d./ft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 25% REDUCTION System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP Septic Tank: New Tank: 1,000 gal Pump Tank 1,000 gal Grease Trap gal Dosing Volume 184 gal Pump Specs: 37.6 GPM @ 27.3 TDH Pressure Head 2 ft Draw Down 8.8 in Drainfield: Total Area: 1,206sq ft Total Trench Length: 402 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 32 in Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center Number of Drain Lines: 5 Trench Width: 3 ft Distribution: Pressure Manifold Pre Treatment: NONE Pump Required Additional Specifications: *Do not cut, drive,fill,or grade over septic or repair areas. *Issued off IMPV-08-2020-137564. *Septic system must be 10 ft from property lines, 50 feet from wells, 10 ft from water lines, 5 ft from building foundations and appurtenances, and out of right-of-ways and easements. *Install a 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface)and a 1,000 gallon pump tank with risers. *Pump tank will pump to a pressure manifold with 5 taps. *Install 402 linear feet of 25%reduction system, proposed 5 lines total at on contour. *Laid out 10 lines in the field. System will utilize lines 6 (green flags)78 ft, 7(white flags)78 ft, 8(blue flags)82 ft, 9 (orange flags)82 ft,and 10 (green flags)82 ft. *Pressure manifold will have 5 taps and all taps will be sch40 V2'. *Final grade of septic area must shed surface water off and away from system. *All gutter drains must be routed away from the septic system. *Well should be 5 ft from property lines;25 ft from structures;50 ft from septic systems; and out of right-of-ways and easements. ..h1+0rmi: 02/29/2022 16:12 4.4 ii�• CATAWBA COUNTY Case# AUTH-09-2022-1 8 1 3 1 5 • .j.It Public Health Department Subdivision Wynswept ,,, Environmental Health Division PIN# 367804628295 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 68 M Site Address: 3186 TIMBER RUN LN, MAIDEN NC 28650 Name on Permit: *NEST HOMES LLC Property Size: Acres 0.75 Directions: S Hwy 16 Left Cayton Dr Left N Wynswept Dr Right Timber Run LN See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains,is not approved,and may result in failure to approve the initial system installation,or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<< PROPOSED REPAIR Repair System Required? Required Soil LTAR: 0.3 9•P•d.1ft2 Proposed System: 25%REDUCTION System Classification: IIIB-SYSTEM MINGLE EFFLUENT PUMP Pump Required The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered.The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rules for Sewatte Treatment and Disposal Systems' (I5A NCAC I 8A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. , 7, s......-.,..._ /9 09/213/2022 Author iied State Agent Pennit Issuance Date 8/25/2025 Permit Expiration Date No grading or construction activity is allowed in areas designated far system and repair without approval of the Health Department. chpurmit 09/29/2022 16:12