HomeMy WebLinkAboutAUTH-08-2022-178578.TIF rC CATAWBA COUNTY Case 0 AUTH-08-2022-178578
•1.ri Public Health Department Subdivision
it Environmental Health Division PINK 376009169901
illi
;ri „
PO Box 389,25 Government Drive,Newton.NC 28658 LOIN
She Address: 3207 E NC 10 HWY,CLAREMONT NC 28810
Nam.on Permit: TERAMORE DEVELOPMENT
Property atze: Acres 1.87
Directions: 3207 E NC 10 Claremont
Owner/Authorized Representative Acknowledgement of Permit Receipt
X0 I certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
the property described above.
X /4 As the property owner or authorized representative,I have received the above referenced
permit(s)as requested in the application for service CBPR-06-2022-41352,by the following method(s):
Received in Person
Facsimile Transmittal(Return form with signature required)
2 Electronic Image Transmittal/E-mail (Return receipt required)
113fAs the property owner or authorized representative 1 have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 1SA.1900),
and/or Welt Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supp *ell permitted.
Permit Issue Date:08/25/2022 -- - ----, ____
Owner/Authorized Representative Signature
Date V "2-)0"1 /
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of person sending permit)
Signature Date/Time 0/3%3)
Method: Fax JEmail US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yoaPlease flake a few momentts tto complette our custtomer service survey art
http://www.surveymon key.com/s/E H CusttomerSe rvice
34( i C/C/a nd @ te c-mo1e. net
clpri.roi 08/23Q022 08 40
CATAWBA COUNTY Case# AUTH-08-2022-178578
j. 2 Public Health Department Subdivision
"4 Environmental Health Division PIN# 376009169901
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
/8 sw
Site Address: 3207 E NC 10 HWY, CLAREMONT NC 28610
Name on Permit: TERAMORE DEVELOPMENT
Property Size: Acres 1.87
Directions: 3207 E NC 10 Claremont
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 240 g.p.d.
Type of Facility: Business-DOLLAR GENERAL
Basement? No Basement Plumbing? No Bedrooms:
Water Supply: Public Water Maximum Occupants:
Soil LTAR: .225 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 2,000 gal
Pump Tank 2.000 gal Grease Trap_gal
Dosing Volume 123 gal Pump Specs: 24.5 GPM @ 34.85 TDH
Pressure Head 2 ft Draw Down 3.5 in
Drainfield: Total Area: 804 sq ft Total Trench Length: 268 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 18 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 2 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required ***** Operator Required
Additional Specifications:
*INSTALL ON CONTOUR
*PRESSURE MANIFOLD:
-2 SCH 40 3/4"TAPS
-GATE VALVE REQUIRED
-2"PRESSUREIZED SUPPLY LINE MUST BE 36" DEEP UNDER PARKING LOT MINIMUM
-SUPPLY LINE MUST BE 18 INCHES MINIMUM BELOW WATER LINE
-HIGH FLOW SPLASH PLATES OR SPLASH PADS REQUIRED PER MANUFACTURER
*INTERCEPTOR DRAIN REQUIRED 48" DEEP AS SHOWN ON SITE PLAN
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: .225 9•P•d.lft2
Proposed System: 50%REDUCTION HORIZONTAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
08/25/2022 10.48
�8: • CATAWBA COUNTY Case# AUTH-08-2022-178578
AR x
Public Health Department Subdivision
Q . 0 ,"�,
0Environmental Health Division PIN# 376009169901
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
/84 w
Site Address: 3207 E NC 10 HWY, CLAREMONT NC 28610
Name on Permit: TERAMORE DEVELOPMENT
Property Size: Acres 1.87
Directions: 3207 E NC 10 Claremont
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems'(15A NCAC 18A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
/ '_ ego 5,414S
08/25/2022
Authorized State Agent Permit Issuance Date
7/22/2027
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehpennit 08/25/2022 10:48