Loading...
HomeMy WebLinkAboutAUTH-08-2022-178578.TIF rC CATAWBA COUNTY Case 0 AUTH-08-2022-178578 •1.ri Public Health Department Subdivision it Environmental Health Division PINK 376009169901 illi ;ri „ PO Box 389,25 Government Drive,Newton.NC 28658 LOIN She Address: 3207 E NC 10 HWY,CLAREMONT NC 28810 Nam.on Permit: TERAMORE DEVELOPMENT Property atze: Acres 1.87 Directions: 3207 E NC 10 Claremont Owner/Authorized Representative Acknowledgement of Permit Receipt X0 I certify that I am the owner or authorized agent(owner's authorization required)representing the owner of the property described above. X /4 As the property owner or authorized representative,I have received the above referenced permit(s)as requested in the application for service CBPR-06-2022-41352,by the following method(s): Received in Person Facsimile Transmittal(Return form with signature required) 2 Electronic Image Transmittal/E-mail (Return receipt required) 113fAs the property owner or authorized representative 1 have reviewed and understand the specific conditions of the permit issued, and further understand that all applicable regulatory requirements specified under the North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 1SA.1900), and/or Welt Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and the construction of the wastewater system and/or water supp *ell permitted. Permit Issue Date:08/25/2022 -- - ----, ____ Owner/Authorized Representative Signature Date V "2-)0"1 / Documentation of Permit(s)Transmittal (permit transmitted by electronic or other means) Permit transmitted by (name of person sending permit) Signature Date/Time 0/3%3) Method: Fax JEmail US Mail Other Owner's request to send by the above indicated method of transmittal in lieu of signature We wantt tto hear from yoaPlease flake a few momentts tto complette our custtomer service survey art http://www.surveymon key.com/s/E H CusttomerSe rvice 34( i C/C/a nd @ te c-mo1e. net clpri.roi 08/23Q022 08 40 CATAWBA COUNTY Case# AUTH-08-2022-178578 j. 2 Public Health Department Subdivision "4 Environmental Health Division PIN# 376009169901 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# /8 sw Site Address: 3207 E NC 10 HWY, CLAREMONT NC 28610 Name on Permit: TERAMORE DEVELOPMENT Property Size: Acres 1.87 Directions: 3207 E NC 10 Claremont Authorization to Construct Permit Permit Category: New Septic Wastewater Flow: 240 g.p.d. Type of Facility: Business-DOLLAR GENERAL Basement? No Basement Plumbing? No Bedrooms: Water Supply: Public Water Maximum Occupants: Soil LTAR: .225 g.p.d./ft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 25% REDUCTION System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP Septic Tank: New Tank: 2,000 gal Pump Tank 2.000 gal Grease Trap_gal Dosing Volume 123 gal Pump Specs: 24.5 GPM @ 34.85 TDH Pressure Head 2 ft Draw Down 3.5 in Drainfield: Total Area: 804 sq ft Total Trench Length: 268 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 18 in Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center Number of Drain Lines: 2 Trench Width: 3 ft Distribution: Pressure Manifold Pre Treatment: NONE Pump Required ***** Operator Required Additional Specifications: *INSTALL ON CONTOUR *PRESSURE MANIFOLD: -2 SCH 40 3/4"TAPS -GATE VALVE REQUIRED -2"PRESSUREIZED SUPPLY LINE MUST BE 36" DEEP UNDER PARKING LOT MINIMUM -SUPPLY LINE MUST BE 18 INCHES MINIMUM BELOW WATER LINE -HIGH FLOW SPLASH PLATES OR SPLASH PADS REQUIRED PER MANUFACTURER *INTERCEPTOR DRAIN REQUIRED 48" DEEP AS SHOWN ON SITE PLAN See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Required Soil LTAR: .225 9•P•d.lft2 Proposed System: 50%REDUCTION HORIZONTAL System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION Pump Required ***** Operator Required 08/25/2022 10.48 �8: • CATAWBA COUNTY Case# AUTH-08-2022-178578 AR x Public Health Department Subdivision Q . 0 ,"�, 0Environmental Health Division PIN# 376009169901 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# /84 w Site Address: 3207 E NC 10 HWY, CLAREMONT NC 28610 Name on Permit: TERAMORE DEVELOPMENT Property Size: Acres 1.87 Directions: 3207 E NC 10 Claremont The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems'(15A NCAC 18A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. / '_ ego 5,414S 08/25/2022 Authorized State Agent Permit Issuance Date 7/22/2027 Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department. ehpennit 08/25/2022 10:48