HomeMy WebLinkAboutAUTH-08-2022-178296.TIF r ,
.44y,: • CATAWBA COUNTY Case# AUTH-08-2022-178296
E.:, t y. Public Health Department Subdivision FAIRWAY ACRES
. (.) ,,s, Environmental Health Division PIN# 372017015616
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 4
at 'U
Site Address: 2947 QUAIL DR, NEWTON NC 28658
Name on Permit: MARCOS HERRERA BARRAGAN
Property Size: Acres 0.99
Directions: Startown Rd, left onto Sandy Ford Rd, left onto Chestnut Dr, right onto Roeswood Ln, left onto Fairway Dr,
right onto Quail Dr,property on the left
Owner/Authorized Representative Acknowledgement of Permit Receipt
I certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
the property described above.
)6
_ As the property owner or authorized representative, I have received the above referenced
permit(s)as requested in the application for service EHPR-08-2022-41931,by the following method(s):
Received in Person
Facsimile Transmittal (Return form with signature required)
.7- Electronic Image Transmittal/E-mail (Return receipt required)
vAs the property owner or authorized representative I have reviewed and understand the specific conditions
r of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18A.1900),
and/or Well Construction Standards(15A NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 08/22/2022
Owner/Authorized Representative Signature
Date
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of person sending permit)
Signature 4 - Date/Time S ID it/72.,
Method: Fax y Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yo,Please ttake a few momentts tto complette our custtomer service survey att
http://www.surveymonkey.com/s/EHCusttomerService
5.-AI .c6 det.c r I s fi Rd.€Oki tic ti.OVA
I( . 19'
k;hpemtit 08/22/2022 10:53
�i • CAIAWBA COI \TV Case U AUTI I-08-2022-178296
Ili ,.4 Public Health Department Subdivision FAIRWAY ACRES
• '"mil,.•` iinvironmental Ilealth Division PIN# 372017015616
illikzt PO Box 389,25 Government Drive,Nev.lon,NC 28658 Lol'# 4
w
Site Address: 2947 QUAIL DR, NEWTON NC 28658
Name on Permit: MARCOS HERRERA BARRAGAN
Property Size: Acres 0.99
Directions: Startown Rd, left onto Sandy Ford Rd, left onto Chestnut Dr, right onto Roeswood Ln, left onto Fairway Dr,
right onto Quail Dr, property on the left
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 480 g.p.d.
Type of Facility: Primary Residence-SFD
Basement? Yes Basement Plumbing? No Bedrooms: 4
Water Supply: Private Well Maximum Occupants: 8
Soil LTAR: .3 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50%REDUCTION HORIZONTAL
System Classification: IIIE-PPBPS GRAVITY DOSED SYSTEM
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 804 sq ft Total Trench Length: 268 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 24 in
Minimum Soil Cover: 10 in Minimum Trench Separation: 5 ft on center
Number of Drain Lines: 4 Trench Width: 3 ft
Distribution: Distribution Box
Pre Treatment: NONE
Additional Specifications:
*NEW 1000GAL SEPTIC TANK
*SLEEVE ACROSS DRIVEWAYS WITH DOT APPROVED CULVERT
*HORIZONTAL PANEL BLOCK
*TRENCH DEPTHS:
-TRENCHES#1 AND#2, 24 INCHES DEEP LOW SIDE
-TRENCHES#3 AND#4, 14 INCHES DEEP LOW SIDE
-10 inches ADDITIONAL COVER NEEDED OVER TRENCHES 3&4
*TRENCHES ARE TO BE LEVEL AND FREE FROM ANY DEBRIS
*SAND IS TO BE CLEANED AND WASHED AND FREE FROM ANY DEBRIS
*NEW DISTRIBUTION BOX WAS INSTALLED AND INSPECTED ON EXISTING SEPTIC THE SAME TIME SOIL
EVALUATION WAS DONE
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions<<<<<
PROPOSED REPAIR
Repair System Required? Soil LTAR: g.p.d./ft2
Q•hpcmiu 08/24/21122 12.I 1