HomeMy WebLinkAboutAUTH-07-2022-176245.TIF (t )1
catawba county
public health
12/8/2022
Juan Pablo Herrera Rubiano
2021 Village View Cir
Apt 308
Belmont, NC 28012
Subject: Notice of Intent to REVOKE the Improvement Permit and Authorization to
Construct for 3151 Green Acres Ln PIN 376503114429
Catawba County Permits IMPV-07-2022-176240 and AUTH-07-2022-176245
Dear Mr. Herrera Rubiano:
The Environmental Health Division of Catawba County Public Health intends to revoke your
Improvement Permit and Authorization to Construct 30 days from the date of this notice.
If the permits are revoked,you must apply for a new Improvement Permit and Authorization to
Construct(IP/AC) and meet the requirements of the current laws and rules necessary to obtain a new
IP/AC.
You have a right to an informal review of this decision.You may request an informal review by the
environmental health supervisor at the local health department. You may also request an informal
review by the NC Department of Health and Human Services Regional Soil Scientist. A request for
informal review must be made in writing to the local health department.
You also have a right to a formal appeal of this decision. To pursue a formal appeal, you must file a
petition for a contested case hearing with the Office of Administrative Hearings 1711 New Hope Rd,
Raleigh, NC 27609. You may write the Office of Administrative Hearings, call the office at (984) 236-
1850 or get a copy of the petition form from the OAH web site at http://www.oah.nc.gov . The petition
for a contested case hearing must be filed in accordance with the provision of North Carolina General
Statutes 130A-24 and 150E-23 and all other applicable provisions of Chapter 150B. North Carolina
General Statute 130A-335 (g) provides that your hearing would be held in the county where your
property is located.
catawbacountync.gov
Environmental Health
Catawba County Government Center
25 Government Drive I PO Box 389 I Newton NC 28658 1828.465.8270
MAKING. LIVING. BETTER.
If you wish to pursue a formal appeal,you must file the petition form with the Office of Administrative
Hearings WITHIN 30 DAYS OF THE DATE OF THIS LETTER. The date of this letter is 12/8/2022. Meeting
the 30-day deadline is critical to your formal appeal.
If you file a petition for a contested case hearing with the Office of Administrative Hearings, you are
required by law(NC General Statute 150E-23) to serve a copy of your petition on the Office of General
Counsel, NC Department of Health and Human Services, 2001 Mail Service Center, Raleigh, NC 27699-
2001.
Respectfully,
can Evans, REHS
Environmental Health Specialist
Catawba County Public Health
CATANBA COUNTY
.i. , Public Health Department SAV1•is;..m EASTLAKE ESTATES PH 1-B
.st Env konncra i tteaith f), s:.m PS`: 376503114429
' PO Box)89.25 6overnmcnt l)rme.Newton.hC 2R65N t 01 4
Site Address: 3151 GREEN ACRES LN. CLAREMONT NC 28610
Name on Permit: JUAN HERRERA ROWAN()
Property Size: Acres 2.5
Directions: NC16-Right onto Oxford School Rd,Left onto Rest Home Rd,R;gnt onto Sheg Holier Rd.Right onto Green
Acres Ln Property on Right.
Owner/Authorized Representative Acknowledgement of Permit Receipt
��f\I certify that I am the ox+nor or authorized agent(owner's authorisation rcauircdi representing the Donor of
the property described above.
, 5 i As the property owner or authorised representative,I have received the above referenced
permit(s)as requested in the application for service RBPR-06-2022-41277. by the following method(s):
Received in Person
Facsimile Transmittal(Return form with signature required)
4 Electronic Image"Transmittal- E-mail (Return receipt required)
• the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(15A NCAC 18.A.1900),
and/or Well Construction Standards(I5A NCAC 2C.0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date:07r22/2022 —) I a
Owner/Authorized Representative Signatur
t _M,G"•l
7
Date ( I ?c:2. -
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted bs _...._-- (name of person
isending.perrn1)
Signature Dater Time t I))
_
Method: Fax .J Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yotPlease ttake a few momentts tto complette our custtomer service survey an
http://www.surveymonkey.com/s/EHCusttomerService
j herr e '&1'I`1I I eI tia Lie. ��.�n
U7 22 2022 I t?I
'-k71
44e CATAWBA COUNTY Case# AUTII-07-2022-176245
ti .t. ,/, Public Health Department Subdivision EASTLAKE ESTATES PH 1-B
Q —1 Environmental Health Division PIN 376503114429
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 4
Site Address: 3151 GREEN ACRES LN, CLAREMONT NC 28610
Name on Permit: JUAN HERRERA RUBIANO
Property Size: Acres 2.5
Directions: NC16-Right onto Oxford School Rd, Left onto Rest Home Rd, Right onto Shell Hollar Rd, Right onto Green
Acres Ln. Property on Right.
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-SFD
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LTAR: .3 g.p.d.Jft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1.000 gal
Pump Tank 1.000 gal Grease Trap_gal
Dosing Volume 137 gal Pump Specs: 23.33 GPM @ 28.47 TDH
Pressure Head 2 ft Draw Down 6.5 in
Drainfield: Total Area: 900 sq ft Total Trench Length: 300 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 20 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
*PUMP SYSTEM
*PRESSURE MANIFOLD:
-3 SCH 40 1/2"TAPS
-GATE VALVE REQUIRED
-SPLASH PADS OR HI-FLOW SPLASH PLATES AS REQUIRED BY(PRODUCT MANUFACTUAR
-2" PRESSUREIZED SUPPLY LINE
*RISERS REQUIRED ON SEPTIC AND PUMP TANKS
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions<<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: .3 9•P•d.Jft2
Proposed System: 25%REDUCTION
System Classification: IIIB-SYSTEM WJSINGLE EFFLUENT PUMP
Pump Required
.1,,r,nut 07/26/2022 14:52