Loading...
HomeMy WebLinkAboutOP-06-2022-174417.tif �y$' • CATAWBA COUNTY C'asetr OP-06-2022-174417 ELF -j. ,y, Public I[calth Department Subdivision CRESCENT LAND AND TIMBE . 6 Environmental[Icalth Division 2 SM IPIN/1460602563149 PO Box 350,25 Government Drive.Newton,NC 28GSH I OTI 127 Site Address: 7932 BANKHEAD RD, DENVER NC 28037 Name on Permit: MARK&PAM 4SM BUSINESS LLC Property Size: Acres 0.69 Directions: Burris Rd, right Bankhead to end Operation Permit Permit Category: Repairs Wastewater Flow: 360 g.p.d. Type of Facility: Primary Residence- Basement? No Basement Plumbing? No Bedrooms: 3 Water Supply: Private Well Maximum Occupants: 6 System Type: VA-SAND FILTER PRETREATMENT Description: 50%REDUCTION PPBPS VERTICAL System Code: PPBPS System Code Description: PPBPS Types V and VI systems expire in 5 years. Owner must contact Environmental Health 6 months prior to expiration for permit renewal. System Installation Comments: This septic system is sized for a maximum of 6 occupants. Please note it is critical not to hydraulically overload the septic system. Once you reach 80%of the total gallons per day you are overloading the system and continuously overloading the system will cause failure.Please use water saving practices and do not overload the house with guests. It is not recommended to use this septic system for weekly rentals. PERMIT CONDITIONS: 1.All maintenance, monitoring, &performance requirements shall be in accordance with 15A NCAC 18.1900, Rule.1961 2. Operation&Maintenance Specifics: Subsurface system operator required? Yes_X_ No This system has been installed in compliance with applicable NC General Statutes,Rules for Sewage Treatment and Disposal. Shane Cashion#4591 04/27/2022 System Installer Installation Date 41/PA fill 06/22/2022 Authorized State Agent Permit Issuance Date Form F 07 2X/2(122 15:17 S:\Survey\Propct.\7543 - 7932 Bonkh.od Rood\OWG\7545-EXHIBIT.dwg _ _1 • A • SITE AltI `Tii-01'112 .02- 45 S ,,.et.AR(k e S. EXHIBIT N + of e°^dead PURPOSES 0 P-- Ne 02 2 - 172-►y l7 =0 ! ENGINEERS 9,A- .78 • LLP 44. Compgro^\ ONLY :; .NO. F-1240/ ). 8 C 1 VICINIT1.4 Y MAP 4- 1J �` I� Z4z—e ;-1— S W Cr1 . tGt I I�j•I, �......t y,, j eeee, F. q (NOT TO SCALE) Of *iti c�r�7 0 40' 80' C Ou Q•t : Ov>yrl 1 L• J� G'T�:"N��� A t r�a1lons f y c 1, ,',�I f�l.c�S� 1 SCALE: 1' .. 40' eh-:A UOU3 8 Ot /►31j —u \. �^' ' `v� ll 7 0 Centaur Un. - LEGEND: (nod located I/12/2021) R/W ROCHT-OF-WAY / op Q FOUND CORNER Retaining / R�k� S ss3�� - \ LAKE NORMAN �• !aSEPTIC FLAG Wan c e , m sEPnc uD LAKE NORMAN / % Z. •' 1. 4j 13' At) Z / '�. Fie Pit N. e {, I/ `' �4 Pink/ / t. yCona.t• k_ ‘ \,,z,6 _ 11 /ter,/ WC/� ](.�e . I Uf�C/� / �I a Conc.to a PARCEL N' \ ^ A `�� ` t Poe it'wood 480802563149 r 1 L 1�e P� Pink/ ►• e 1+ F/',� S • LOT 127 0 cam, 1'�!{ 1. ` e l�C� Whit : • OVI t f n 0.694 ACRES u% \ -J'�"r . 1 V • \ . w Sand �r IN ,LCf_/`y1/ /l •is : e Volleyball G• 1 ' `� !�1 • �� N \ COU74 9� \ f� ! fi ta., 0j r , EJ , f7932 t."'"...J790 Co /1 / II.4to It `�11r (if B D -s, e� I Pi t, 7s� sos , ` I ` /L 111 �yti 9� s 1. . \ 33 FaWw 1.5• I e,4 • Iron Pip. „4 '' �2.0� T h Fond rs ReCar / PARCEL 3 Al / 460602562058 / ��? •hie fl ,� \ „/ LOT 126 SI Found JJJ���\ PLAT BOOK 16 / 3 `� • Reber \ PAGE 20 // ?9tr' cl Found / 15 Reber s'",.,.......,... /4(i /q-\* / rl / //I3/ / / \ / / \ // i / \ f/ / PARCEL 460602554904 '''''fFarad LOT 12B 115 Rector / PLAT BOOK 16 PARCEL f / PAGE 20 460602551976 LOT 125 + f PLAT BOOK 16 PAGE 20 '� IRS /t' M1 1 ( s•( n) IYYemv J 1 I " GENERAL NOTES Y I / 1. MEASUREMENTS ON THIS MAP ARE IN US SURVEY roar AM a DEGMALS TEREOF. 2. BOUNDARY 6 ORYARDEEDON BASED ON 0 BOOK 3607 PAGE �1 1665 AND PLAT BOOK 16 PACE 20 AS RECCRDETUIN THE _ CAT AWBA COUNTY REQSTER OF DEEDS.IN I' Q 3. POTS NOT LABELED'FOUND.OR'SET ARE COMPUTED rI 0 / POINTS ONLY. u.CORNERS FOUND OR SET ARE FLUSH KITH �1 THE ORg1HD UNLESS OTHERWISE NOTED. n' 4. MS PROPERTY MAY BE SUBJECT TO ANY EASEMENTS, PIEDMONT DESIGN ASSOCIATES, P.A. 125 East Plaza Drive I Suite#101 Engineering Mooresville, NC 28115 Surveying Phone: 704-664-7888 I Fax: 704-664-1778 Planning Email: dmunday@pdapa.com April 27, 2022 Catawba County Environmental Health Department PO Box 389 Newton, NC 28658 Attn: Mr. Robbie Phelps RE: TS-II LP PPBPS Subsurface Effluent Disposal System 7932 Bankhead Road, Catawba County, North Carolina Dear Mr. Phelps: ENGINEERS CERTIFICATION I, Donald L. Munday, as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe periodically the construction of the system repair of the referenced project, a TS-II low pressure PPBPS effluent disposal system; serving an existing 3 bedroom residence, located at 7932 Bankhead Road, Catawba County, NC, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. • Additionally, the existing precast septic tank was found to be, located less than 5 feet from existing deck foundation pier(s). A watertight test was performed on th'e existing precast septic tank, risers & lids and all were in satisfactory condition. There are no concerns with the current location of the existing tank in relation to the existing building structure. Sincerely, PIEDMONT DESIGN ASSOCIATES, P.A. ``owivaril Donald L. Munday, P.E. = SEAL N.C. Registration No. 17327 E 17327 Cc: Steve Barry, AQWA ', �' "" '" ' Zinnah Mannah, Owner ',AI i. 0„,\\� 05/02/2022 6/17/25,8:21 AM Mail-Robert Phelps-Outlook al Outlook FW: 7932 Bankhead Wastewater system From David DeCaron <ddecaron@pdapa.com> Date Tue 6/17/2025 8:10 AM To Robert Phelps <RPhelps@CatawbaCountyNC.gov> Warning: Unusual sender <ddecaron@pdapa.com> You don't usually receive emails from this address. Make sure you trust this sender before taking any actions. David DeCaron Piedmont Design Associates, P.A. 125 East Plaza Drive, Suite 101 Mooresville, NC 28115 Phone 704-664-7888 Email: ddecaron@pdapa.com NCBELS License No. C-1007 From:Tammy Riggan <aqwatammysanders@gmail.com> Sent: Monday,June 16, 2025 2:53 PM To: zmannah@goodlivingstr.com --- Jv✓h.r Cc: David DeCaron <ddecaron@pdapa.com>;Jonathan Handley<jhandley@aqwa.net>; Mike Barry <mbarry@aqwa.net> Subject: 7932 Bankhead Wastewater system Subject: Urgent: Potential Overload of Wastewater System Due to Excessive Occupancy Dear Sir/Madame, I hope this message finds you well. I am writing to inform you of a concern regarding the wastewater system at 7932 Bankhead. During a recent visit to collect the annual laboratory sample, we observed that the turbidity levels were elevated, indicating potential issues with the system's performance. Upon speaking with the current occupants who identified themselves as renters, we were informed that 22 individuals are residing in the home. This significantly exceeds the design capacity of the wastewater system, which was engineered and permitted for 6 occupants. According to North Carolina regulations, the design flow rate for wastewater systems is calculated based on the number of bedrooms and the expected occupancy . For instance, each bedroom is typically allocated 120 gallons per day, and occupancy exceeding two persons per bedroom requires adjustments to the design flow to accommodate the increased load. https://outlook.office.com/mail/inbox/id/AAkALgAAAAAAHYQD EapmEc2byACgAC%2FEWg0AwBznFwCnLOG7d9vc3ihLpgAAZjgYhwAA?nativeVersio... 1/2 6/17/25,8:21 AM Mail-Robert Phelps-Outlook The current occupancy level may lead to system overload, potentially causing failures in the drainfield and compromising the system's ability to meet permit treatment limits. I understand that circumstances may have changed, and I would appreciate any information regarding modifications to the property's design or permit that would justify the increased occupancy. If no such changes have occurred, I recommend reviewing the property's listing to ensure that the advertised occupancy aligns with the system's capacity and complies with local regulations. Please let me know if you require any further information or assistance in addressing this matter. I am committed to ensuring the proper functioning of the wastewater system and am available to discuss potential solutions. Thank you for your attention to this important issue. Tammy Riggan Operations Manager AQWA, Inc 1908 Baldree Road South Wilson, NC 27893 252-243-7693 hops://outlook,office.com/mail/inbox/id/AAkALgAAAAAAHYQDEapmEc2byACgAC%2FEWg0AwBznFwCn LOG7d9vc3ihLpgAAZjgYhwAA?nativeVersio... 2/2