Loading...
HomeMy WebLinkAboutIMPV-07-2022-175263.TIF Catawba county public health July 16,2024 Dana Overcash 110 Aqua Dr Mooresville, NC 28117 Subject: Notice of Intent to REVOKE the Improvement Permit and Authorization to Construct for 3543 Jefferson St,Sherrills Ford,NC 28673. PIN 369702873564 Catawba County Permits:IMPV-07-2022-175263 and AUTH-07-2022-175264 Dear Dana Overcash: The Environmental Health Division of Catawba County Public Health intends to revoke your Improvement Permit and Authorization to Construct 30 days from the date of this notice. If the permits are revoked,you must apply for a new Improvement Permit and Authorization to Construct(IP/AC)and meet the requirements of the current laws and rules necessary to obtain a new IP/AC. You have a right to an informal review of this decision.You may request an informal review by the environmental health supervisor at the local health department.You may also request an informal review by the NC Department of Health and Human Services Regional Soil Scientist.A request for informal review must be made in writing to the local health department. You also have a right to a formal appeal of this decision. To pursue a formal appeal,you must file a petition for a contested case hearing with the Office of Administrative Hearings 1711 New Hope Rd, Raleigh, NC 27609. You may write the Office of Administrative Hearings, call the office at(984) 236- 1850 or get a copy of the petition form from the OAH web site at http://www.oah.nc.gov. The petition for a contested case hearing must be filed in accordance with the provision of North Carolina General Statutes 130A-24 and 150E-23 and all other applicable provisions of Chapter 150B. North Carolina General Statute 130A-335 (g) provides that your hearing would be held in the county where your property is located. catawbacountync.gov Environmental Health Catawba County Government Center 25 Government Drive I PO Box 389 I Newton NC 28658 1828.465.8270 MAKING. LIVING. BETTER. If you wish to pursue a formal appeal,you must file the petition form with the Office of Administrative Hearings WITHIN 30 DAYS OF THE DATE OF THIS LETTER. The date of this letter is July 16,2024. Meeting the 30-day deadline is critical to your formal appeal. If you file a petition for a contested case hearing with the Office of Administrative Hearings,you are required by law (NC General Statute 150E-23)to serve a copy of your petition on the Office of General Counsel, NC Department of Health and Human Services,2001 Mail Service Center, Raleigh, NC 27699- 2001. spectf , an vans, REHS Environmental Health Specialist Catawba County Public Health • catawba county public health VOLUNTARY RELINQUISHMENT OF ADMINISTRATIVE APPEAL RIGHTS Date prepared: 6/12/2024 Owner(s): DANA QVI3RCASI'l Mailing Address: 110 AQUA DR MOORESVILLE,NC 28117 Property Jopatinn/site legal description: 3543 JI3PFERSON.Sf,SHlRR1LLS FORT)NC PIN: 3697132873564 Improvement Permit(It') IMI'V-07-2022-275263 Date issued 7/102SI22 Authorization to Constrict(AC) AUfll-07-2022-175264 Date Issued 7/82022 l DvIL.L Dit ( ,voluntarily relinquish my rights to pursue a fonnal appeal through the North (print full name) Carolina Office of Administrative Hearings pursuant to NC General Statute I30A-24 and I5013-23 and all other applicable provisions of Chapter 15013 for the above referenced pennit(s)(which includes the IPs and ACs)in order for the authorized agent/local health department to issue the applicable permit(new iP and/or AC)for the site. I understand by completing this form that the permit(s)for a 25%reduction (System description) will be revoked immediately by the authorized agent/local health department. I understand that the local health dcoarunem's revocation of a permit can be appealed to the North Carolina Office of Administrative Hearings within 30 days of the revocation pursuant to the North Carolina Administrative Procedure Act. I understand that in order liar the local health department to issue another IP and AC that the current II'and AC must be revoked. I understand that the local health department's revocation of:m IP or CA is not effective until 30 days from the revocation or,if the revocation is appealed,at the tint: that the Office of Administrative Hearings issues a final decision. 1 understand that by signing this Lorin and relinquishing my right t4 appeal the permit revocation at the Office of Administrative Hearings that the local health department's permit revocation will become effective immediately. i understand and agree that the revocation of a permit that takes effect immediately is in my best interest. I understand that by signing this form that I agree that I do not want to appeal the permit revocation. I understand that 1 urn not required to relinquish my appeal rights but that this is an option available to me so 1 do not have to wait 30 days for the revocation of the Hermit to take effect. Signature of Property Owner: A t'--U Cli"4"`c- Date Signed: 1— (.a NCDHHS/DPH/EHS/OSWP Revised May 2015 catawbacountync.gov Environmental Heaitn Colowbe County Government(enter 25 Government Drive I PO Box 389 I Newton NC 28658 1828.465.8210 MAKING. LIVING. BETTER. r CArAw8A COUNTY tIlLPublic HealthfkplcWnent SubJn coon "," Itt:nvironroemal Health Division F'I Na 369702873564 0 PO Box 389,25 Government tkrve.Newton,NC' 28655 t.1 f to Site Address: 3543 JEFFERSON ST,SHERRILLS FORD NC 28673 Name on Permit: TIMOTHY COLUNS Property Size: Ades 0.94 Directions: NC 16,Left Buffalo Shoals RD.Right onto UM Mountain RD,Letat on Little Mountain RD, Left onto Jefferson ST ,(�/� Owner/Authorized Repreentativc AcknowledgerncnI of 1'ermit Receipt 2[��i ccrtitj that I am the owner or authuriied agent(owner's authoriratitm required)representing the owner of fe the property described above. tAs the property owner or authorized representative.I have received the above referenced permit(s)as requested in the application for service RBPR-04-2022-407332,by the following method(s): Received in Person Facsimile Transmittal(Return farm with signature required) I Electronic Image Transmittal/E-mail (Return receipt required) 4�As the property owner or authorized representative I have reviewed and understand the specific conditions t/( of the permit issued, and further understand that all applicable regulatory requirements specified under the North Carolina Laws and Rules for Sewage Treatment and Disposal Systems(I5A NCAC 18A.1900), and/ur Well Construction Standards(15A NCAC 2C.0100). shall apply to the issuance of this permit and the construction of the wastewater system and/or water supply well permitted. Permit Issue Date:07/06/2022 Owner Authorized Representative Signature 'Mt Date 7?Z.9a _... Documentation of Permit(s)Transmittal (permit transmitted by electronic or other means) Permit transmitted by _ frame of person sending permit) Signature _-- E Daterlimc I i 1/4 Z Method: Fax f:mail �`t;s Hail Other Owner's request to send by the above indicated method of transmittal in lieu of signature We wentt tto hear from ywPlease ttake a few mornentts tto complette our custtomer service survey att http://www.surveymonkey.com/s/EHCusttomerService f,I in . I%•W°r310,4. 1'g r,n 07.l '4122 elk 11 �yib 4 . CATAWBA COUNTY Case# 1MPV-07-2022-175263 .I. ,y Public Health Department Subdivision Q ,111)"1 Environmental Health Division PIN# 111.9 l.0'[ 369702873564 PO Box 389,25 Government Drive,Newton,NC 28658 # !g4_ sr Site Address: 3543 JEFFERSON ST, SHERRILLS FORD NC 28673 Name on Permit: TIMOTHY COLLINS Property Size: Acres 0.94 Directions: NC 16 , Left Buffalo Shoals RD, Right onto Little Mountain RD, Lefet on Little Mountain RD, Left onto Jefferson ST Improvement Permit AN AUTHORIZATION TO CONSTRUCT MUST BE ISSUED PRIOR TO BUILDING PERMITS THIS PERMIT IS NOT FOR SEPTIC INSTALLATION Permit Category: New Septic Wastewater Flow 480 d 9.P. Type of Facility: Prim Res/Acc Dwelling Basement? No Basement Plumbing? No Bedrooms: 4 Water Supply: Private Well Maximum Occupants: 8 _ INITIAL SYSTEM SPECIFICATIONS Proposed Wastewater System: 25%REDUCTION System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS _ REPAIR SYSTEM SPECIFICATIONS Repair System Required? Required Proposed Wastewater System: 50%REDUCTION VERTICAL System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION Pump Required ***** Operator Required Permit Conditions: This permit issued pursuant to Section 11.(c)of SL 2018-114 using the signed and sealed LSS Evaluation attached here. Catawba County Environmental Health has not evaluated soils or site conditions for this property. Furthermore, CCEH has not field-verified soil descriptions submitted by the Licensed Soil Scientist. CCEH exclusively used the LSS evaluation and system design proposal to permit the septic system and future septic repair area. Catawba County Environmental Health is not responsible or liable for accuracy of soil descriptions or septic system design for this permit(s). Prior to CCEH's inspection of the system installation, all property corners must be surveyed, all property lines must be marked, and the 50 ft. lake setback, as applicable, must be surveyed. No deviation from the permit is permissible. If the system cannot be installed exactly as proposed by the LSS, maintaining all applicable setbacks under 15A NCAC 18A.1 900, the property owner is responsible for a LSS resubmittal under SL 2018-114 Section 11.(c ); new permit fees applicable. Do not drive,grade, cut,or fill over the septic system area/ septic repair area. Damage to the septic areas will result in permit revocation. **PLEASE NOTIFY Catawba County EHS of the scheduled septic installation date, at least one week in advance, so a pre-installation site visit can be made. Call 828-851-6547. *The septic drain lines must be flagged in by the system designer(LSS),before the septic installation can begin. *The water line must be at least 10 feet from any part of the septic system. :Iq,rmnd 07/13/2022 08:46 .41 • CATAWBA COUNTY Case# IMPV-07-2022-175263 i• tNIL ., Public Health Department Subdivision d '" Environmental Health Division PIN# 369702873564 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 8' 9, Site Address: 3543 JEFFERSON ST, SHERRILLS FORD NC 28673 Name on Permit: TIMOTHY COLLINS Property Size: Acres 0.94 Directions: NC 16, Left Buffalo Shoals RD, Right onto Little Mountain RD, Lefet on Little Mountain RD, Left onto Jefferson ST Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains,is not approved,and may result in failure to approve the initial system installation,or the suspension/revocation of existing permits. The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning,/Zoning and Building Inspections requirements are met. This Improvement Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Improvement Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina Yaws and Rules for Sewage Treatment and Disposal Systems' (I5A NCAC 18A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. ,f(........................ 1)0q4 Et,4,1 S 07/08/2022 Authorized State Agent Penult Issuance Date 7/8/2027 . Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department. rhprnnit 07/13/2022 0R:46 z. I Site Plan SFo s r r ,G- ,I1OkJU/ir ,,f e ) 5 ,13 j a..Y t-iL r s 0 /1 .S 5 h r 5 Y r ,q_ y r:=.,,,-, -`\ mPy - 7 _ 2Z _ I-? 5- 2..4, 3 �, It F.: �-t- - 7 Z 2 — 17 s i 6 z norm ..i ��r`'——'dw a°"'wow, • ' ' 4 j "'P.a....14;7..............:. • • ............ .4.4z,. I • 1 `�� .\..'.'..::; : :::::P.PBPS'(Vert:y;::: ::3824.sq tt =: s: 4ea agg. +` It/Me,. /a \4a�Kttee. 23%Rd❑ctlon ole ;Bedroo as - :6276zsq :: :�� � N*5... \\.\\ ''' -iocrOteebe rompovsd y Existing Septic `ST 81 ': System to be $CZ _ Q Q s Abandoned ,. 30 •.Ace.o ,hip k ``/ 36. 0 \ ex0poh • ' 0 Tii. Op lr �. g ....... — ilits, Wooden stake egond: (represents front • Soil Eveluatlon Locatl• Jefferson St right comer of 'Y MN house envelope) <all other values), eopey ...,. Ae Type Wood'take Is at BO'from front right %/I Initial Area prop.corner and 30' WM Repek Area from edge of rAit Potential Well Area right of way. t. '- ' S z wz h ,yz. s'�-: � yaaa4-a,`,.a ,.,at -x, ai,..f' ,': wM'u's u d . ;,. aS• :Cri i. ' _4-�r� ,, ' , a 4 BezTy 9 ", .s " :; .mpa .1i m ., w x #IL'4 " . .3, . 7', ' z ti ?t , . y�° , as �£ ..#.,.. Scanned with CamScanner K. Joe Johnson Soils and Development Consulting _ em _. . __ .. Monday,July 4,2022 Dana Overcash dowest529@yahoo.com Re: Licensed Soil Scientist property evaluation and wastewater system design/layout for Catawba County Parcel # 369702873564 located at 3543 Jefferson St. Sherrills Ford,NC. To Whom It May Concern, This Licensed Soil Scientist Evaluation is bein2 submitted pursuant to and meets the requirements ofSL 2018-114 Section'11.(c). A soil/site evaluation and wastewater system layout/design was performed on the above referenced 0.94 acre parcel to serve a 2 bedroom accessory dwelling+a 2-bedroom residence(maximum 8 occupants)with a total peak wastewater flow of 480 gallons per day. Work was conducted in accordance with the NC .1900 Rules for Sewage Treatment and Disposal Systems. Soil was evaluated on this property with a hand auger. Detailed soil horizon descriptions are included in this report with corresponding boring locations shown on the attached maps of the property. All borings were located using a Trimble Geo7X GPS unit. Existing wells were not observed within 50+feet of the approved septic system area. This report requests permitting installation of a gravity fed 25%reduction trench wastewater system with 440 linear feet of nitrification line to serve a 2 bedroom accessory dwelling+a 2 bedroom main residence per the attached design criteria and conditions spelled out in this report. Repair for this site is designated as PPBPS(Vertical)trench at 0.275 LTAR. This report is a total of 4 pages and must not be used or interpreted without the entire report available. I am pleased to be of service in this matter and can be reached at your convenience if additional services or information is needed to ensure the successful completion of this project. ✓� � ° sou so�� Kerry Joe Jo nso ,LSS Go y sQE Jpy � North Carolina Licensed Soil Scientist#1264 • o,sT, . 11,p ,.► 0 Itiqryg I 1.44;;;;;'1 +9� 1264 � NORTH CP' Kerry Joe Johnson NC Licensed Soil Scientist Subsurface Wastewater System Operator 3311 Old Liberty Rd Franklinville,NC 27248 (336)953-0763 kjoejohnsonsoils@gmail.com K. Joe Johnson Soils and Development Consulting Job Name: Overcash-Jefferson St-PIN 369702873564-Catawba County,NC Owner Information: Owner Name: Tim Collins&Dana Overcash Owner Address: 151 Capital Ave Apartment 3213 Mooresville,NC 28117 Owner Phone#: (704) 880-8649 Property Information: Property Address: 3543 Jefferson St.Sherrills Ford,NC Property Parcel Number: 369702873564 Proposed Use: 2 Bedroom Single Family Residence+2 Bedroom Accessory Dwelling Bedroom Number: 4(2 in main dwelling+2 in accessory dwelling) Design Flow: 480 Max.Occupancy: 8 persons Site LTAR: Initial=0.275_Repair=0.275 House Setback/Setup:30'setback from front property line to porch of home as shown on site plan House Offset: 84'offset from front right property corner to front right corner of home Tanks: Septic Tank Size: 1500 gallon Pump Tank Size: N/A Pump Tank2 Size: N/A Pump/Supply Specifications: Pump Requirements: N/A Supply Line Length &Type: N/A TDH Calculation:N/A Drainfield Specifications: Trench Type:25% Reduction Trench Line Length: 440' Linear Feet Line Depth: 26"MAX trench depth—recommend 22"-26"depth Line Spacing: 9'on center min. Special Notes/Conditions: - Plumb out high and shallow to left side of home and set septic tank shallow to surface(at natural grade)at location shown on site plan. - Run 3"(min.)sch 40 pvc supply line to beginning of drainfield(White-86'on Layout Diagram). - Install 440'of 36"wide chamber trench product in approved initial system area per layout,on contour,and at proper trench depth. - Property lines and corners shall be clearly and accurately(survey)marked before system installation begins. - Construction materials and equipment(vehicles,etc.)must remain off of system area during all phases of construction.Install construction fencing around approved septic system area to protect area during home construction. - Establish vegetative cover over entire system area immediately after installation approval.Use accepted erosion and soil cover stabilization practices for septic area during establishment period of vegetative cover(straw,tar tacking,erosion matting,etc.) - Avoid clearing approved septic area or installation of system while soil conditions are wet.Unapproved grading and/or filling of approved soil area may result in permit revocation - Divert all excess water away from septic system area.Route all gutter downspouts and foundation drains around and away from septic system. - Well area shown meets required setbacks,however permitting of well must meet approval of Catawba County Environmental Health. Kerry Joe Johnson NC Licensed Soil Scientist Subsurface Wastewater System Operator 3311 Old Liberty Rd Franklinville,NC 27248 (336)953-0763 kjoejohnsonsoils@gmail.com Fiii ==,i ;" Site Plan EO SOIL Se C ,��&�JOE J06, '; � 4 F G n�oaM k / 3 . ,__} 2 ib... Repair.Area � 4�\ ...:. :::::::::::.:: : . PRBP$'Vert: Red>ys._` Wh/r :f?':-.•a :. \c f e./47 4s. power pole W Ini\\a, •• - (to be removed) hite 88' 25%Reduction _ 4zEed oom :,. 6276sgft N s :::\:.....•.•'. 5 a4 ` O. .\, \ It‘ ". // Existing Septic `s?', 8x ch System to be '� Abandoned �s7' 30x••Acc.D : Iing E J --•.. o 36' 0 Z� % 0 M • 8x 0 po ch ;1 "• O r` m 10•14 8 well area d m ? -',.. v CI wooden stake Legend: (represents front • Soil Evaluation Locations30'Jefferson St rightcorn6rof <all other values> house envelope)Wood stake is at Area_Type 80'from front right Z3 Initial Area prop.corner and 30' __T_____ from edge of Repair Area right of way. /./ii Potential Well Area r ilia AkIr )�I ,601 u sca, K. Joe Johnson,LSS $01I11,44. NC Licensed Soil Scientist ��`?µ �'� ,. �� G� `- 3311 Old Liberty Rd � �1a .I ( o� �.r• Franklinville,NC 27248 ":4 ^gr'.�,,,,! ,.a (336)953-0763 ?r iz -- Owner: Debra P.Herman Evaluation Date: 2/5/2022 Owner Address: 114 Riverview Acres Ln.Taylorsville,NC 28681 Property Location: 3543 Jefferson St.Sherrills Ford,NC 28673 Proposed Facility: Single Family Residential Water Supply Type: Private Well Property Size: 0.94 acres Evaluation Method: Boring Parcel ID#: 369702873564 Wastewater Type: Domestic Strength Subdivision Name/Lot# Proposed Design Flow: asp GPO Evaluation Method Boring Boring Boring Boring Boring Boring Boring Boring Boring Boring Boring/Pit Number 1 2 3 4 5 6 7 8 Landscape Pos. Linear Linear Linear Linear Linear Linear Linear Linear Slope% 12 10 10 18 14 12 12 12 Horizon 1 Depth(Inches) 0-6 0-21 0-11 0-8 0-5 0-8 0-15 0-6 Horizon 1 Texture SCL SCL SCL SCL SCL SCL C SCL Horizon 1 Structure wBk wBk wBk wBk wBk wBk Bk wBk Horizon 1 Consistence Fr,SS,SP Fr,SS,SP Fr,SS,SP Fr,SS,SP Fr,SS,SP Fr,SS,SP Fi,S,P Fr,SS,SP Horizon 1 Mineralogy SEXP SEXP SEXP SEXP SEXP SEXP SEXP SEXP Horizon 2 Depth(Inches) 6-33 21-48 11-48 8-28 5-24 8-30 15-22 6-25 Horizon 2 Texture C C C C C C CL(BC) C Horizon 2 Structure Bk Bk Bk Bk Bk Bk wBk Bk Horizon 2 Consistence Fi,S,P Fi,S,P FI,S,P Fi,S,P Fi,S,P Fi,S,P Fr,S,P FI,S,P Horizon 2 Mineralogy SEXP SEXP SEXP SEXP SEXP SEXP SEXP SEXP Horizon 3 Depth(Inches) 33-48 28-45 24-41 30-48 22-48 25-38 Horizon 3 Texture CL(BC) CL(BC) CL(BC) CL(BC) L(SAP) CL(BC) Horizon 3 Structure wBk wBk wBk wBk M wBk Horizon 3 Consistence Fr,S,P Fr,S,P Fr,S,P Fr,S,P VFr Fr,S,P Horizon 3 Mineralogy SEXP SEXP SEXP SEXP SEXP Horizon 4 Depth(Inches) 38-48 Horizon 4 Texture L(SAP) Horizon 4 Structure Horizon 4 Consistence Horizon 4 Mineralogy Wetness(Depth/Color) Saprolite(Depth/Inches) 45" 41" 22" 38" Suitability PS PS PS PS PS PS PS PS LIAR 0.325 0.325 0.275 0.275 0.275 0.30 0.10 0.275 Comments: low value Drip-PS SAP lithochromic Need Pit for colors @ 44+, Saprolite Date 2/5/2022 2/5/2022 2/5/2022 2/5/2022 2/5/2022 2/5/2022 2/5/2022 2/5/2022 Sitewide Comments: Initial Trench Type: 25%Reduction Others Present: Donnie Newton,REHS Repair Trench Type: PPBPS(Vertical) Dana Overcash Initial System LIAR: 0.275 Repair System LTAR: 0.275