HomeMy WebLinkAboutAUTH-06-2022-174096.TIF , ' - • CATAW BA COU NTY Case# AIJTH-06-2022-174096
, ...l 2 Public Health Department Subdivision L A CARPENTER
d — "1 Environmental Health Division PIN# 364609067380
PO Box 389,25 Government Drive,Newton,NC 28658 LO"I'# 2
8 qi
Site Address: 203 GOLF COURSE RD, MAIDEN NC 28650
Name on Permit: TRAVIS LAWING
Property Size: Acres.642
Directions: Hwy 321 Turn Rt on South Main, Lot on Left
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-New House
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LTAR: 0.275 g.p.d.Ht2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1,000 gal
Pump Tank 1,000 gal Grease Trap_gal
Dosing Volume 150 gal Pump Specs: 28.81 GPM @ 12.68 TDH
Pressure Head 2 ft Draw Down 7.1 in
Drainfleld: Total Area: 984 sq ft Total Trench Length: 328 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 18 in
Minimum Soil Cover: 8 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 4 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
-Install new 1000 gal septic and pump tank(s) and 328 feet of 25%reduction product according to manufacturer
specifications.
-Septic and repair areas must remain 5 feet from building structure, 10 feet from property lines and 10 feet from
water lines.
-Pressure manifold sheet attached with permit.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.275
g.p.d.lft2
Proposed System: 50%REDUCTION HORIZONTAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
,liiuimr 06./23/2022 09:08