Loading...
HomeMy WebLinkAboutAUTH-06-2022-173717.TIF eew\ (ATAWBA('Ot:NTY case# AIM I-06-2022-1737 1 7 Lt ?1 Public Health Department Subdivision d 1 „yt Environmental Ilcalth Division PIN# 374413243956 i . PO Box 389.25 Government Drive.Newton.NC 28658 LU'I N 2 f84/ " Site Address: 1215 HOUSTON DR, CONOVER NC 28613 Name on Permit: REGINA BRENDLE Property Size: Acres 1.46 Directions: Houston Rd 2 story white house Authorization to Construct Permit Permit Category: Repairs Wastewater Flow: 360 g.p.d. Type of Facility: Primary Residence- Repair Basement? No Basement Plumbing? No Bedrooms: 3 Water Supply: Private Well Maximum Occupants: 6 Soil LTAR: 0.225 g.p.d.Ift2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 25%REDUCTION System Classification: IIIG-OTHER NON-CONV TRENCH SYSTEMS Septic Tank: New Tank: 1,000 gal Pump Tank _gal Grease Trap_gal Dosing Volume gal Pump Specs: GPM @ TDH Pressure Head ft Draw Down in Drainfield: Total Area: 1,206sq ft Total Trench Length: 402 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 18 in Minimum Soil Cover: 6 in Minimum Trench Separation: 8 ft on center Number of Drain Lines: 5 Trench Width: 3 ft Distribution: Serial Pre Treatment: NONE Pump *May Be* Required Additional Specifications: -Existing septic tank may be used if it is in good condition and meets current rules. -If not used new 1000 gal septic tank will need to be installed. -Existing septic tank must be properly abandoned(pumped, crushed and filled). -Install 400 feet of 25%reduction according to manufacturer specifications. -Pump MAY BE required if proper fall can not be reached from septic tank to drainfield location. -All septic areas must remain 10 feet from property lines, and 5 feet from building structure. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Not Required,has space Soil LIAR: 9•P•d.ft2 Proposed System: System Classification: rlrp�ruin 116.7II:2n22 i-li i $ CATAWBA COUNTY Case# AUTH-06-2022-173717 Public Health Department Subdivision lGi Environmental Health Division PW# 374413243956 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 2 !g Site Address: 1215 HOUSTON DR, CONOVER NC 28613 Name on Permit: REGINA BRENDLE Property Size: Acres 1.46 Directions: Houston Rd 2 story white house The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rules for Sewaee Treatment and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. 37Art °'477( 06/15/2022 Authorized State Agent Permit Issuance Date 6/15/2027 Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department. ehpennit 06/15/2022 09:25 Catawba County Environmental Health - EN?R-o`l- zo11 - ypLotto`, w `el- 2� Au44-06 -Z.21-1739-1?- `\ r IN N. }L`t S X .121 `1 ct \b Qloµ _` P \ I F� 5t r • ''\ \-- v t \�40 ‘NO '��f �`Z� ko r \ -S� • .tyMry .,r'ry \ 'r', L V fr �-� \ ' t ,, 243.48 s \1, 167.59 - ,,1611 -^ Ro Parcel: 374413243956, 1215 HOUSTON DR 1in=40ft CONOVER, 28613 This map/report product was prepared from the Catawba County.NC Geospatial Information Services. Catawba County has made substantial efforts to ensure the accuracy of location and labeling information contained on this map or data on this report.Catawba County promotes and rttummends the independent venficabon of any data contained on this map/report product by the user Tho County of Catawba,its employees,agents,and personnel,disclaim.and shall not be held!table for any and all damages,loss or Ilabrhty,whether direct,Indirect or consequential which arises or may arise from this map/report product or the use thereof by any person or entity. Copyright 2021 Catawba County NC 06/14/2022 DEPARTMENT OF HEAL-ph AND HUMAN SERVICES Sheer , of i. DIVISION OF PUBLIC HEALTH,ENVIRONMENTAL HEALTH SECTION PROPERTY ID#: 3 /Y132y3ffti ON-SITE WATER PROTECTION BRANCH COUNTY: (.*e'. SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM (Complete all fields in full) OWNER: d1 _ APPLICATION DATE 7(Y Z Z ADDRESS: f o T e 3 DATE EVALUATED: PROPOSED FACILITY: ',pi( PROPOSED DESIGN FLOW(.1949): 340 6PD PROPERTY SIZE: LOCATION OF SITE: Sa L _ // PROPERTY RECORDED: WATER SUPPLY: [►3'Private ❑Public Q'Well 0 Spring ❑Other EVALUATION METHOD: ❑Auer Boring [Wit 0 Cut TYPE OF WASTEWATER: I KSewage 0 Industrial Process 0 Mixed • • P R o SOIL MORPHOLOGY OTHER F (.1941) PROFILE FACTORS 1 L .1940 E LANDSCAPE HORIZON POSITION! DEPTH PROFILE SLOPE% (IN.) .1941 .1941 SOIL .1943 .1956 .1944 CLASS STRUCTURE/ CONSISTENCE! WETNESS/ SOIL_ SAPRO RESTR Se LTAR TEXTURE MINERALOGY COLOR DEPTH CLASS HORIZ L 5 0-g Cl- 36K ,Fr, 5s,sp,sfxf 2.5 Y r 6--32 C'- W5�' Fr,S, se, stxf9 7/,' (3zt ( 11S 1 p J 3Z-5/ c wsc�c .f/ 3t-5(E sEx1 7.51 , 5 r 1° 7/t-13z 2. 225 4—i 1,-C. 0--9 CA- s�6K rf,ss,se, sEy 5 9_3(o C S$K i`r/S/S ,,5 , II 20/ 3(0 -(0z C G�S6le F 5 3;9/ 5 (9 2 p. Z15 Ls 0-/0 sax 6, ss,5,.sve 2. 5 �' P s �0_30 c� Sixr � �i �P3 s sp+six . !+ it 3 so -3(0 C Gael( 413 S s La" 58 . 0 3(,)--ss' C. 46It Ff, s1sprfeYP 3-1 y-z 3,' D. 2 25- ss , 4 DESCRIPTION INITIAL.SYSTEM REPAIR SYS'I'I M OTHER FACTORS(.1Q46): [ S J SITE CLASSIFICATION(.1948): 9S Available Space(.1945) / r 1_ System T'Pe(s) 75010 t _./ N j4 EVALUATED BY: l�L_l{:Ci L_biti2 Tv, ( e[( n�//]� OTHER(S)PRESENT: J (Qilkt“.. c Site LIAR 0. ZZ5 ` `� r, J COMMENTS:_ Updated February 2014 A. I i E U Catawba County Environmental Health .� "`.�- �1.tpR- t3y-zo?Z -yo boy \ ''"�2Az� 1)144,-olo -Zort-173?-17- • ... - Drive way \ti 4 `‘. a P , \ S\ \ ` 4 tk ill st . am 243.48 167.59 •9,,, Parcel: 374413243956, 1215 HOUSTON DR 1in=40ft CONOVER, 28613 This map/report product was prepared from the Catawba County,NC Goospatlal Information Services. Catawba County has made substantial efforts to ensure the accuracy of location and laboling information containod on this map or data on this report.Catawba County promotes and recommends the Independent verification of any data containod on this map/report product by the user.The County of Catawba,Its employees,agents,and personnel.disclaim,and shall not be held liable for any and all damages,loss or liability,whether direct,Indirect or consequential which arises or may arise from this map/report product or tho use thereof by any parson or ontity. Copyright 2021 Catawba County NC 06/1412022