HomeMy WebLinkAboutAUTH-06-2022-173450.TIF 3y�3' CAI'AWBACOUNTY Case# AUTH-06-2022-173450
.t. .4 Public Health Department Subdivision
„11 O Environmental Health Division PIN# 360904519279
PO Box 389,25 Government Drive.Newton,NC 28658 LOT# 1
/g 2 w
Site Address: 2200 TIPPS RD, HICKORY NC 28602
Name on Permit: MARICE TIPPS
Property Size: Acres 0.48
Directions: Hwy 10 E, Right Rhoney School RD, Right Tipps RD at very end
Authorization to Construct Permit
Permit Category: Expansion Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-New House
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LTAR: 0.275 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50%REDUCTION VERTICAL
System Classification: IIIE-PPBPS GRAVITY DOSED SYSTEM
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 144 sq ft Total Trench Length: 72 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 33 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 8 ft on center
Number of Drain Lines: 2 Trench Width: 2 ft
Distribution: Distribution Box
Pre Treatment: NONE
Additional Specifications:
-Existing septic tank may be used if it is in good condition and meets the current rules.
-New distribution box will need to be installed.
-Install 72 feet of 50%reduction product(vertical)according to manufacturer specifications.
-Each new line will contain 8 panels.
-Install new drop box to equal feed expansion.
-All parts of the septic system MUST remain 10 feet from property lines, 5 feet from building structures(this
includes decks)and 10 feet from water lines.
-Water line MUST remain 10 feet from septic system area.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.1375g.p.d.fft2
Proposed System: DRIP IRRIGATION
System Classification: VA-SAND FILTER PRETREATMENT
Pump Required ***** Operator Required
ehpennit 06/17/2022 11:03