HomeMy WebLinkAboutAUTH-06-2022-173465.TIF -411ilmik � CATAWBA COUNTY Case# AUTH-06-2022-173465
i� t f 7 Public Health Department Subdivision
'< '3 Environmental Health Division PIN# 372118425084
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
is..._ su
Site Address: 2466 STARTOWN RD, NEWTON NC 28658
Name on Permit: ANDREA LUTZ YOUNG
Name on Permit: BILLY YOUNG
Property Size: Acres 3.55
Directions: Startown rd to valley view dr house is beside of the house of 2603 valley view drive
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 240 g.p.d.
Type of Facility: Primary Residence-SFD
Basement? No Basement Plumbing? No Bedrooms: 2
Water Supply: Private Well Maximum Occupants: 4
Soil LTAR: .3 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 2ft wide chambers
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 536 sq ft Total Trench Length: 268 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 14 in
Minimum Soil Cover: 8 in Minimum Trench Separation: 6 ft on center
Number of Drain Lines: 4 Trench Width: 2 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*KEEP SYSTEM UP HILL AS MUCH AS POSSIBLE
*EXIT PLUMBING WILL HAVE TO BE RAISED TO MAINTAIN PROPER TRENCH DEPTH
*14 INCH MAX TRENCH DEPTH NO EXCEPTIONS
*2 FT WIDE CHAMBERS INSTALLED ON CONTOUR
*6FT ON CENTER
*DO NOT GET IN LOW WET AREA
*CONTACT EHS TO LAYOUT SYSTEM AREA IF NEEDED
*DEFINE DRAINAGE WAY
*FINAL GRADE SHALL HAVE MIN 8 INCHES OF COVER AND BE STABILIZED(SEEDED AND STRAWED)
WITHIN 14 DAYS OF INSTALLATION
*EXISTING SEPTIC TO BE ABANDONED
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: .3 g.p.dlft2
ahprnnit 06/13/2022 09:50