HomeMy WebLinkAboutAUTH-06-2022-173081.TIF rPublice•
CATAWBA COUNTY Case# AUTI 1 06 2022 173081
f.
ic Health Department Subdivision
Environmental Health Division PIN# 376008987770
PO Box 389,25 Government Drive,Newton,NC 28658 I,OTt, 2
Site Address: 3998 E NC 10 HWY, CLAREMONT NC 28610
Name on Permit: *BARRY&SAVANNAH HUFFMAN
Property Size: Acres 9.81
Directions: Left on Hwy 10 from Balls Creek School Rd, Go about 1 mile, Driveway on Right
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 240 g.p.d.
Type of Facility: Accessory Dwelling-
Basement? No Basement Plumbing? No Bedrooms: 2
Water Supply: Public Water Maximum Occupants: 4
Soil LIAR: 0.275 g.p.dJft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 654 sq ft Total Trench Length: 218 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 32 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*Do not cut, drive,fill, or grade over septic or repair areas.
*Septic system must be 10 ft from property lines, 50 feet from wells, 5 ft from building foundations and
appurtenances, and out of right-of-ways and easements.
*Install a 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface).
*Install 218 linear feet of 25% reduction system, proposed 3 lines total at 70 ft, 74 ft, and 74 ft on contour.
*Final grade of septic area must shed surface water off and away from system.
*All gutter drains must be routed away from the septic system.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existinq permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LIAR: 0.25 9•p•dJft2
Proposed System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Pump *May Be* Required
cr 1 ciwi1 01/30/2023 14:27