Loading...
HomeMy WebLinkAboutAUTH-06-2022-173081.TIF rPublice• CATAWBA COUNTY Case# AUTI 1 06 2022 173081 f. ic Health Department Subdivision Environmental Health Division PIN# 376008987770 PO Box 389,25 Government Drive,Newton,NC 28658 I,OTt, 2 Site Address: 3998 E NC 10 HWY, CLAREMONT NC 28610 Name on Permit: *BARRY&SAVANNAH HUFFMAN Property Size: Acres 9.81 Directions: Left on Hwy 10 from Balls Creek School Rd, Go about 1 mile, Driveway on Right Authorization to Construct Permit Permit Category: New Septic Wastewater Flow: 240 g.p.d. Type of Facility: Accessory Dwelling- Basement? No Basement Plumbing? No Bedrooms: 2 Water Supply: Public Water Maximum Occupants: 4 Soil LIAR: 0.275 g.p.dJft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 25%REDUCTION System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS Septic Tank: New Tank: 1,000 gal Pump Tank _gal Grease Trap_gal Dosing Volume gal Pump Specs: GPM @ TDH Pressure Head ft Draw Down in Drainfield: Total Area: 654 sq ft Total Trench Length: 218 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 32 in Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center Number of Drain Lines: 3 Trench Width: 3 ft Distribution: Serial Pre Treatment: NONE Additional Specifications: *Do not cut, drive,fill, or grade over septic or repair areas. *Septic system must be 10 ft from property lines, 50 feet from wells, 5 ft from building foundations and appurtenances, and out of right-of-ways and easements. *Install a 1,000 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface). *Install 218 linear feet of 25% reduction system, proposed 3 lines total at 70 ft, 74 ft, and 74 ft on contour. *Final grade of septic area must shed surface water off and away from system. *All gutter drains must be routed away from the septic system. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation, or the suspension/revocation of existinq permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Required Soil LIAR: 0.25 9•p•dJft2 Proposed System: 25%REDUCTION System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS Pump *May Be* Required cr 1 ciwi1 01/30/2023 14:27