HomeMy WebLinkAboutAUTH-06-2022-172885.TIF .lyl • CATAWBA COUNTY Case# AUTI 1.06-2022-172885
z.
!4(.....
h . Public Health Department Subdivision
d '3 Environmental Health Division PIN# 373410359871
PO Box 389,25 Government Drive,Newton,NC 28658 LOT#
8. s,
Site Address: 1640 GRAND DR, CONOVER NC 28613
Name on Permit: *DANA&KELLY HARGETT
Property Size: Acres 4.67
Directions: Turn into canterbury park from springs rd follow canterbury to grand driver fork off to right at property line
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-SFD
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LTAR: .25 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25°A) REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
Septic Tank: New Tank: 1,000 gal
Pump Tank _gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 1,080sq ft Total Trench Length: 360 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 32 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 3 Trench Width: 3 ft
Distribution: Serial
Pre Treatment: NONE
Additional Specifications:
*INSTALL ON CONTOUR
*SEPTIC TANK PER BEST LOCATION
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: .25 9•p•d.lft2
Proposed System: 25%REDUCTION
System Classification: IIIG-OTHER NON-CONY TRENCH SYSTEMS
L;:c m,i; 03/06/2023 13:42