HomeMy WebLinkAboutAUTH-06-2022-172832.TIF �• . . t '•,. '
r
Y
•..eX,A i'‘CATAWBA COUNTY Case I1 AUTH-06-2022-I 72832
A(.1,4 Public Health Department Subdivision ST JAMES VINEYARD PH 2
3 (� ,� Environmental Health Division PINS 375008885415
4. PO Dori 389,25 Government Drive,Newton,NC 28658 '
•'� �� LOTS 58
. . •:,� :;¢..gip•.. •
Site Address: 1531 ANTIOCH DR,CONOVER NC 28613 •
Name on Permit 'HELMSMAN HOMES,LLC .
Property Size: Acres 0.52 •
Directions: take right off of Judea Dr•onto Antioch Dr.3rd lot on right.
Owner/Authorized Representative Acknowledgement of Permit Receipt
(.certify that I am the owner or authorized agent(owner's authorization required)representing the owner of
the.property described above. •
•
• x,• ){ As the property owner or authorized representative, I have received the above referenced
,,"" permit(s)as requested in the application for service RBPR-11-2021-39361,by the following method(s):
• Received in Person •
Facsimile Transmittal(Return form with signature required)
Y Electronic Image Transmittal/E-mail (Return receipt•required) .
As the property owner or authorized representative 1 have reviewed and understand the specific conditions
:• of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina,Laws and Rules for:Sewage Treatment and Disposal Systems.(15A NCAC 18A.1900),'
and/or.Well Construction Standards.(15A NCAC 2C.0100), shall:apply to the issuance of this permit and • �''
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date:06/03/2022
Owner/Authorized Representative Signature A, egA
Date l0 1'7 12,4 iz
r
Documentation of Permil(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by (name of person sending permit)
Signature Date/Time IP/7f)) ,
. (-1/ .
Method: Fax Email •• US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature .
We wantt no hear from yo2Please ttake a few momentts tto complette our custtomer service survey att • :r.
• http://www.surveymonkey.com/s/EHCusttomerService • • •
5 r‘Ie4er'@he1 Arts/MA herfla.eel
ehpennit 06/03/2022 16:06
•
1' \
rCATAWBA COUNTY Cased AUTH-06-2022-172832
Public Health Department Subdivision ST JAMES VINEYARD PH 2
Environmental Health Division
t PINd 375008885415
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 58
w
Site Address: 1531 ANTIOCH DR, CONOVER NC 28613
Name on Permit: *HELMSMAN HOMES, LLC
Property Size: Acres 0.52
Directions: take right off of Judea Dr onto Antioch Dr. 3rd lot on right.
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-New House
Basement? No Basement Plumbing? No Bedrooms: 3
Water Supply: Public Water Maximum Occupants: 6
Soil LTAR: 0.3 g.p.d.l1t2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25%REDUCTION
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1,000 gal
Pump Tank 1.000 gal Grease Trap_gal
Dosing Volume 137 gal Pump Specs: 28.81 GPM @ 20.87 TDH
Pressure Head 2 ft Draw Down 6.5 in
Drainfield: Total Area: 900 sq ft Total Trench Length: 300 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 24 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 4 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
-Do not drive, grade, cut or fill over any part of the initial or repair septic areas.
-Install new 1000 gal septic and pump tanks.
-Install 300 feet of 25%reduction according to manufacturer specifications.
-Pressure manifold sheet attached.
-Septic areas(including septic tanks) MUST be located 15 feet from foundation drains.
-GATE VALVE REQUIRED
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation,or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: 0.3 g.p.d.lft2
Proposed System: 50%REDUCTION VERTICAL
System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION
Pump Required ***** Operator Required
chpemiil 06/06/2022 10:58
_� CATAWBA COUNTY Case# AUTH-06-2022-172832
1,..7 t Public Health Department
USubdivision ST JAMES VINEYARD PH 2
d -� "4 Environmental Health Division PIN# 375008885415
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 58
/„Et sw
Site Address: 1531 ANTIOCH DR, CONOVER NC 28613
Name on Permit: *HELMSMAN HOMES, LLC
Property Size: Acres 0.52
Directions: take right off of Judea Dr onto Antioch Dr. 3rd lot on right.
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Carus and Rules for Sewage Treatment and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the •
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
°111/61ft °//6'\
06/03/2022
Authorized State Agent Permit Issuance Date
11/4/2026
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
eltpennit 06/03/2022 16:06
Catawba County Environmental Health
ril - i l- Zo2/ - 3'931
ob _ ?1°2Z - liz?sz
a
c , 7e3 `
't 1 Q7
t' \y l ' 20' ``"'
a 3Q� .�
/•
N( gtQF'` o /tl,? 33 , Drl
vc
5' I f 55
1 a I30 IAJ
V4
4-
1 3y 13 W"15,T% �1q�` 62.99.f
� J
It t q rta
i RcF5o'X 35' i t
f l� � i 33.32
\i„....
III
• _ , _.1.---.1.—....*••••••••LIV...............^.•
f 3 3Y 1 (eo` 76+
s�
.`fir
Parcel: 375008885415, 1531 ANTIOCH DR tin=40ft
CONOVER, 28613
This map/report product was prepared from the Catawba County,NC Gaospaltal Information Services. Catawba County has made substantial efforts
to ensure the accuracy of location and labeling Information contained on this map or data on this report.Catawba County promotes and recommends
the independent verification of any data contained on this maplraporl product by the user.Tho County of Catawba,its employe,agents,and
personnel,disclaim,and shall not be held liable for any and aid{damages,loss or liability,whether direct,Indiroct or consequential which arises or may
arise from this map/report product or the use thereof by any person or entity.
Copyright 2021 Catawba County NC
06/03/2022
.... ../..A.4011w41';µ.art' .
6
SYSTEM
Line# Color Elevation Length Hole Size Flow/Tap gp Trench Area Cony LTAR 25%LTAR 50%LTAR
1 66 SCH 80 1/2 5.48 28.00 198 0.14 0.11 0.07
2 78 SCH 40 1/2 7.11 36.33 234 0.16 0.12 0.08
3 78 SCH 40 1/2 7.11 36.33 234 0.16 0.12 0.08
4 78 SCH 40 1/2 7.11 36.33 234 0.16 0.12 0.08
total feet = 300 gal/min= 26.81 137.00 900.00 0.15 0.11 0.08
Des.Flow 360
Pump Run= 5.11
soil LTAR 0.3