HomeMy WebLinkAboutAUTH-06-2022-172800.TIF .-:,,A,,-
�c !►e� CATAWBA COUNTY
.f. Public Health Department Subdivision THE SUMMIT AT LAKE NORM
'. .� it Environmental Health Division PIN" 471001075144
7�Y PO Box 389,25 Government Drive,Newton,NC 28658 LOTH 5
Site Address: 8283 LONG ISLAND RD,CATAWBA NC 28609
Name on Permit: 'FOUNDATION HOMES RESIDENTIAL LLC
Property Size: Acres 1.89
Directions: Hwy 150 to 7.2 miles, Right Sherrills Ford RD,go 3 miles, Right Mollys Backbone,Left on Monbo RD, Right
Long Island RD
Owner/Authorized Representative Acknowledgement of Permit Receipt
X mcv I certify that I am the owner or authorized agent(owner's authorization required) representing the owner of
11�`the property described above.
mCa As the property owner or authorized representative, I have received the above referenced
permit(s)as requested in the application for service RBPR-04-2022-40702, by the following method(s):
Received in Person
Facsimile Transmittal(Return form with signature required)
. Electronic Image Transmittal/ E-mail (Return receipt required)
')( mc°As the property owner or authorized representative I have reviewed and understand the specific conditions
of the permit issued, and further understand that all applicable regulatory requirements specified under the
North Carolina Laws and Rules for Sewage Treatment and Disposal Systems (15A NCAC 18A.1900),
and/or Well Construction Standards (15A NCAC 2C .0100), shall apply to the issuance of this permit and
the construction of the wastewater system and/or water supply well permitted.
Permit Issue Date: 06/03/2022
Owner/Authorized Representative Signature 044y¢x�
Date 06/06/2022
Documentation of Permit(s)Transmittal
(permit transmitted by electronic or other means)
Permit transmitted by �J (name of person sending permit)
Signature_ i, v Date/Time
ELL
Method: Fax J Email US Mail Other
Owner's request to send by the above indicated method of transmittal in lieu of signature
We wantt tto hear from yoiPlease ttake a few momentts tto complette our custtomer service survey att
http://www.surveymonkey.com/s/EHCusttomerService
iv' ; fr?.{ tkanda c�h, LsPelt.G:in
ebpenml 00/06/2022 10.12 e
�%\• CATAWBA COUNTY Case# AUTI1-06-2022-172800
N t Public Health Department Subdivision THE SUMMIT AT LAKE NORM
ti(.......,- ) „,1�, Environmental Health Division PINK 4571001075144
PO Box 389,25 Government Drive,Newton,NC 28658 LOT1i 5
I: w
Site Address: 8283 LONG ISLAND RD, CATAWBA NC 28609
Name on Permit: *FOUNDATION HOMES RESIDENTIAL LLC
Property Size: Acres 1.89
Directions: Hwy 150 to 7.2 miles, Right Sherrills Ford RD,go 3 miles, Right Mollys Backbone, Left on Monbo RD, Right
Long Island RD
Authorization to Construct Permit
Permit Category: New Septic Wastewater Flow: 480 g.p.d.
Type of Facility: Primary Residence-
Basement? Yes Basement Plumbing? Yes Bedrooms: 4
Water Supply: Private Well Maximum Occupants: 8
Soil LTAR: .3 g.p.d.lft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 25% REDUCTION
System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP
Septic Tank: New Tank: 1,000 gal
Pump Tank 1,000 gal Grease Trap_gal
Dosing Volume 175 gal Pump Specs: 29.4 GPM @ 64 TDH
Pressure Head 2 ft Draw Down 8'7 in
Drainfield: Total Area: 1,200sq ft Total Trench Length: 400 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 36 in
Minimum Soil Cover: 12 in Minimum Trench Separation: 9 ft on center
Number of Drain Lines: 5 Trench Width: 3 ft
Distribution: Pressure Manifold
Pre Treatment: NONE
Pump Required
Additional Specifications:
Proposal from Michael Athanas LSS was reviewed in field on 5/26/2022.
Keep all parts of septic system and any future repair system minimum:50'from any individual well, 10'from
property lines, 15'from pool, 25'upslope from building foundations, 10'downslope from building foundations, 10'
from any water or utility lines. Tanks must be 50'from lake 760 contour.
Lines to be installed on contour and as shown on site plan. Use a schedule 80 pressure manifold with (5) 1/2"
schedule 80 taps.
Do not grade,drive,or fill over system or repair area or permit may be revoked.Any deviation from site plan and
proposed house will require a revised proposal from LSS.Septic repair system must be designed by an
engineer.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation.or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Required Soil LTAR: .125 9-p-d./ft2
,, rr''It 06/06t2022 I I:54
44,��• CATAWBA COUNTY Case# AUTH-06-2022-I 72800
1r.t. Public Health Department Subdivision THE SUMMIT AT LAKE NORM
1 Environmental Health Division PIN# 471001075144
\101111! PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 5
Site Address: 8283 LONG ISLAND RD,CATAWBA NC 28609
Name on Permit: *FOUNDATION HOMES RESIDENTIAL LLC
Property Size: Acres 1.89
Directions: Hwy 150 to 7.2 miles, Right Sherrills Ford RD,go 3 miles, Right Mollys Backbone, Left on Monbo RD, Right
Long Island RD
Pump Required ***** Operator Required
The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant
/property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements arc met. This Authorization to
Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to
Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the
North Carolina'Laws and Rulesfor Sewage Treatment and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the
Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time.
Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit
modification.Please notify Environmental Health of this change prior to system installation.
1
06/03/2022
Authorized State Agent Permit Issuance Date
6/3/202 7
Permit Expiration Date
No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department.
ehpennit 06/06/2022 10:13
.........":". ....s.......... ......,„.....„.....,.................
N 60...AA
RD.
P 1
\ PM B2 ABA•
„;it 5 • ` ` `W3 °Pit 4
C�4
\ Y5 APPROXIMATE ST UCTURAL/IMPERVIO
\ . , \ APPROXIMATE PI4OPERTYAREA:82,45
\ Pit 3 -\-• PROPOSED DWELLING AREA:3,096 SF,
P1 80' \ ,V�.--- \ PROPOSED PATIO/PORCH AREA:276 S
B2PROPOSED DRIVE/SIDE WALK AREA: 6
W3 80 \ PROPOSED POOIIAREA:1,400 SF,0.032
80' /� ,, \• APPROXIMATE STRUCTURAL COVERA(
04 80' APPROXIMATE IMPERVIOUS COVERAG
Y5-80' /
Complex ` '``
Topography' A Old drive
,
/ ',
\ .
/ '' \
i Scale
• \ 1"=60'
AB 3 \ \
at
.
Repair',
Area
\ 0
-o\ Pit LP
0
.o ' ` \
1'�\ AB I \
a\\ \
o \
kok-
\ '',.-- ,\ A X‘t-'
1 PT i, Q��` \\
f
ST /� \
s
\ "-5. \ 0,
5 0' �cw i
, 14b6(� 5sT00 \ - ' .)
ST
NORMAN-SECTION 2-AS
)UNTY REGISTRY.
IVENANTS LISTED IN D.B.2097, •
1871,&D.B. 2768,PG. 1507.
'NING AND PLANNING
Y.AND RESTRICTIONS OF + V/
Hci
MA&A
SOIL&ENVIRONMENTAL CONSULTANTS
MICHAEL ATHANAS &ASSOCIATES
LICENSED SOIL SCIENTIST
556 Walden Trail
Weddington,NC 28173
(704)576-3887
3/28/2022
Reference: Data Sheet for 8283 Long Island Rd1 The Summit at Lake Norman, Lot 5
House Footprint: See attached plan
Building Setbacks: 30' front, 15' side, lake 50'
Water Source: Private well
Number of Bedrooms/Daily Flow: 4/480 GPD
Proposed LTAR: 0.3 GPD/FT2
Proposed System Type: 25% Reduction
Proposed Repair System Type: Drip Dispersal
Distribution: Pressure Manifold
Flow per Tap: 5.48 GPM
Tap Size and Material: 'A" SCH 80
System Flow: 27.4 GPM
Dosing Volume: 175 gallons
Pump Run Time: 6.4 minutes
Elevation Head: TBD
Friction Head: 8.9'
Pressure Head: 2'
Total Dynamic Head: TBD
Supply Line Length: 480' OF 2" PVC
Septic/Pump Tank Size: 1000/1000 gallons
Proposed Trench Bottom: 36" (initial), 12" (repair)
Line Design Length Actual Length Elevation
Pink 1 80' 80'
Blue 2 80' 80' T
White 3 80' 80' B
Orange 4 80' 80' D
Yellow 5 80' 80'
Initial System: 480' Repair System: 4800 FT2
Pump Tank: TBD House Corner: TBD
Benchmark: TBD
Comments:
Please note this design is only intended for the use of two people per bedroom for a total design
flow of 480 GPD and a total occupancy of 8 people. It is intended for residential use only, no
commercial use. Please note once a septic system reaches 80% of the designed flow you are
reaching the maximum ability of the septic system. Additional occupancy could lead to
premature failure of the septic system.