Loading...
HomeMy WebLinkAboutAUTH-06-2022-172800.TIF .-:,,A,,- �c !►e� CATAWBA COUNTY .f. Public Health Department Subdivision THE SUMMIT AT LAKE NORM '. .� it Environmental Health Division PIN" 471001075144 7�Y PO Box 389,25 Government Drive,Newton,NC 28658 LOTH 5 Site Address: 8283 LONG ISLAND RD,CATAWBA NC 28609 Name on Permit: 'FOUNDATION HOMES RESIDENTIAL LLC Property Size: Acres 1.89 Directions: Hwy 150 to 7.2 miles, Right Sherrills Ford RD,go 3 miles, Right Mollys Backbone,Left on Monbo RD, Right Long Island RD Owner/Authorized Representative Acknowledgement of Permit Receipt X mcv I certify that I am the owner or authorized agent(owner's authorization required) representing the owner of 11�`the property described above. mCa As the property owner or authorized representative, I have received the above referenced permit(s)as requested in the application for service RBPR-04-2022-40702, by the following method(s): Received in Person Facsimile Transmittal(Return form with signature required) . Electronic Image Transmittal/ E-mail (Return receipt required) ')( mc°As the property owner or authorized representative I have reviewed and understand the specific conditions of the permit issued, and further understand that all applicable regulatory requirements specified under the North Carolina Laws and Rules for Sewage Treatment and Disposal Systems (15A NCAC 18A.1900), and/or Well Construction Standards (15A NCAC 2C .0100), shall apply to the issuance of this permit and the construction of the wastewater system and/or water supply well permitted. Permit Issue Date: 06/03/2022 Owner/Authorized Representative Signature 044y¢x� Date 06/06/2022 Documentation of Permit(s)Transmittal (permit transmitted by electronic or other means) Permit transmitted by �J (name of person sending permit) Signature_ i, v Date/Time ELL Method: Fax J Email US Mail Other Owner's request to send by the above indicated method of transmittal in lieu of signature We wantt tto hear from yoiPlease ttake a few momentts tto complette our custtomer service survey att http://www.surveymonkey.com/s/EHCusttomerService iv' ; fr?.{ tkanda c�h, LsPelt.G:in ebpenml 00/06/2022 10.12 e �%\• CATAWBA COUNTY Case# AUTI1-06-2022-172800 N t Public Health Department Subdivision THE SUMMIT AT LAKE NORM ti(.......,- ) „,1�, Environmental Health Division PINK 4571001075144 PO Box 389,25 Government Drive,Newton,NC 28658 LOT1i 5 I: w Site Address: 8283 LONG ISLAND RD, CATAWBA NC 28609 Name on Permit: *FOUNDATION HOMES RESIDENTIAL LLC Property Size: Acres 1.89 Directions: Hwy 150 to 7.2 miles, Right Sherrills Ford RD,go 3 miles, Right Mollys Backbone, Left on Monbo RD, Right Long Island RD Authorization to Construct Permit Permit Category: New Septic Wastewater Flow: 480 g.p.d. Type of Facility: Primary Residence- Basement? Yes Basement Plumbing? Yes Bedrooms: 4 Water Supply: Private Well Maximum Occupants: 8 Soil LTAR: .3 g.p.d.lft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 25% REDUCTION System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP Septic Tank: New Tank: 1,000 gal Pump Tank 1,000 gal Grease Trap_gal Dosing Volume 175 gal Pump Specs: 29.4 GPM @ 64 TDH Pressure Head 2 ft Draw Down 8'7 in Drainfield: Total Area: 1,200sq ft Total Trench Length: 400 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 36 in Minimum Soil Cover: 12 in Minimum Trench Separation: 9 ft on center Number of Drain Lines: 5 Trench Width: 3 ft Distribution: Pressure Manifold Pre Treatment: NONE Pump Required Additional Specifications: Proposal from Michael Athanas LSS was reviewed in field on 5/26/2022. Keep all parts of septic system and any future repair system minimum:50'from any individual well, 10'from property lines, 15'from pool, 25'upslope from building foundations, 10'downslope from building foundations, 10' from any water or utility lines. Tanks must be 50'from lake 760 contour. Lines to be installed on contour and as shown on site plan. Use a schedule 80 pressure manifold with (5) 1/2" schedule 80 taps. Do not grade,drive,or fill over system or repair area or permit may be revoked.Any deviation from site plan and proposed house will require a revised proposal from LSS.Septic repair system must be designed by an engineer. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and may result in failure to approve the initial system installation.or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Required Soil LTAR: .125 9-p-d./ft2 ,, rr''It 06/06t2022 I I:54 44,��• CATAWBA COUNTY Case# AUTH-06-2022-I 72800 1r.t. Public Health Department Subdivision THE SUMMIT AT LAKE NORM 1 Environmental Health Division PIN# 471001075144 \101111! PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 5 Site Address: 8283 LONG ISLAND RD,CATAWBA NC 28609 Name on Permit: *FOUNDATION HOMES RESIDENTIAL LLC Property Size: Acres 1.89 Directions: Hwy 150 to 7.2 miles, Right Sherrills Ford RD,go 3 miles, Right Mollys Backbone, Left on Monbo RD, Right Long Island RD Pump Required ***** Operator Required The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements arc met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rulesfor Sewage Treatment and Disposal Systems' (15A NCAC 18A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. 1 06/03/2022 Authorized State Agent Permit Issuance Date 6/3/202 7 Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department. ehpennit 06/06/2022 10:13 .........":". ....s.......... ......,„.....„.....,................. N 60...AA RD. P 1 \ PM B2 ABA• „;it 5 • ` ` `W3 °Pit 4 C�4 \ Y5 APPROXIMATE ST UCTURAL/IMPERVIO \ . , \ APPROXIMATE PI4OPERTYAREA:82,45 \ Pit 3 -\-• PROPOSED DWELLING AREA:3,096 SF, P1 80' \ ,V�.--- \ PROPOSED PATIO/PORCH AREA:276 S B2PROPOSED DRIVE/SIDE WALK AREA: 6 W3 80 \ PROPOSED POOIIAREA:1,400 SF,0.032 80' /� ,, \• APPROXIMATE STRUCTURAL COVERA( 04 80' APPROXIMATE IMPERVIOUS COVERAG Y5-80' / Complex ` '`` Topography' A Old drive , / ', \ . / '' \ i Scale • \ 1"=60' AB 3 \ \ at . Repair', Area \ 0 -o\ Pit LP 0 .o ' ` \ 1'�\ AB I \ a\\ \ o \ kok- \ '',.-- ,\ A X‘t-' 1 PT i, Q��` \\ f ST /� \ s \ "-5. \ 0, 5 0' �cw i , 14b6(� 5sT00 \ - ' .) ST NORMAN-SECTION 2-AS )UNTY REGISTRY. IVENANTS LISTED IN D.B.2097, • 1871,&D.B. 2768,PG. 1507. 'NING AND PLANNING Y.AND RESTRICTIONS OF + V/ Hci MA&A SOIL&ENVIRONMENTAL CONSULTANTS MICHAEL ATHANAS &ASSOCIATES LICENSED SOIL SCIENTIST 556 Walden Trail Weddington,NC 28173 (704)576-3887 3/28/2022 Reference: Data Sheet for 8283 Long Island Rd1 The Summit at Lake Norman, Lot 5 House Footprint: See attached plan Building Setbacks: 30' front, 15' side, lake 50' Water Source: Private well Number of Bedrooms/Daily Flow: 4/480 GPD Proposed LTAR: 0.3 GPD/FT2 Proposed System Type: 25% Reduction Proposed Repair System Type: Drip Dispersal Distribution: Pressure Manifold Flow per Tap: 5.48 GPM Tap Size and Material: 'A" SCH 80 System Flow: 27.4 GPM Dosing Volume: 175 gallons Pump Run Time: 6.4 minutes Elevation Head: TBD Friction Head: 8.9' Pressure Head: 2' Total Dynamic Head: TBD Supply Line Length: 480' OF 2" PVC Septic/Pump Tank Size: 1000/1000 gallons Proposed Trench Bottom: 36" (initial), 12" (repair) Line Design Length Actual Length Elevation Pink 1 80' 80' Blue 2 80' 80' T White 3 80' 80' B Orange 4 80' 80' D Yellow 5 80' 80' Initial System: 480' Repair System: 4800 FT2 Pump Tank: TBD House Corner: TBD Benchmark: TBD Comments: Please note this design is only intended for the use of two people per bedroom for a total design flow of 480 GPD and a total occupancy of 8 people. It is intended for residential use only, no commercial use. Please note once a septic system reaches 80% of the designed flow you are reaching the maximum ability of the septic system. Additional occupancy could lead to premature failure of the septic system.