HomeMy WebLinkAboutAUTH-05-2022-171952.TIF „st$' . CATAWBA COUNTY Case# AUfH-05-2022-1 7 1 95 2
/~ I.IlL ,2 Public Health Department Subdivision E J BASS RIVER LOTS
r:� '3 Environmental Health Division PIN# 369804901372
PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 3
1.(..... 2
Site Address: 3192 BASS DR, SHERRILLS FORD NC 28673
Name on Permit: ANGELA HALL
Property Size: Acres 0.48
Directions: Hwy 150 E, left Little Mountain Rd, right Ingleside, left Bass Dr, property on right
Authorization to Construct Permit
Permit Category: Repairs Wastewater Flow: 360 g.p.d.
Type of Facility: Primary Residence-
Basement? Yes Basement Plumbing? Yes Bedrooms: 3
Water Supply: Private Well Maximum Occupants: 6
Soil LTAR: 0.3 g.p.d./ft2
WASTEWATER SYSTEM REQUIREMENTS
Proposed Wastewater System: 50% REDUCTION VERTICAL
System Classification: IIIE- PPBPS GRAVITY DOSED SYSTEM
Septic Tank: New Tank: 1.000 gal Second Septic Tank: 1,000 gal
Pump Tank gal Grease Trap_gal
Dosing Volume gal Pump Specs: GPM @ TDH
Pressure Head ft Draw Down in
Drainfield: Total Area: 600 sq ft Total Trench Length: 200 ft
Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 33 in
Minimum Soil Cover: 6 in Minimum Trench Separation: 8 ft on center
Number of Drain Lines: 7 Trench Width: 2 ft
Distribution: Distribution Box
Pre Treatment: NONE
Additional Specifications:
Keep all parts of new system for repair minimum: 50'from any individual well, 5'from property lines,25' upslope
from home with basement, 50'from lake 760 contour, 10'from power or utility lines. Lines to be installed on
contour. Do not grade drive or fill over system or repair.
Overhead house power line is to be moved and buried prior to installation of system. Power line must be buried
toward existing well and drive to avoid new drain field area. Power line must be minimum 10'from drain field.
System will require a grinder pump from home to a 1000 gallon settling tank in series to a 1000 gallon septic
tank with tee and filter. Insufficient space to set a septic and pump tank below home for basement plumbing due
to 50' lake setback.
System will require 7' lines totalling 200 linear ft of 50%reduction. Lines to be fed equal from distribution box.
7 panels each trench to be installed in accordance with manufacturer guidelines.
See also attached site plan.
Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent 1
proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved, and
may result in failure to approve the initial system installation, or the suspension/revocation of existing permits.
>>>>> Do not install system under wet conditions <<<<<
PROPOSED REPAIR
Repair System Required? Soil LTAR: g.p.d./ft2
Proposed System:
System Classification:
clyemui 05/24/2022 I3:03