Loading...
HomeMy WebLinkAboutAUTH-03-2022-168625.TIF • CATAWBA COUNTY Case# AUTH-03-2022-168625 .t. 1 Public Health Department Subdivision ,,"0 `C Environmental Health Division PIN# 377303406699 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# g 2 Site Address: 4099 OXFORD SCHOOL RD,CATAWBA NC 28609 Name on Permit: STEVEN &MARIA*HULL Property Size: Acres 0.75 Directions: from Catawba take Oxford School Rd/cross 1-40/approx 2 miles on left Authorization to Construct Permit Permit Category: Repairs Wastewater Flow: 36(1 g.p.d. Type of Facility: Primary Residence- Basement? Yes Basement Plumbing? Yes Bedrooms: 3 Water Supply: Public Water Maximum Occupants: 6 Soil LTAR: g.p.d.lft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: OTHER System Classification: IIA-CONV SYSTEM (SINGLE-FAMILY OR 480 GPD OR LESS) Septic Tank: New Tank: 1,000 gal Pump Tank _gal Grease Trap_gal Dosing Volume gal Pump Specs: GPM @ TDH Pressure Head ft Draw Down in Drainfield: Total Area: sq ft Total Trench Length: ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: in Minimum Soil Cover: in Minimum Trench Separation: ft on center Number of Drain Lines: Trench Width: ft Distribution: Drop Box Pre Treatment: NONE Additional Specifications: During initial existing system inspection,it was observed that the existing riser was cracked (lid had fallen inside riser)and top drop box had been removed for some reason. This permit is to fix these two issues. Either replace septic tank with a new 1,000 septic tank or if existing tank is still sound,replace or repair riser. The drop box at the top line must be replaced and have proper fall from the septic tank and to the second line. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains,is not approved,and may result in failure to approve the initial system installation,or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Soil LIAR: g.p.d./ft2 Proposed System: System Classification: ehpereiil 03/13/2023 08:33 0CATAWBA COUNTY Case# AUTH-03-2022-168625 Public Health Department Newton,NC 28658 Subdivision 3 '1PRr: Environmental Health GovernDivisiment on PIN II 377303406699 Drive, LOT# Site Address: 4099 OXFORD SCHOOL RD,CATAWBA NC 28609 Name on Permit: STEVEN &MARIA*HULL Property Size: Acres 0.75 Directions: from Catawba take Oxford School Rd/cross 1-40/approx 2 miles on left The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (I SA NCAC 18A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental I lealth authorization or permit modification.Please notify Environmental Health of this change prior to system installation. , .) ....—......... /11(-.....„: 03/31/2022 Authorized State Agent Permit Issuance]late 3/31/2027 Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of•the Health Department. ehpermit 03/13/2023 08:33 • ,p• . CATAWBA COUNTY Case# AUTH-03-2022-168625 Q -Ilk Public Health Department Subdivision Qlot Environmental Health Division PIN# 377303406699 PO Box 389,25 Government Drive,Newton,NC 28658 1 LOT# Site Address: 4099 OXFORD SCHOOL RD, CATAWBA NC 28609 Name on Permit: STEVEN&MARIA'HULL K Q 1 -�J+Q_ aC� .3/6,53 Property Size: Acres 0.75 1 Directions: from Catawba take Oxford School Rd/cross I-40/approx 2 files on left Authorization to Construct Permit Permit Category: Repairs Wastewater Flow: 360 g.p.d. Type of Facility: Primary Residence- Basement? Yes Basement Plumbing? Yes Bedrooms: 3 Water Supply: Private Well Maximum Occupants: 6 Soil LTAR: g.p.dlft2 WASTEWATER SYSTEM REOUIREMENTS Proposed Wastewater System: OTHER System Classification: IIA-CONV SYSTEM(SINGLE-FAMILY OR 480 GPD OR LESS) Septic Tank: New Tank: 1.000 gal Pump Tank _gal Grease Trap_gal Dosing Volume gal Pump Specs: GPM @ _ TDH Pressure Head ft Draw Down in Dralnfleld: Total Area: sq ft Total Trench Length: ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: in Minimum Soil Cover: in Minimum Trench Separation: ft on center Number of Drain Lines: Trench Width: ft Distribution: Drop Box Pre Treatment: NONE Additional Specifications: During initial existing system inspection, it was observed that the existing riser was cracked(lid had fallen inside riser)and top drop box had been removed for some reason. This permit is to fix these two issues. Either replace septic tank with a new 1,000 septic tank or if existing tank is still sound, replace or repair riser. The drop box at the top line must be replaced and have proper fall from the septic tank and to the second line. See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and may result in failure to approve the initial system installation, or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions <<<<< PROPOSED REPAIR Repair System Required? Soil LTAR: g.p.d.lft2 Proposed System: System Classification: elq tmnit 03/31/2022 15:57 4415 CATAWBA COUNTY Case# AUTH-03-2022-168625 i• IPS Public Health Department Subdivision d • Environmental Health Division , PIN# 377303406699 - : . �1 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# Site Address: 4099 OXFORD SCHOOL RD, CATAWBA NC 28609 Name on Permit: STEVEN &MARIA*HULL Property Size: Acres 0.75 Directions: from Catawba take Oxford School Rd/cross 1-40/approx 2 miles on left The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rule.tfor Sewage Treatment and Disposal Systems' (15A NCAC l 8A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. 17 , 03/31/2022 Authorized State Agent Permit Issuance Date 3/31/2027 Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department. el,pemtit 03/31/2022 15:57