HomeMy WebLinkAboutAUTH-03-2022-167573.TIF \ CATAWBA COUNTY Case# AUTH 03 2022-167573 F- t Public Health Department Subdivision GABRIEL ACRES �� Environmental Health Division PIN# 461601478651 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 14&15 Site Address: 8491 SYLVAN DR, TERRELL NC 28682 p,6pR../D3 / /(��y /0 1 Name on Permit: *WHC CONSTRUCTION INC Property Size: Acres 1 Directions: Kiser Island Rd right on sylvan property is at the end of cul del sac on the left Authorization to Construct Permit Permit Category: Expansion Wastewater Flow: 480 g.p.d. Type of Facility: Primary Residence- Basement? No Basement Plumbing? No Bedrooms: 4 Water Supply: Private Well Maximum Occupants: 8 Soil LTAR: 0.25 g.p.d./ft2 WASTEWATER SYSTEM REQUIREMENTS Proposed Wastewater System: 50%REDUCTION VERTICAL System Classification: IIIB-SYSTEM W/SINGLE EFFLUENT PUMP Septic Tank: New Tank: 1,500 gal Pump Tank 1.500 gal Grease Trap_gal Dosing Volume 266 gal Pump Specs: 30.4 GPM @ 12.4 TDH Pressure Head 2 ft Draw Down 9'5 in Drainfield: Total Area: 960 sq ft Total Trench Length: 320 ft Aggregate Depth: in Maximum Trench Depth on Downhill Sidewall: 36 in Minimum Soil Cover: 6 in Minimum Trench Separation: 8 ft on center Number of Drain Lines: 4 Trench Width: 2 ft Distribution: Pressure Manifold Pre Treatment: NONE Pump Required ***** Operator Required Additional Specifications: *Do not cut,drive, fill, or grade over septic or repair areas. *Septic system must be 10 ft from property lines, 100 ft from the well on site, 5 ft from building foundations and appurtenances, and out of right-of-ways and easements. *Install a 1,500 gallon septic tank(risers required if top of tank is greater than 6 inches below land surface), and a 1,500 gallon pump tank with risers. *Existing septic tank must be pumped out, crushed, and filled in with soil. *Pump tank will pump to a pressure manifold with 4 taps. Four sch 40 1/2'taps feeding lines 1, 2, 3, and 4. *Install 320 linear feet of vertical PPBPS system, proposed 4 lines total. *Laid out proposed system and repair in the field. Initial system will utilize the bottom white(172 ft)and red(16 0 ft)flagged lines. *These 2 lines will be split in half and be center fed via pressure manifold. *Lines 1 and 2(white line)are 82 ft long and will have 19 panels per line. Lines 3 and 4(red line)are 78 ft long and will have 18 panels per line for a total of 74 panels. *Final grade of septic area must shed surface water off and away from system. *All gutter drains must be routed away from the septic system. ehpcnnit 03/18/2022 11:35 • $: CATAWBACOUNTY Case# AUTH-03-2022-167573 r_T " Public Health Department Subdivision GABRIEL ACRES < r:-,) '"l Environmental Health Division PIN# 461601478651 PO Box 389,25 Government Drive,Newton,NC 28658 LOT# 14&15 1, w Site Address: 8491 SYLVAN DR,TERRELL NC 28682 Name on Permit: *WHC CONSTRUCTION INC Property Size: Acres 1 Directions: Kiser Island Rd right on sylvan property is at the end of cul del sac on the left See also attached site plan. Landscaping or other site alterations that potentially divert groundwater or surface water toward the septic system, or prevent proper drainage away from the septic system, including the direction of gutter flows or foundation drains, is not approved,and may result in failure to approve the initial system installation,or the suspension/revocation of existing permits. >>>>> Do not install system under wet conditions<<<<< PROPOSED REPAIR Repair System Required? Required Soil LTAR: 0.25 g.p.d./ft2 Proposed System: 50%REDUCTION VERTICAL System Classification: IVA-ANY SYSTEM WITH LPP DISTRIBUTION Pump Required ***** Operator Required The issuance of this permit by the Health Department does not guarantee the issuance of other permits. It is the responsibility of the applicant /property owner to insure that all Catawba County Planning/Zoning and Building Inspections requirements are met. This Authorization to Construct Permit is subject to revocation if the site plan,plat or the intended use changes,or if site conditions are altered. The Authorization to Construct Permit is not affected by a change in ownership of the property. This permit was issued in compliance with the provisions of the North Carolina'Laws and Rules for Sewage Treatment and Disposal Systems' (I 5A NCAC I8A.1900). Neither Catawba County nor the Environmental Health Specialist warrants that the septic tank system will continue to function satisfactorily for any given period of time. Any permit issued for a conventional system may be used for an accepted system without Environmental Health authorization or permit modification.Please notify Environmental Health of this change prior to system installation. 03/15/2022 Authorized State Agent Permit Issuance Date 3/15/2027 Permit Expiration Date No grading or construction activity is allowed in areas designated for system and repair without approval of the Health Department. L;Iq)enmit 03/15/2022 14:09