HomeMy WebLinkAboutAUTH-10-2020-139814.tif A f3Iq Operator Responsible for Care (O.R.C.) LE. ,,J -,,,f „,„,,.;:i `WASTEWATER Jarrid Lentz - Certified Subsurface Operator License #999423 www.lentzwastewater.corn Date Maintenance Contract Report 04/15/2022 General Information Name Address County Contract Expiration Date Sarah Smyre/Wind and Water 3844 Gordon Street Catawba 06/09/2022 Development Solid Accumulation Levels SEPTIC TANK PUMP TANK Septic Tank Size Percentage of Solids to Liquid Waste Pump Tank Size Percent of Solids to Liquid Waste 1000 gallon 5,9 1000 gallon 0 Inlet Scum Inlet Sludge Outlet Scum Outlet Sludge Scum Sludge 0.000000 3 0 0 0 0 Does the septic tank need to be pumped? Does the Pump Tank Need to be Pumped? No Pig Collection System / Septic Tank Description Condition Notes Tank has risers/ is accessible Yes Risers/ lids in good condition Yes Free of infiltration, surface water diverted Yes Free from Odors Yes Sanitary tee and filter in good condition/Cleaned Yes Today Effluent pipe at proper angle/Water level at proper No Sanitary tee is at an upwards angle which causes water level to be level higher in the tank than normal Effluent Dosing System / Pump Tank Description Condition Notes Tank risers accessible Yes Riser is not 6" above surface grade, mulch could fall into tank and cause pump to fail Free of infiltration, surface water diverted No 12"x 24" Ez-Set riser on effluent pump tank is broken, allows surface water to infiltrate system Control Panel and components in good condition/ Marginal Nema 4 box is 4" above surface grade, Alarm is 9" above surface sealed grade, both should be a minimum of 12" above surface grade Filter in good condition &Cleaned today Not Applicable System does not have an in-line effluent filter and is not required to have one High water alarm operating properly Yes Floats, float tree/hangers, pipes, valves, etc in good Yes condition and functioning Pump is installed on block or raised platform Yes Ground Absorption Field / Drain Field N. Operator Responsible for Care (O.R.C.) 4 lei � ��.�x . Jarrid Lentz - Certified Subsurface Operator WASTEWATER License #999423 www.lentzwastewater.com Description Condition Notes Free of effluent surfacing Yes Surface water diverted/ Field free of settled or low Yes areas Protected from traffic Yes Repair areas reserved, if required Yes Line cover and vegetation maintained properly and Yes protected from traffic Laterals flushed/free of solids Yes Turn-ups, clean-outs, valves located and protected/ Yes working properly Pressure Head !of Lines Design Head(Inches) Adjusted Head(Inches) 3 24 24 GPM Design GPM Actual GPM Percent Efficiency 0 SO 0.00 Notes Percent efficiency will be calculated at second visit. Summary & Recommendations Septic Tank Percent of Solids Pump Tank Percent of Solids 5.9 0 [ i SEPTIC TANK NEEDS TO BE PUMPED (Percent of Solids in tank is >330/0 ) Li PUMP TANK NEEDS TO BE PUMPED (Percent of Solids in tank is > 0% ) CONTACT LENTZ SEPTIC TO SCHEDULE PUMPING 704-876-1834 Summary/Recommendations *Correcting angle of Sanitary Tee, Sanitary tee is at an upwards angle which causes water level to be higher in the tank than normal *Replacing broken 12" x 24" Ez-Set riser section on effluent pump tank ./ ,-. Operator Responsible for Care (O.R.C.) g. Jarrid Lentz - Certified Subsurface Operator i6 4&Mi1 41.E WASTE ATER License #999423 www.lentzwastewater.com *Removing mulch so Nema 4 and alarm boxes 12" above surface grade *Removing mulch so riser on effluent pump tank is a minimum of 6" above surface grade Garbage disposals are not recommended for Type IV systems Recommend disconnecting garbage disposal, if applicable Ima•es-,•4'.-..'•-,.i._.,:,.-:"i"„i'..1;,Al-.-...d."..,+..";.%.2ii,.,,.-.'-‘'-.,......,4-•"._,••;•;••"i:;iw;.'i4t..s•.e4.-.4.'•:.7,*.s.i....e..0.:s.1"-4;i'•.l.••-.s:,,'1:,i•.-%,4 t,*0,..:I.-C...•_..a.,r.-a4-1J #• .. ,,,r. ,.• rr .Ivttfk.5-.,.4"^.,.:-•;,--.,,..,,,.t,._.fr,,...-°.' •, };-:,: ,,.,.-,'._.1t Ju s ` :max �" i f 1r ,k , , , "t-- r t T %''' c• d'v �j r, "C. '' '', y• ad - }fir .. _ti. ` 1 --4 �. *•%:-..1‘-tft..,T, $ .;:t1 .1 s ..;,-1,.. 1.- A% .-,;,,,to .. .:, „ . • ._ ..• ...N.., .. • tt -.... • ...._::,_ 1 .1.\_ ..,:.• . 1:4 • . .., . ........ .. ,... . . • . p:.: a•n I t ,.424,0‘, • .4` . tTlt_ • f.t. try t •i a• •..t'_- 1. �. •riS- - •++ 4. �I a r•c ry: �,z,F` „iY ?: ,. _ 1t pJ 1 y�, w h 3r -.• Y r.� } j' y �. .. �V Q� Y +�ri'1_`4 •. 4��a .} r,+? r t of `q ; .h •r tiy,� ,$ k>..h • t. +' S 1 . ' 5 a�' !+ 41,_..e..- _ y + 1 ' h`—. ..t Ir 11 t• '�y•' t. �..R' i- ,•3 7'..•. . .{+L LL _ "'a{ • ,,ttia liti ......i -. - .-. ':-':•-•--..t—..•.• ;` i+t}o-.. "' ,•:t1•-•:'`...�`+4` r:i�_ ... •r�•w.n..:� "., .4n�. i:,,�.,,r�.'::?. ; [ I8t yy 1 • •' 'A"•-14 . ."�„ �Y011 y ' ...,S I.4.,tip a '•.:i('r.4�'• w•• a4� 0,,;54 ,r p . • ye 41 ` ,..{'„, --4,-„if.,....,,,, .','i.' +'L , Sr b �� ; V It'll! •"fir, '''1- -Alt.: ►/ .-- 1i,.,y„.*,4 •,.'* .. 4 A.e rrl l' t i 4.V V'�4 • ., y r' i •`'•.4-,w f.,r. ,, 1-�'i^ •t'i �'' - T 5.• •r ,pit . +�{ •;•tiTr"r► ��i: t •5��1.► ai .. '', tiff Iv• ;':!••" f°t..T '. !•f(.'".'• er., 4 • b� .. r 1 - 1 `I. 1. . :..1:%`.;.;I .p.i i;, i3 i 1 Ci-:165002.901t:99J r� _ Operator Responsible for Care (O.R.C.) Aliz' ` � Jarrid Lentz - Certified Subsurface Operator Ir °WASTEWATER License #999423 www.Ientzwastewater.com 3 y i 4 • .'1 ; f ti q f*'''',Va 'fv i is 6. z 0 ':,f,,lji. r t ..V.: Y 1 1 M Date 04/15/2022