Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AUTH-08-2020-137492
lAOWA The clear leader. AQWA Inc. 2604 Willis Court,Wilson, NC 27896 A - 13/1/1a Phone: 252-243-7693—Email: aqwatammysanders©gmail.com Customer Name: Bray Date of Inspection: 10/13/2022 Address: Bray-1080 25th Ave Drive N,Hickory,NC 28601 Arrival Time: 11:30 AM System AX ID: AX-152186 County: Catawba Departure Time: 01:35 PM Permit No. Inspection and Maintenance Checklist -AX20 (1, 2, or 3)with or without UV and LPP Dispersal Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 0 Scum 6 Sludge Scum Sludge Tank 1 Outlet Readings Tank 2 Outlet Readings 0 Scum 3 Sludge Scum Sludge ..�.....nirxxx»v!_ .t. ..l�m.�.4..�k .. ,tw ,� •a Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recircular Pumps Recirculation Pump 1 Pump 1 Timer Settings Pump 2 Timer Settings 0.3 Dose 19.7 Rest Dose Rest Pump 1-Counters and Elapsed Time Meters Pump 2-Counters and Elapsed Time Meters 20147 CT 104.8 ETM CT ETM Verify Conduit Seal: None Seen AX20 Treatment Pod(s)Inspection AX Treatment Pod(S) P01 Inspect for Ponding or Bridging: None Check and Record Squirt Height: 3 ft Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record Squirt Height: 3 ft Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned Inspection and Maintenance Checklist-AX20 (1, 2, or 3)with or without UV and LPP Dispersal Recirculation Tank Inspection Verify Inlet Flow, No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 2 Sludge 0 Scum 0 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Visually Check RSV and Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Clean Biotube/Pump Vault Fitter Cartridge: Cleaned Verify Neat V rap of Float and Pump Cords: Checked Inspect Biotube/Pump Vault Filter Cartridge: Ok Verify Conduit Seal: Verified Pull Pump and Clean Screen: Cleaned Verify No Leaking In Piping or Flex Hoses: None Seen Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 UV Disinfectant Unit Inspectfort 'UV I UV2 After Disconnecting Power,Clean or Replace Bulb As Needed Replaced Flush Hosing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Field Dosing Tank Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 0 Sludge 0 Scum 0 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: 26.2 Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified Current Delivery Rate: 26.6 Pump 1 ETM: 37 Current Pump Efficiency: 101 Pumpt 1 CT: 194 Pump 1 ETM Last Inspection: 21.3 Daily Average Flow GPD From Last Inspection: 149.2 LPP Drainfield Areas Mowed and Clear of Obstruction: Yes Area Free of Ponding or Surface Effluent: Yes Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly Flush Laterals: No turnups to laterals exist Set and Record Head Pressure N/A Returned Valves and Control Panel to Proper Settings: Done Panel communication line needs repaired to be able to monitor system status Control Panel Communication Checked: and alarms.There is no clip on the line to connect to any of the equipment. Inspection Notes Removed laterals from treatment POD and cleaned textiles. Paul Smith rJ� A— Operator Operator Signature AQWA The clear leacer AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693— Email: agwatammysanders@gmail.com Customer Name: Bray Date of Inspection: 4/28/2022 Address: Bray-1080 25th Ave Drive N,Hickory,NC 28601 Arrival Time: 07:30 AM System AX ID: AX-152186 County: Catawba Departure Time: 08:45 AM Permit No. Inspection and Maintenance Checklist-AX20(1, 2, or 3)with or without UV and LPP Dispersal Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 0 Scum 6 Sludge Scum Sludge Tank 1 Outlet Readings Tank 2 Outlet Readings 0 Scum 6 Sludge Scum Sludge Clean Effluent Fitter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recircular Pumps Recirculation Pump 1 Pump 1 Timer Settings Pump 2 Timer Settings 0.3 Dose 19.7 Rest Dose Rest Pump 1-Counters and Elapsed Time Meters Pump 2-Counters and Elapsed Time Meters 13184 CT 68.1 ETM CT ETM Verify Conduit Seal: None Seen AX20 Treatment Pod(s)Inspection AX Treatment Pod(S) P01 Inspect for Ponding or Bridging: None Check and Record Squirt Height: 3 ft Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record Squirt Height: 3 ft ,Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned Inspection and Maintenance Checklist-AX2O (1, 2, or 3)with or without UV and LPP Dispersal Recirculation Tank Inspection Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 4 Sludge 0 Scum 4 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Visually Check RSV and Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Clean Biotube/Pump Vault Filter Cartridge: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Inspect Biotube/Pump Vault Filter Cartridge: Ok Verify Conduit Seal: Verified • Pull Pump and Clean Screen: Cleaned Verify No Leaking In Piping or Flex Hoses: None Seen Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 u1 After Disconnecting Power,Clean or Replace Bulb As Needed: Cleaned Flush Hosing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Field Dosing Tank Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 1 Sludge 0 Scum 0 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: 26.2 Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified Current Delivery Rate: 26.3 Pump 1 ETM: 21.3 Current Pump Efficiency: 100 Pumpt 1 CT: 120 Pump 1 ETM Last Inspection: 2.9 Daily Average Flow GPD From Last Inspection: 171 LPP Drainfield Areas Mowed and Clear of Obstruction: Yes Area Free of Ponding or Surface Effluent: Yes Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly Flush Laterals: Flushed Set and Record Head Pressure N/A Returned Valves and Control Panel to Proper Settings: Done Line coming into panel.Needs clip on end of communication line to connect to panel equipment.We cannot monitor the system for alarms with Control Panel Communication Checked: communication established to the control panel line. Inspection Notes 69.25-73=3.75x21=76.75/3=26.3 Installer came since last inspection and made repair to RSV;however,it appears that it has tilted again(not as severe),but tilted nonetheless. p Q Chad Allen �/ t 1.L Operator Operator Signature ek, A0,WA" Thr,:P Iracer AQrt,Wilson, 4 ,)37,1q . 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693 — Email: agwatammysanders@gmail.com Customer Name: Bray Date of Inspection: 4/20/2023 Address: Bray-1080 25th Ave Drive N,Hickory,NC 28601 Arrival Time: 02:15 PM System AX ID AX-152186 County: Catawba Departure Time: 04 10 PM Permit No. Inspection and Maintenance Checklist-AX20 (1, 2. or 3)with or without UV and LPP Dispersal Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 0 Scum 10 Sludge Scum Sludge Tank 1 Outlet Readings Tank 2 Outlet Readings 0 Scum 8 Sludge Scum Sludge PicUonQuestions. Tank 1 Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recircular Pumps Recirculation Pump 1 Pump 1 Timer Settings Pump 2 Timer Settings 0.3 Dose 19.7 Rest Dose Rest Pump 1-Counters and Elapsed Time Meters Pump 2-Counters and Elapsed Time Meters 25510 CT 133.1 ETM CT ETM Verify Conduit Seal: None Seen AX20 Treatment Pod(s)Inspection AX Treatment Pod(S) P01 Pod Inspection Pod.1 Pod 2 Pod 3 Pod 4 Inspect for Ponding or Bridging None Check and Record Squirt Height: 3 ft Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record Squirt Height: 3 ft Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned II Ali 1' lAGWA The clear leader. AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693— Email: aqwatammysanders@gmail.com Customer Name: Bray Date of Inspection: 8/31/2023 Address: Bray-1080 25th Ave Drive N,Hickory,NC 28601 Arrival Time: 10:45AM System AX ID: AX-152186 County: Catawba Departure Time: 01:30 PM Permit No. Inspection and Maintenance Checklist-AX20 (1, 2, or 3)with or without UV and LPP Dispersal Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 0 Scum 14 Sludge Scum Sl..dge Tank 1 Outlet Readings Tank 2 Outlet Readings 0 Scum 10 Sludge Scum SLage 1 Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: Cannot see inlet pipe Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recircular Pumps Recirculation Pump 1 Pump 1 Timer Settings Pump 2 Timer Settings 0.4 Dose 19.6 Rest Dose Rest Pump 1-Counters and Elapsed Time Meters Pump 2-Counters and Elapsed Time Meters 28909 CT 150.6 ETM CT ETM Verify Conduit Seal: None Seen AX20 Treatment Pod(s)Inspection AX Treatment Pod(S) POt Inspect for Ponding or Bridging: None Check and Record Squirt Height: 3 ft Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record Squirt Height: 3 ft Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned . Y Inspection and Maintenance Checklist-AX20(1, 2, or 3)with or without UV and LPP Dispersal Recirculation Tank Inspection Verify Inlet Flow. No Inflow Inspect Liquid Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 8 Sludge 0 Scum 6 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Visually Check RSV and Liquid Level: Normal Verify Audible Alarm Works for High Water float. Works Properly Clean Biotube/Pump Vault Fitter Cartridge: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Inspect Biotube/Pump Vault Fitter Cartridge: Ok Verify Conduit Seal: Verified Pull Pump and Clean Screen: Cleaned Verify No Leaking In Piping or Flex Hoses: None Seen Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 y t i�_�•Ii U r I E 4 f' r T.�"'S{�i` f r. u. o. .w t F, �� y..u. Y r�r`�, r3+Egq�.�'R:s%.:^arow.a- a�._.ra.wz'�:',: _ Yam°' . After Disconnecting Power,Clean or Replace Bulb As Needed Cleaned Flush Hosing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Field Dosing Tank Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings' Outlet Readings: 0 Scum 0 Sludge 0 Scum 1 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: 26.2 Verify All Floats Work. Operating Properly Verify Conduit Seal: Verified Current Delivery Rate: 17.5 Pump 1 ETM: 71.8 Current Pump Efficiency: 67 Pumpt 1 CT 332 Pump 1 ETM Last Inspection: 58.2 Daily Average Flow GPD From Last Inspection: 107.4 LPP Drainfleid Areas Mowed and Clear of Obstruction: Yes Area Free of Ponding or Surface Effluent Yes Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly Flush Laterals Flushed Set and Record Head Pressure N/A Returned Valves and Control Panel to Proper Settings: Done Panel communication line needs repaired.Internet line to lantronix has no Control Panel Communication Checked: connector.Lack of alarm communication is a permit violation. Inspection Notes Cut 1 inch from between RSV and float cage to improve flow of recirculation pumping and keep rsv from low level alarming.68.75-71.25=2.5x21=52.5.3 Paul Smith Operator Operator Signature OWA The cleat leader. AQWA Inc. 1908 Baldree Road S,Wilson, NC 27893 Phone: 252-243-7693— Email: aqwatammysanders@gmail.com Customer Name: Bray Date of Inspection: 7/2/2025 Address: Bray-1080 25th Ave Drive N,Hickory,NC 28601 Arrival Time: 01:50 PM System AX ID: AX-152186 County: Catawba Departure Time: 03:30 PM Permit No. Inspection and Maintenance Checklist-AX20 (1, 2, or 3)with or without UV and LPP Dispersal Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 1 Scum 8 Sludge Scum Sludge Tank 1 Outlet Readings Tank 2 Outlet Readings 0 Scum 10 Sludge Scum Sludge Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recircular Pumps Recirculation Pump 1 Pump 1 Timer Settings Pump 2 Timer Settings 0.3 Dose 19.7 Rest Dose Rest Pump 1-Counters and Elapsed Time Meters Pump 2-Counters and Elapsed Time Meters 53325 CT 277.3 ETM CT ETM Verify Conduit Seal: None Seen AX20 Treatment Pod(s)Inspection AX Treatment Pod(S) P01 Pod Inspection Pod 1 Pod 2 Pod 3 Pod 4 Inspect for Ponding or Bridging None Check and Record Squirt Height: 3 ft Verify Orifice Position and Assess for Clogging: Ok Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record Squirt Height: 3 ft Flush Pod Throroughly: Done Inspect and Clean Vents: Vents Clear Inspection and Maintenance Checklist-AX20(1, 2, or 3)with or without UV and LPP Dispersal Recirculation Tank Inspection Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 3 Sludge 0 Scum 3 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Visually Check RSV and Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Clean Biotube/Pump Vault Filter Cartridge: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Inspect Biotube/Pump Vault Fitter Cartridge: Need Replacing Verify Conduit Seal: Verified Pull Pump and Clean Screen: Not Necessary Verify No Leaking In Piping or Flex Hoses: None Seen Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 UV Disinfectant Unit Inspection UV 1 UV2 After Disconnecting Power,Clean or Replace Bulb As Needed: Cleaned Flush Hosing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Field Dosing Tank Inspection Inspect for Tank/Riser Leakage: None Seen Turbidity Reading: 0.33 Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 0 Sludge 0 Scum 1 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: 26.2 Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified Current Delivery Rate: 35 Pump 1 ETM: 133.1 Current Pump Efficiency: 133 Pumpt 1 CT: 650 Pump 1 ETM Last Inspection: 112.8 Daily Average Flow GPD From Last Inspection: 85.9 LPP Drainfield Areas Mowed and Clear of Obstruction: Yes Area Free of Ponding or Surface Effluent: Yes Curtain Drains,Ditches,Swales Functioning Properly: Yes Check Hardware: Functioning Properly Flush Laterals: Flushed Set and Record Head Pressure 2 ft Returned Valves and Control Panel to Proper Settings: Done Control Panel Communication Checked: No cat five connector on intemet line in panel.Unable to call in. Inspection Notes P1 73-78=5'x21-3+35/26.2=133 Christopher Sanders V " Operator Operator Signature