HomeMy WebLinkAboutCBPR-2-10-3790 Harry M. Arndt Middle additions & renovations from architect.tif j I - CBSA Architects I Architecture ■ Planning ■ Interieir 13euigil ( Y O Box 1239 1 Hickory, North Carolina 26603 ( i 5 June 25, 2010 Mr. Jeffrey Hinkle Code Official Field Supervisor Catawba County Building Services 76 North Center Street Hickory, NC 28601 i RE: Catawba County Schools Harry M. Arndt Middle — Additions /Renovations Reference # CBPR -2 -10 -3790 Dear Jeffery, This letter is confirm that the concrete masonry units that will be used on the above mentioned project for 2 hr walls will comply with the building code. 1. Table 720.1(2) Rated Fire - Resistance Periods for Various Wall and Partitions lists Concrete Masonry Units (Expanded clay, shale or slate require a minimum finished thickness face to face of 3.6" for a two hour rating. 2. Based upon the test data from Froehling & Robertson, Inc. and submitted by the manufacturer, the equivalent thickness for 8' CMU is 3.84 ". 3. Based upon the test data from Froehling & Robertson, Inc. and submitted by the manufacturer, the equivalent thickness for 12" CMU is 5.84 ". 4. The block that has been submitted and is on the site is the expanded clay, shale or slate type I hope this address the concerns about the rating of the block that is on the job site. Please let me know if you have any additional questions or comments. Thank you for your continued assistance with this project. Sincerely, J. Steven Walker, AIA CBSA Architects cc: Steve Demiter, Assistant Superintendent CCS Rick Sain, Construction Manager CCS Ernest Sills, AIA, LEED AP Dean Moore, Cemex Jason Rainey, Mathews Construction Itcatawbabi 062510.docx i i I l