Loading...
HomeMy WebLinkAboutCBPR-4-10-4803 PLAN REVIEW COMMENTS 6-29-2010.bmp .k w rStoreesign S`l V ICCS 6533 Ftying Cloud Drive. Suite 100, Eden Prairie, MN 55344 -3307 Toll Free: 1.800.757.9922 ...... .. ............................................. ............................... www.storedesignservices.com June 29, 2010 Clara Coulbourne Catawba County Plan Review 76 North center Street Hickory, NC. 28601 ccoulbournena,ci.hicko .nc.us C-61'A-- 4 / -/d- 4 eb 3 Re: Proposed Save -a -Lot, 573 SW Hwy 70, Hickory, NC. 28602, Reference # BLDC -4 -10 -6201, PIN #370209253207 Dear Clara Coulbourne, Thank you for sending review comments dated 5/27/2010. We are providing this written response with revisions clouded on the plans as requested. We are also providing the following to address the items listed: Building Review 1. Written response is hereby provided as requested. 2. Noted. No Action required. 3. Noted. 4. All revised drawings have been signed, sealed and dated by design professionals licensed in the state of North Carolina. 5. The Building Code Data on Sheet CS -1 has been revised to indicate the 2009 NC Accessibility Code 6. Required Plumbing Fixture code reference has been revised to be 2009 NCPC Table 403.1. 7. The condenser frame is being placed 6' -9" from the roof edge therefore no guardrails should be necessary. 8. There is a sprinkler riser that covers parts of either side of the existing space with the center not sprinkled as far as we know. A portion of the Save -a -Lot space has sprinklers and part of the space does not. We plan on adding sprinklers to the portion of the Save -a -Lot space that is not sprinkled based on FP -1. So the tenant on one side of Save -a -Lot will have existing sprinklers and the other side will not. We do not know what the plans are for the other tenant space however, we do have a 2 -hour demising wall as noted in the next comment. 9. The fire barrier wall has been noted to be 2 -hour in keyed note 1 as well as on the UL assembly detail on sheet A -5.1. 10. Rest Rooms are part of the Landlord's scope of work which is to be under a different permit. The lease agreement for the tenant fit out includes a requirement that the Landlord provided restrooms are ADA compliant which includes the provision of vertical and horizontal grab bars per ICC / ANSI A117.1 -2003 Section 604.5.1. We will copy the Landlord on this response letter to ensure compliance for what is to be an existing condition for the tenant fit out side of work. 11. The only prep (kitchen) occupancies are Meat Prep (16' x 16' = 256 sq ft) and Produce Prep ( 64 sq ft). The layout for each of these areas is shown on sheet F -1.1. Meat Prep has a 3- compartment sink, hand sink table and wrapper. The Produce area has a 3- compartment sink, hand sink and table. Sheet F -1.1 has been reissued to more clearly label the equipment as requested. 12. The UL fire rating has been updated to specify 2 -hour construction. This portion of work is to be performed by the Landlord under a separate contract from this tenant fit out portion of work. Pagel of 3