Loading...
HomeMy WebLinkAboutAUTH-09-2019-121501.TIF A , w 4.4AO NAM AQWA Inc. A , :J5UI The dear Fader 2604 Willis Court, Wilson, NC 27896 Phone: 252-243-7693— Email: aqwatammysanders@gmail.com Customer Name: Shenoy System: SSD Inspector: Chad Allen Date of Inspection: April 28,2022 Arrival lime: Departure Time: Drip Irrigation Maintenance Checklist Current Readings Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 265 284 2 136 132 Timer 13.1 1.4 0.1 17.53 17.36 Flow Meter: 9370 Previous Inspection Readings Date of Previous Inspection: 2/9/2022 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 0 0 0 3 0 Timer 0 0 0 0.1 0 Flow Meter: 720 Elapsed Calculations Elapsed Days: 77 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 265 264 2 133 132 Timer 13.1 1.4 0.1 17.43 17.36 Total Flow Since Last Visit: 8650 Number of Days: 77 Average Daily Flow: 112.3376623 Spin Filter: Cleaned Filtrate Return Line: Yes Closed Zone Testing Zone 1 Zone 2 Zone 3 Zone 4 Pre Filter(PSI) 60 60 Post Filter(PSI) 58 60 Dose Rate(GPM) 8.1 8.2 Supply PSI 40 58 Return PSI 36 54 Flush Rate GPM 12.1 14.9 Flush Supply PSI 20 20 Flush Return PSI 0 0 Inspection Comments Inspector's Signature r • AOWA The clew leader. AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693- Email: agwatammysanders@gmail.com Customer Name: Shenoy Date of Inspection: 4/28/2022 Address: Shenoy-4260 4th Street Lane NW,Hickory,NC 28601 Arrival lime: 8:30:00 AM System AX ID: AX-153461 Departure Time: 10:25:00 AM County: Catawba Permit No. Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Septic Tank Inspection Tank At Site Tank 1 _ Tank 1 Inlet Readings Tank 2 Inlet Readings 0 Scum 10 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 Scum 10 Sludge Scum Sludge Tank Inspection Questions Tank 1 Tank 2 Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: Cannot see inlet pipe Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recirculation Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 0.8 Dose 10 Rest 9201 CT 124.5 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 8 Dose 80 Rest 265 CT 13.1 ETM Verify Conduit Seal: Verified AX-RT Treatment Pod Inspection u I P G:Ita. _ dFi n,.. cat "904KI i..,rl�tak1t4 �1 '�4h�; s.'.?;'c?i�i� Inspect for Ponding or Bridging: None Check and Record PSI: 4.5 Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record PSI 4.5 Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Recirculation Chamber Inspection Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 3 Sludge 0 Scum 0 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified Ultraviolet Disinfection Unit inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 After Disconnecting Power,Clean or Replace Bulb As Needed: Cleaned Flush Housing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 0 Sludge 0 Scum 0 Sludge VisuaNy Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: 6 Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified Drip Irrigation System Area Inspection Areas Mowed and Clear of Obstruction: Yes Area Free of Ponding or Surface Effluent: Yes Curtain Drains,Ditches,Swales Functioning Property: Yes Return Valves and Control Panel to proper settings Done Control Panel Communication Checked: Panel called in. Inspection Notes Adjusted the dose floats.The way they were set was middle and top float were at the top of the tank.I moved them down but kept the spacing they had. Chad Allen Operator Operators Signature aAOWA AQWA Inc. The clear leader 2604 Willis Court, Wilson, NC 27896 Phone: 252-243-7693 — Email: agwatammysanders@gmail.com Customer Name: Shenoy System: SSD Inspector: Chad Allen Date of Inspection: August 16.2022 Arrival Time: Departure Time: Drip Irrigation Maintenance Checklist Current Readings Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 470 5 4 239 MEM Timer 40.6 2.2.5 0.2 39,46 Flow Meter: 22580 Previous Inspection Readings Date of Previous Inspection: 4/28/2022 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 265 264 2 136 132 Timer 13 1 1.4 0.1 17.53 17.36 Flow Meter: 9370 Elapsed Calculations Elapsed Days: 110 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 205 201 2 103 103 Timer 27.5 1.1 0.1 2193 22.12 Total Flow Since Last Visit: 13210 Number of Days: 110 Average Daily Flow: 120.0909091 Spin Filter: Cleaned Filtrate Return Line: Yes Slightly Open Zone Testing Zone 1 Zone 2 Zone 3 Zone 4 Pre Filter(PSI) 58 58 Post Filter(PSI) 58 58 Dose Rate(GPM) 6 6.2 ■- Supply PSI 48 56 Return PSI 44 50 Flush Rate GPM 12.5 14 Flush Supply PSI 20 22 Flush Return PSI 0 0 Inspection Comments Inspector's Signature AQWA AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693- Email: aqwatammysanders@gmail.com Customer Name: Shenoy Date of Inspection: 0(16,2022 Address: Shenoy-4260 4th Street Lane NW.Hickory,NC 28601 Arrival Time: 10:45.43 AM System AO(ID: AX•153461 Departure Time: 1:20 00 PM County: Catawba Permit No. Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Septic Tank Inspection Tank At Site rank 1 Tank I Inlet Readings Tank 2 Inlet Readings 1 Scum 12 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 Scum tt Sludge Scum Sludge Tank Inspection Questions Tank 1 Clean Effluent Filter Cleaned Check for Influent or Effluent Blockages: Cannot see inlet pipe Inspect Tank/Riser for Leaks. None Seen Control Panel Inspection Check Pump Operates In Manual Mode- Yes Recirculation Pumps Pump 1 Timer Settings Pump t-Counters and Elapsed Time Meters 0 8 Dose 10 _Rest 20357 CT 276.2 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 8 Dose 80 Rest 470 CT 40.6 ETM Verify Conduit Seal Verified AX-RT Treatment Pod Inspection Inspect for Pending or Bridging: None Check and Record PSI: 4.5 Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record PSI 4.5 Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Recirculation Chamber Inspection Verify Inlet Flow Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 3 Sludge 0 Scum 0 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Property Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal- Verified Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 After Disconnecting Power,Clean or Replace Bub As Needed: Replaced Flush Housing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 0 Sludge 0 Scum 0 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Cleaned Delivery Rete at Start Up: B Verify All Floats Work: Operating Properly Verity Conduit Seal: Verified Drip Irrigation System Area Inspection Areas Mowed and Clear of Obstruction: Yes Area Free of Pending or Surface Effluent: Yes Curlew Drains,Ditches,Swales Functioning Properly: Yes Retum Valves and Control Panel to proper settings Done _ Control Panel Communication Checked: Panel called in. Inspection Notes When I arrived the system was completely loaded up.No lights on the board was lit up.Found the fuse on the lop of the board was blown.Replaced with a new slow blow fuse.The lantronics was also not working.Replaced with a new one.System now in normal level and operating correctly. Chad Allen Operator Operators Signature •AQWA The ilea leader. AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693—Email:aqwatammysanders@gmail.com Customer Name: Shenoy Date of Inspection: 10/13/2022 Address: Shenoy-4260 4th Street Lane NW,Hickory,NC 28601 Arrival Time: 1:50:00 PM System AX ID: AX-153461 Departure lime: 3:15:00 PM County: Catawba Permit No. Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 0 Scum 6 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 Scum 3 Sludge Scum Sludge Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recirculation Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 0.8 Dose 10 Rest 27945 CT 379.3 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters Demand Dose Demand Rest 583 CT 55.2 ETM Verify Conduit Seal: Verified AX-RT Treatment Pod Inspection Inspect for Ponding or Bridging: None Check and Record PSI: 4.5 Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record PSI 4.5 Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Recirculation Chamber Inspection Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 1 Sludge 0 Scum 0 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 After Disconnecting Power,Clean or Replace Bulb As Needed: Cleaned Flush Housing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 0 Sludge 0 Scum 0 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: 6 Verify All Floats Work. Operating Properly Verify Conduit Seal: Verified Drip irrigation System Area Inspection Areas Mowed and Clear of Obstruction: Yes Area Free of Ponding or Surface Effluent: Yes Curtain Drains,Ditches,Swales Functioning Properly: Yes Return Valves and Control Panel to proper settings Done Control Panel Communication Checked: Panel called in. Inspection Notes f - Paul Smith Operator Operators Signature aAQWAM AQWA Inc. The clew Irrder 2604 Willis Court, Wilson, NC 27896 Phone: 252-243-7693 — Email: aqwatammysanders@gmail.com Customer Name: Shenoy System: SSD Inspector: Paul Smith Date of Inspection: November 2,2022 Arrival Time: Departure Time: Drip Irrigation Maintenance Checklist Current Readings Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 609 604 8 308 305 Timer 58.6 3.2 0.3 54.21 54.54 Flow Meter: 31190 Previous Inspection Readings Date of Previous Inspection: 8116/2022 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 470 465 4 239 235 Timer 40.6 2.5 0.2 39.46 39.48 Flow Meter: 22580 Elapsed Calculations Elapsed Days: 78 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 139 139 2 69 70 -- Timer 18 0.7 0.1 14.75 15.06 -- Total Flow Since Last Visit: 8610 Number of Days: 78 Average Daily Flow: 110.3846154 Spin Filter: Cleaned Filtrate Return Line: Yes Slightly Open Zone Testing Zone 1 Zone 2 Zone 3 Zone 4 Pre Filter(PSI) 58 58 Post Filter(PSI) 58 58 Dose Rate(GPM) 6.3 6.1 Supply PSI 50 48 Return PSI 48 48 Flush Rate GPM 11.9 12.6 Flush Supply PSI 20 20 Flush Return PSI 0 0 Inspection Comments Inspectors Signature AO A1A AQWA Inc. ' ' /2/51) 1 The clear leader. 2604 Willis Court, Wilson, NC 27896 Phone: 252-243-7693— Email: aqwatammysanders@gmail.com Customer Name: Shenoy System: SSD Inspector: Jeff Cranmer Date of Inspection: June 20,2023 Arrival Time: Departure Time: Drip Irrigation Maintenance Checklist Current Readings Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 963 956 8 485 482 Timer 104.8 5 0.4 92,38 92.38 , Flow Meter: 52570 Previous Inspection Readings Date of Previous Inspection: 11/212022 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 609 604 6 308 305 Timer 58.6 3.2 0.3 54.21 54.54 Flow Meter: 31190 Elapsed Calculations Elapsed Days: 230 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 354 352 2 177 177 Timer 46.2 1.8 0.1 38.17 37.84 Total Flow Since Last Visit: 21380 Number of Days: 230 Average Daily Flow: 92.95652174 Spin Filter: Cleaned Filtrate Return Line: Yes Closed Zone Testing Zone 1 Zone 2 Zone 3 Zone 4 Pre Filter(PSI) 65 65 Post Filter(PSI) 65 65 Dose Rate(GPM) 5.9 5.8 Supply PSI 45 45 Return PSI 45 45 -. Flush Rate GPM 14.8 16.4 Flush Supply PSI 30 20 ■- Flush Return PSI 0 0 Inspection Comments Repaired 2 leaks in zone#2. Inspector's Signature eAo A The clear leader. AQWA Inc. 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693—Email: aqwatammysanders@gmail.com Customer Name: Shenoy Date of Inspection: 6/20/2023 Address: Shenoy-4260 4th Street Lane NW,Hickory,NC 28601 Arrival Time: 12:35:00 PM System AX ID: AX-153461 Departure Time: 2:10:00 PM County: Catawba Permit No. Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 0 Scum 6 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 Scum 4 Sludge Scum Sludge . Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode. Yes Recirculation Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 0.8 Dose 10 Rest 58416 CT 792.2 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 8 Dose 80 Rest 963 CT 104.8 ETM Venfy Conduit Seal: Verified AX-RT Treatment Pod Inspection �a��'"RKA,.-..<,�..'.'X". Inspect for Ponding or Bridging. None Check and Record PSI: 4.5 Verify Orifice Position and Assess for Clogging: Ok Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record PSI 4.5 Flush Pod Throroughly: Done Inspect and Clean Vents: Vents Clear Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Recirculation Chamber Inspection Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 3 Sludge 0 Scum 2 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: Repairs Needed,See Notes Verify Conduit Seal: Verified Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV After Disconnecting Power,Clean or Replace Bulb As Needed: Cleaned Flush Housing Thoroughly: Flushed Retum Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 4 Sludge 0 Scum 5 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: 6 Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified Drip Irrigation System Area Inspection Areas Mowed and Clear of Obstruction Yes Area Free of Ponding or Surface Effluent: Yes Curtain Drains,Ditches,Swales Functioning Properly: Yes Return Valves and Control Panel to proper settings Done Control Panel Communication Checked: Called in Inspection Notes On the recirc pump assembly that goes to filtrate line out of rt had a split female threaded coupling.Could not repair due to not having a orenco union(the filtrate return was shut off so capped line to stop leak)pics in gmail.Will need to return with part for repair. Jeff Cranmer �f Operator Operators Signature Ooo\9 - 13\�o t •AQWA The clear leader. AQWA Inc. 2604 Willis Court,Wilson,NC 27896 Phone:252-243-7693—Email:aqwatammysanders@gmail.com Customer Name: Shenoy Date of Inspection: 4/1/2025 Address: Shenoy-4260 4th Street Lane NW,Hickory,NC 28601 Arrival Time: 2:15:00 PM System AX ID: AX-153461 Departure Time: 5:20:00 PM County: Catawba Permit No. Inspection and Maintenance.Checklist-AX-RT Sub Surface or Surface Drip Dispersal Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank Inlet Readings 0 Scum 4 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 Scum 4 Sludge Scum Sludge Tank Inspection Questions Tank i Tank 2 Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual,Mode: Yes Recirculation Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 0.8 Dose 10 Rest 38160 CT 1896.2 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 8 Dose 80 Rest 1851 CT 209.3 ETM Verify Conduit Seal: Verified AX-RT Treatment Pod Inspection Pod Inspection Pod 1 Inspect for Ponding or Bridging: None Check and Record PSI: 4.5 Verify Orifice Position and Assess for Clogging: Ok Check for Odors: Ok Clean,Brush,Flush Lateral: Done Recheck and Record PSI 4.5 Flush Pod Throroughly: Done Inspect and Clean Vents: Vents Clear Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Recirculation Chamber Inspection Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 2 Sludge 0 Scum 1 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 UV Disinfectant Unit Inspection UV 1 UV2 After Disconnecting Power,Clean or Replace Bulb As Needed: Cleaned Flush Housing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 3 Sludge 0 Scum 4 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: 6 Verify All Floats Work: Operating Properly Verify Conduit Seal: Verified Turbidity: 2.70 Drip Irrigation System Area Inspection Areas Mowed and Clear of Obstruction: Needs Mowing Area Free of Ponding or Surface Effluent: Surfacing Curtain Drains,Ditches,Swales Functioning Properly: Yes Return Valves and Control Panel to proper settings Done Control Panel Communication Checked: Called in Inspection Notes Surfacing water came from leaks found in zone 1 and 2.Leaks fixed,refer to drip inspection for more info. Christopher Sanders QA(1.7? Operator Operators Signature I eAaWA AQWA Inc. The clear leader. 2604 Willis Court,Wilson, NC 27896 Phone: 252-243-7693— Email: aqwatammysanders@gmail.com Customer Name: Shenoy System: SSD Inspector: Christopher Sanders Date of Inspection: April 1,2025 Arrival Time: Departure Time: Drip Irrigation Maintenance Checklist Current Readings 1 I Pump Filter Flush Zone Flush Zone 1 Zone 2, Zone 3 Zone 4 Counter 1851 1838 14 930 926 Timer 209.3 9.7 0.7 186.55 177.09 -- Flow Meter: 113190 Previous Inspection Readings Date of Previous Inspection: 10/24/2024 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3' Zone 4 Counter 1662 1660 12 841 837 Timer 176.6 8.8 0.6 168.53 161.51 Flow Meter: 100660 Elapsed Calculations Elapsed Days: 159 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 189 178 2 89 89 Timer 32.7 0.9 0.1 18.02 15.58 -- Total Flow Since Last Visit: 12530 Number of Days: 159 Average Daily Flow: 78.80503145 Spin Filter: Replaced Filtrate Return Line: Yes Slightly Open Zone Testing Zone 1 Zone 2 - Zone 3 Zone 4 i 'Pre Filter(PSI) � - - 59 -----60 --- Post'Filter(PSI) 51 52 Dose Rate(GPM) 5.7 4.8 Supply PSI 25 32 Return PSI 25 30 Flush Rate GPM 8.7 12.8 Flush Supply PSI 20 20 flush Return PSI ! 0 0 Inspection Comments _ During zone 1 field test,noticed high dose rate of 7.5gpm.Walked field r and found water shooting*out of a torn dripper tubing section.When I found the leak,I also noticed ruts in the ground.Something heavy with wheels has been across the two zones at this site.Drip field is not supposed to have anything heavier than a lawnmower on it.Field has not been managed either,overgrown grass mounds are all over zones although sod or groundcover fails to exist in much of the field.Several sections of dripper tubing are exposed in these zones and all dripper tubing should be a minimum of 6"below grade.Grass was not planted and erosion has exposed roughly 20 areas of tubing in these zones.Zone two had two leaks at the bottom of zone next to lake.Runoff from these leaks could have made it to the lake.Good topsoil needs to be added to exposed tubing areas of 6" depth.Design engineer needs to approve the dirt that is brought in to avoid field failure.Materials used on zone 1 leak was two screw black couplings for dripper tubing.Zone 2 leaks were fixed using one black screw coupling a piece.Total of four couplings used on all three leaks. Additional time beyond prepaid maintenance spent repairing damaged lines. The field is noncompliant with regulatory rules and in permit violation. Pictures emailed. ?X Inspector's Signature eAa A The clear leader. AQWA Inc. 1908 Baldree Rd S,Wilson, NC 27893 Phone: 252-243-7693—Email: aqwatammysanders@gmail.com Customer Name: Shenoy Date of Inspection: 7/16/2025 Address: Shenoy-4260 4th Street Lane NW,Hickory,NC 28601 Arrival Time: 7:30:00 AM System AX ID: AX-153461 Departure Time: 10:30:00 AM County: Catawba Permit No. Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Septic Tank Inspection Tank At Site Tank 1 Tank 1 Inlet Readings Tank 2 Inlet Readings 0 Scum 6 Sludge Scum Sludge Tank 1 Outlet Readings Tank 1 Outlet Readings 0 Scum 4 Sludge Scum Sludge Tank Inspection Ques ': Clean Effluent Filter: Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Pump Operates In Manual Mode: Yes Recirculation Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 0.2 Dose 8 Rest 54889 CT 1962.4 ETM Dose Pumps Pump 1 Timer Settings Pump 1-Counters and Elapsed Time Meters 8 Dose 80 Rest 1981 CT 209.9 ETM Verify Conduit Seal: Verified AX-RT Treatment Pod Inspection Pod Inspection Pod 1 Inspect for Ponding or Bridging: None Check and Record Drawdown Inches Arrival: 4.5 Verify Orifice Position and Assess for Clogging: Cleaned Check for Odors: None Clean,Brush,Flush Lateral: Done Recheck and Record Drawdown Inches Departure: 4.5 Flush Pod Throroughly: Done Inspect and Clean Vents: Cleaned Inspection and Maintenance Checklist-AX-RT Sub Surface or Surface Drip Dispersal Recirculation Chamber Inspection Verify Inlet Flow: No Inflow Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings 0 Scum 1 Sludge 0 Scum 1 Sludge Inspect Tank/Riser for Leakage: None Seen Verify All Floats Work: Operating Properly Pump Sludge to Septic Tank: Not Needed Verify Audible Alarm Works for High Water float: Works Properly Pull Pump and Clean Screen: Cleaned Verify Neat Wrap of Float and Pump Cords: Checked Verify No Leaking In Piping or Flex Hoses: None Seen Verify Conduit Seal: Verified Ultraviolet Disinfection Unit Inspection Does System Have a UV? Yes How Many UV Disinfectant Units Present? UV 1 UV Disinfectant Unit Inspection UV 1 UV2 After Disconnecting Power,Clean or Replace Bulb As Needed: Replaced Flush Housing Thoroughly: Flushed Return Power and Verify Proper Function: Verified Dosing Chamber Inspection Inspect for Tank/Riser Leakage: None Seen Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 1 Sludge 0 Scum 1 Sludge Visually Check Liquid Level: Normal Verify Audible Alarm Works for High Water float: See Notes Verify No Leaks In Piping or Flex Hoses: None Seen Verify Neat Wrap of Float and Pump Cords: Checked Inspect Pump Intake: Ok Delivery Rate at Start Up: 6 Verify All Floats Work: Malfunctioning Floats Verify Conduit Seal: Verified Turbidity: 0.00 Drip Irrigation System Area Inspection Areas Mowed and Clear of Obstruction: Needs Mowing Area Free of Ponding or Surface Effluent: Surfacing Curtain Drains,Ditches,Swales Functioning Properly: Yes Return Valves and Control Panel to proper settings Done Control Panel Communication Checked: Panel called in. Inspection Notes Filtrate return line dogged,cleared line.Dose pump high level/alarm float not working properly,replaced with a blue collar float with 10 ft electrical wire.Dripper tubing in field in about 20 sections are above ground surfacing,not covered with soil.See previous reports regarding this issue. '11211-0i Paul Smith Operator Operators Signature AQWAM AQWA Inc. Thn clear leader 1908 Baldree Road S, Wilson, NC 27893 Phone: 252-243-7693- Email: aqwatammysanders@gmail.com Customer Name: Shenoy System: SSD Inspector: Paul Smith Date of Inspection: July 16,2025 Arrival Time: 7:30:00 AM Departure Time: 10:30:00 AM Drip Irrigation Maintenance Checklist Current Readings Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 1981 1965 17 1003 999 Timer 209.9 10.4 0.8 198.55 192.42 Flow Meter: 121510 Previous Inspection Readings Date of Previous Inspection: 4/1/2025 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 1851 1838 14 930 926 Timer 209.3 9.7 0.7 186.55 177.09 Flow Meter: 113190 Elapsed Calculations Elapsed Days: 106 Pump Filter Flush Zone Flush Zone 1 Zone 2 Zone 3 Zone 4 Counter 130 127 3 73 73 Timer 0.6 0.7 0.1 12 15.33 Total Flow Since Last Visit: 8320 Number of Days: 106 Average Daily Flow: 78.49056604 Spin Filter: Clogged,Replaced Filtrate Return Line: Yes Slightly Open Zone Testing Zone 1 Zone 2 Zone 3 Zone 4 Pre Filter(PSI) 64 64 -_ Post Filter(PSI) 65 65 Dose Rate(GPM) 6 6.1 Supply PSI 50 35 Return PSI 48 34 ■- , Flush Rate GPM 10.1 11.2 Flush Supply PSI 22 18 Flush Return PSI 0 0 Inspection Comments Removed plug from green cap on spin filter due to pressure deforming filter.Spin filter has green cap no plug. Filtrate return line clogged, cleared line.There are still about 20 sections of dripper tubing that are on top of the ground and need soil cover.See previous report details about this. Inspector's Signature