Loading...
HomeMy WebLinkAboutBLDC-3-10-5117 COMcheck 2-2-10.tif s i COMcheck Software Version 3.6.1 Envelope Compliance Certificate 2006 IECC Section 1: Project Information Project Type: New Construction Project Title : Lowe's Food's Kiosk - Hickory Construction Site: Owner /Agent: Designer /Contractor: 1316 2nd St. NE Ricky Long Hickory, NC Lorenz Architecture 101 Cabarrus Ave. E. Suite 200 Concord, NC 28025 704- 793 -9933 Section 2: General Information Building Location (for weather data): Hickory (Catawba), North Carolina Climate Zone: 4a Heating Degree Days (base 65 degrees F): 3728 Cooling Degree Days (base 50 degrees F): 4199 Vertical Glazing / Wall Area Pct.: 8% Activity Tvoefs) Floor Area Office 230 Section 3: Requirements Checklist Envelope PASSES: Design 11 % better than code. i i Climate -Specific Requirements: i Component Name /Description Gross Area Cavity Cont. Proposed Budget or Perimeter R -Value R -Value U- Factor U- Factor Roof 1: All -Wood Joist/Rafter/Truss 230 19.0 17.0 0.028 0.034 Exterior Wall 1: Wood Frame, Any Spacing 268 110 0.0 0.089 0.089 Window 1: Metal Frame:Double Pane, Tinted, SHGC 0.40 20 — — 0.330 0.550 Exterior Wall 2: Wood Frame, Any Spacing 106 13.0 0.0 0.089 0.089 Window 2: Metal Frame:Double Pane, Tinted, SHGC 0.40 29 — — 0.330 0.550 Exterior Wall 3: Wood Frame, Any Spacing 268 13.0 0.0 0.089 0.089 Window 3: Metal Frame:Double Pane, Tinted, SHGC 0.40 12 — — 0.330 0.550 Door 1: Insulated Metal, Swinging 42 — — 0.167 0.700 Exterior Wall 4: Wood Frame, Any Spacing 106 13.0 010 0.089 0.069 Floor 1: Slab- On- Grade:Unheated 67 — — — — i (a) Budget U -factors are used for software basellne calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: z 0 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor - permeable wrapping material installed in accordance with the manufacturer's installation instructions. ❑ 2. Windows, doors, and skylights certified as meeting leakage requirements. I] 3. Component R- values & U -factors labeled as certified. r Cl 4. Insulation installed according to manufacturer's Instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R -value without compressing the Insulation. t Project Title: Lowe's Food's Klosk - Hickory Report date: 02/02/10 Data filename: \ \Server2009 \data (s) \Projects A -Z\DR Mozeley - Lowes Kiosk - Hickory 09072 \Design Documents \CD'S \Current\Kiosk - Hickory.cck - Page 1 of 2 ( 0 5. No roof insulation is installed on a suspended ceiling with removable ceiling panels. 6. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized dampers. 7. Cargo doors and loading dock doors are weather sealed. L) 8. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. ) 9. Building entrance doors have a vestibule equipped with closing devices. Exceptions. Building entrances with revolving doors. Doors that open directly from a space less than 3000 sq. ft. in area. ❑ 10. Vapor retarder installed. Section 4: Compliance Statement Compliance Statement The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 20061ECC requirements in COMcheck Version 3.6.1 and to comply with tImandatory requirements in t Requirements Checklist. t N me "TIU8 u Date 1 4FJJQFAOF r 4 E I 4 4 y Project Title: Lowe's Food's Kiosk - Hickory Report date: 02/02/10 Data filename: \ \Server2009 \data (s) \Projects A -Z\DR Mozeley - Lowes Kiosk - Hickory 09072\Design Documents \CD'S \Current\Kiosk - Hickory.cck - Page 2 of 2 a