COMcheck Software Version 3.6.1
Envelope Compliance Certificate
2006 IECC
Section 1: Project Information
Project Type: New Construction
Project Title : Lowe's Food's Kiosk - Hickory
Construction Site: Owner /Agent: Designer /Contractor:
1316 2nd St. NE Ricky Long
Hickory, NC Lorenz Architecture
101 Cabarrus Ave. E.
Suite 200
Concord, NC 28025
704- 793 -9933
Section 2: General Information
Building Location (for weather data): Hickory (Catawba), North Carolina
Climate Zone: 4a
Heating Degree Days (base 65 degrees F): 3728
Cooling Degree Days (base 50 degrees F): 4199
Vertical Glazing / Wall Area Pct.: 8%
Activity Tvoefs) Floor Area
Office 230
Section 3: Requirements Checklist
Envelope PASSES: Design 11 % better than code.
i
i
Climate -Specific Requirements:
i
Component Name /Description Gross Area Cavity Cont. Proposed Budget
or Perimeter R -Value R -Value U- Factor U- Factor
Roof 1: All -Wood Joist/Rafter/Truss 230 19.0 17.0 0.028 0.034
Exterior Wall 1: Wood Frame, Any Spacing 268 110 0.0 0.089 0.089
Window 1: Metal Frame:Double Pane, Tinted, SHGC 0.40 20 — — 0.330 0.550
Exterior Wall 2: Wood Frame, Any Spacing 106 13.0 0.0 0.089 0.089
Window 2: Metal Frame:Double Pane, Tinted, SHGC 0.40 29 — — 0.330 0.550
Exterior Wall 3: Wood Frame, Any Spacing 268 13.0 0.0 0.089 0.089
Window 3: Metal Frame:Double Pane, Tinted, SHGC 0.40 12 — — 0.330 0.550
Door 1: Insulated Metal, Swinging 42 — — 0.167 0.700
Exterior Wall 4: Wood Frame, Any Spacing 106 13.0 010 0.089 0.069
Floor 1: Slab- On- Grade:Unheated 67 — — — —
i
(a) Budget U -factors are used for software basellne calculations ONLY, and are not code requirements.
Air Leakage, Component Certification, and Vapor Retarder Requirements: z
0 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor - permeable wrapping material installed in accordance
with the manufacturer's installation instructions.
❑ 2. Windows, doors, and skylights certified as meeting leakage requirements.
I] 3. Component R- values & U -factors labeled as certified.
r
Cl 4. Insulation installed according to manufacturer's Instructions, in substantial contact with the surface being insulated, and in a manner that
achieves the rated R -value without compressing the Insulation. t
Project Title: Lowe's Food's Klosk - Hickory Report date: 02/02/10
Data filename: \ \Server2009 \data (s) \Projects A -Z\DR Mozeley - Lowes Kiosk - Hickory 09072 \Design Documents \CD'S \Current\Kiosk -
Hickory.cck - Page 1 of 2
(
0 5. No roof insulation is installed on a suspended ceiling with removable ceiling panels.
6. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized
dampers.
7. Cargo doors and loading dock doors are weather sealed.
L) 8. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly with a
0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. )
9. Building entrance doors have a vestibule equipped with closing devices.
Exceptions.
Building entrances with revolving doors.
Doors that open directly from a space less than 3000 sq. ft. in area.
❑ 10. Vapor retarder installed.
Section 4: Compliance Statement
Compliance Statement The proposed envelope design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 20061ECC
requirements in COMcheck Version 3.6.1 and to comply with tImandatory requirements in t Requirements Checklist. t
N me "TIU8
u Date
1 4FJJQFAOF
r
4
E
I
4
4
y
Project Title: Lowe's Food's Kiosk - Hickory Report date: 02/02/10
Data filename: \ \Server2009 \data (s) \Projects A -Z\DR Mozeley - Lowes Kiosk - Hickory 09072\Design Documents \CD'S \Current\Kiosk -
Hickory.cck - Page 2 of 2
a